HP 4400 HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 67
Fabric OS 6.4.0a fixes
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Closed defect summary Solution Switch does not broadcast Unsolicited FIP Discovery Advertisements. If the CNA expects UAs from the FCF even if the solicited advertisement had the "D" bit set, it will logout of the FCF after about 20 seconds. Fixed in Fabric OS 6.4.0 Zone-1004 messages seen with port changing from Hard to Session based zoning. When trapped frames get forwarded to the NameServer for zone check, the switch generates a zone-1004 for all trapped frames, whether the port is already in session or hard-based zoning, due to the port being momentarily switched to hard-based zoning when processing the ELS frame that is forwarded to the NS for zone check. Fixed in Fabric OS 6.4.0 Fabric OS 6.4.0a fixes Table 10 lists defects closed in the Fabric OS 6.4.0a firmware release. Table 10 Fabric OS 6.4.0a closed defects Closed defect summary Solution As a result of firmwaredownload, systemverifcation test, or blade insertion, occasionally 10/24 FCoE blade may turn faulty 21. Fixed in Fabric OS 6.4.0a Workaround prior to upgrade: Use slotpoweroff/on the FCoE10-24 to clear the faulty state. In FICON environment, FRU events are not generated on the operator's Fixed in Fabric OS 6.4.0a console for removal or insertion. Rare corner case of Lossless DLS being disabled after several downgrade and upgrade scenarios. A DC SAN Backbone director logical switch with port based routing, IOD (In-Order Delivery), DLS, and LosslessDLS enabled running Fabric OS 6.3.0b was updated to 6.4.0, and Lossless DLS gets disabled. Fixed in Fabric OS 6.4.0a Workaround prior to upgrade: Re-enable Lossless / IOD on logical switches that were previously enabled. With FMS enabled, after moving all ICL and 254 FC ports into a logical Fixed in Fabric OS 6.4.0a switch with zero based addressing, port 1/0 (area 00) is incorrectly disabled. Data encryption, name server fails to show the existence of a specific virtual initiator. As a result of an external FC port experiencing an excessive number of encoding CRC errors the internal ports are faulted incorrectly by switch firmware, hence a data encryption virtual initiator associated with the internal port fails to appear in name server. Fixed in Fabric OS 6.4.0a Workaround prior to upgrade: Remove the condition / cause of the excessive CRC errors (that is, replace cable or SFP). Unexpected reboot and failover when attempting to push zone DB from DCFM in IM2/IM3 fabrics. Fixed in Fabric OS 6.4.0a Workaround prior to upgrade: Use CLI (or ECFM for non-TI/Redirect zones) in IM2/IM3. In FICON environment, NSD panic while running IRNDUP to 4/256 SAN director due to missing interrupt (IFCC). Fixed in Fabric OS 6.4.0a HP StorageWorks Fabric OS 6.4.0c Release Notes 67