HP 4400 HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 65
Invalid CAL response for CAL class Brocade_SwitchFCPortStats while, On certain target devices
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Closed defect summary Solution bottleneck state may be incorrectly reported on a port after switch dis- Fixed in Fabric OS 6.4.0 able/enable with no traffic running. 4Gb SFPs do not consistently show data in sfpshow on 1606 extension Fixed in Fabric OS 6.4.0 SAN switch GbE ports. License Consumed Slots is zero after config download for some of the Fixed in Fabric OS 6.4.0 slot based licenses. Zone changes of Fabric Class areas in fwconfigure does not work. Fixed in Fabric OS 6.4.0 configdownload of 6.2.0 config file with max tested CTCs (728) failed on 6.3.0 EG. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Do not download configuration with more than 700 containers. Unable to load IF.mib and SW.mib in AdventNet MIB Browser, resulting Fixed in Fabric OS 6.4.0 in the user being unable to load IF.mib and SW.mib. Invalid CAL response for CAL class Brocade_SwitchFCPortStats while EnumerateSelectedInstances operation for virtual port if the virtual port has invalid CAL property, haserror propert y sets to 1. So SMIAgent will not return the instances for the entire logical context. Fixed in Fabric OS 6.4.0 Unable to delete ACL for a port channel in CLI. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Assign the ACL to an empty port-channel Then remove the ACL from the port-channel Then delete the ACL. Trunking tab does not display the ICL's trunk Link where as CLI trunkshow Fixed in Fabric OS 6.4.0 shows even if license is not installed. On certain target devices, Portshow displays "None" on PWWN field while nsshow and switch displays PWWN on the port. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use nsshow or switch to get PWWN of the device. Encryption SAN switch - Blade processor fault when Out of Resource condition occurs and disables the ASIC. Fixed in Fabric OS 6.4.0 Transient detected error on internal link causes blade to be faulted with reason=5 or 4 on 8Gb port blades. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use slotpoweroff and slotpoweron to clear the fault. Inconsistency in encryption HACluster status, following an HA failover on a DC04 SAN director. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use portenable (ISL) or switchenable to fix the fabric. HP StorageWorks Fabric OS 6.4.0c Release Notes 65