HP 8/40 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
HP 8/40 Manual
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP 8/40 manual content summary:
- HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 1
53-1001767-01 ® 30 March 2010 Fabric OS Message Reference Supporting Fabric OS v6.4.0 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 2
or service offered or to be offered by Brocade. Brocade license from the United States government. The authors and Brocade brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 3
and hardware support March 2004 Fabric OS System Error Message 53-0000515-09 Updated for v4.4.0, Reference Manual First RASLog 2005 Reference Manual 1001 Fabric OS System Error Message 53-1000046-01 Added BM, FCR, IPS, FCIP, SEC, and ZONE January 2006 Reference Manual messages Fabric - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 4
FCR, FICON, FICU, FLOD, FSPF, FSSM, FW, HAM, ,HAMK, HIL, IPS, ISNS, L2SYS, MFIC, PDM, PLAT, PORT, RCS, RPCD, RTWR, SEC, SNMP, SWCH, TRCE, TRCK, WEBD, ZONE. FSPF, FSS, FW, HAM, HSL, KAC, KSWD, LANCE, LFM, MS, NS, NSM, PMGR, PORT, PSWP, RKD, SEC, SPC, SPM, SS, SULB, SWCH, TAPE, UCST, UPTH, XTUN, ZONE - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 5
In this chapter lxix How this document is organized lxix Supported hardware and software lxix What's new in this document Logging 1 Event Auditing 2 System Logging Daemon (syslogd 3 System Console 3 Port Logs 3 Viewing and Configuring System Message Logs 4 Viewing System Messages from Web - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 6
Responding to a System Message 11 Looking Up a System Message 12 Gathering Information About the Problem 12 Support 13 Panic Dump and Core Dump Files 13 Trace Dumps 13 supportSave Command 13 System Module Descriptions 13 Section I RASLog Messages Chapter 2 AG System Messages AG-1001 25 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 7
-1004 38 AN-1005 38 AN-1010 38 AUTH System Messages AUTH-1001 39 AUTH-1002 39 AUTH-1003 39 AUTH-1004 40 AUTH-1005 40 AUTH-1006 40 AUTH-1007 40 AUTH-1008 41 AUTH-1010 41 AUTH-1011 41 AUTH-1012 42 AUTH-1013 42 AUTH-1014 42 Fabric OS Message Reference - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 8
Chapter 5 AUTH-1016 42 AUTH-1017 43 AUTH-1018 43 AUTH-1020 43 AUTH-1022 44 AUTH-1023 44 AUTH-1025 45 AUTH-1026 45 AUTH-1027 45 AUTH-1028 46 AUTH-1029 46 AUTH-1030 46 AUTH-1031 47 AUTH-1032 47 AUTH-1033 47 AUTH-1034 48 AUTH-1035 48 AUTH-1036 48 AUTH-1037 49 AUTH-1038 49 AUTH-1039 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 9
Chapter 6 Chapter 7 ANV-1007 54 BKSW System Messages BKSW-1003 57 BL System Messages BL-1000 59 BL-1001 59 BL-1002 59 BL-1003 60 BL-1004 60 BL-1006 60 BL-1007 61 BL-1008 61 BL-1009 61 BL-1010 62 BL-1011 62 BL-1012 62 BL-1013 63 BL-1014 63 BL-1015 64 BL-1016 64 BL-1017 65 BL-1018 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 10
BL-1032 69 BL-1033 69 BL-1034 70 BL-1035 70 BL-1036 70 BL-1037 71 BL-1038 71 BL-1039 71 BL-1041 71 BL-1045 72 BL-1046 72 Chapter 8 BLL System Messages BLL-1000 73 Chapter 9 BLS System Messages BLS-1000 75 BLS-1001 75 BLS-1002 75 BLS-1003 75 BLS-1004 76 BLS-1005 76 Chapter 10 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 11
BM-1058 81 Chapter 11 C2 System Messages C2-1001 83 C2-1002 83 C2-1004 83 C2-1006 84 C2-1007 84 C2-1008 84 C2-1009 85 C2-1010 85 C2-1011 85 Chapter 12 CDR System Messages CDR-1001 87 CDR-1002 87 CDR-1003 87 CDR-1004 88 CDR-1005 88 CDR-1006 88 Chapter 13 CEE CONFIG System - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 12
Chapter 15 CHASSIS System Messages CHASSIS-1002 95 CHASSIS-1003 95 CHASSIS-1004 95 CHASSIS-1005 96 Chapter 16 CNM System Messages CNM-1001 97 CNM-1002 97 CNM-1003 97 CNM-1004 97 CNM-1005 98 CNM-1006 98 CNM-1007 98 CNM-1008 98 CNM-1009 99 CNM-1010 99 CNM-1011 99 CNM-1012 99 CNM- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 13
Fabric OS Message Reference 53-1001767-01 CNM-1031 104 CNM-1032 104 CNM-1033 105 CNM-1034 105 CNM-1035 105 CNM-1036 105 CNM-1037 106 CNM-1038 106 CNM-1039 106 CNM-1040 106 CNM-1041 107 CNM-1042 107 CNM-1043 107 CNM-1044 107 CNM-1045 108 CNM-1046 108 CNM-1047 108 CNM-1048 108 CNM- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 14
CNM-3006 113 CNM-3007 114 CNM-3008 114 CNM-3009 114 CNM-3010 114 CNM-3011 115 CNM-3012 115 Chapter 17 CONF System Messages CONF-1000 117 CONF-1001 117 CONF-1020 117 CONF-1021 118 CONF-1022 118 CONF-1023 118 CONF-1024 118 CONF-1030 119 CONF-1031 119 CONF-1032 119 CONF-1040 119 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 15
CVLC-1011 126 CVLC-1012 126 CVLC-1013 126 CVLC-1014 126 CVLC-1015 127 CVLC-1016 127 CVLC-1017 127 CVLC-1018 127 CVLC-1019 128 CVLC-1020 128 CVLC-1021 128 CVLC-1022 129 CVLC-1023 129 CVLC-1024 129 CVLC-1025 129 CVLC-1026 130 CVLC-1027 130 CVLC-1028 130 CVLC-1029 130 CVLC-1030 131 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 16
CVLM-1011 135 CVLM-1012 135 CVLM-3001 136 CVLM-3002 136 CVLM-3003 136 CVLM-3004 136 CVLM-3005 137 CVLM-3006 137 CVLM-3007 137 CVLM-3008 137 CVLM-3009 138 CVLM-3010 138 CVLM-3011 138 CVLM-3012 138 CVLM-3013 139 CVLM-3014 139 CVLM-3015 139 CVLM-3016 140 CVLM-3017 140 CVLM-3018 140 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 17
DOT1-1006 146 DOT1-1007 146 DOT1-1008 146 DOT1-1009 147 DOT1-1010 147 Chapter 22 EM System Messages EM-1001 149 EM-1002 149 EM-1003 149 EM-1004 150 EM-1005 150 EM-1006 151 EM-1007 151 EM-1008 151 EM-1009 152 EM-1010 152 EM-1011 152 EM-1012 152 EM-1013 153 EM-1014 153 EM-1015 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 18
166 EM-2003 166 Chapter 23 ESS System Messages ESS-1001 167 ESS-1002 167 ESS-1003 167 ESS-1004 168 ESS-1005 168 Chapter 24 ESWCH System Messages ESW-1001 169 ESW-1002 169 ESW-1003 169 ESW-1004 170 ESW-1005 170 xviii Fabric OS Message Reference 53-1001767 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 19
ESW-1006 170 ESW-1007 170 ESW-1008 171 Chapter 25 EVMD System Messages EVMD-1001 173 Chapter 26 FABR System Messages FABR-1001 175 FABR-1002 175 FABR-1003 175 FABR-1004 176 FABR-1005 176 FABR-1006 176 FABR-1007 177 FABR-1008 177 FABR-1009 177 FABR-1010 178 FABR-1011 178 FABR-1012 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 20
FABR-1035 184 FABR-1036 184 FABR-1037 184 FABR-1038 185 FABR-1039 185 FABR-1040 185 FABR-1041 186 FABR-1043 186 FABR-1044 186 FABR-1045 186 FABR-1046 187 FABR-1047 187 FABR-1048 187 FABR-1049 188 Chapter 27 FABS System Messages FABS-1001 189 FABS-1002 189 FABS-1004 189 FABS-1005 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 21
Chapter 30 FCIP System Messages FCIP-1000 199 FCIP-1001 199 FCIP-1002 199 FCIP-1003 199 FCIP-1004 200 Chapter 31 FCOE System Messages FCOE-1001 201 FCOE-1002 201 FCOE-1003 201 FCOE-1004 201 FCOE-1005 202 FCOE-1006 202 FCOE-1007 202 FCOE-1008 202 FCOE-1009 203 FCOE-1010 203 FCOE- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 22
FCOE-1031 208 FCOE-1032 208 FCOE-1033 208 FCOE-1034 209 FCOE-1035 209 FCOE-1036 209 Chapter 32 FCPD System Messages FCPD-1001 211 FCPD-1002 211 FCPD-1003 211 Chapter 33 FCPH System Messages FCPH-1001 213 FCPH-1002 213 Chapter 34 FCR System Messages FCR-1001 215 FCR-1002 215 FCR- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 23
Fabric OS Message Reference 53-1001767-01 FCR-1024 221 FCR-1025 221 FCR-1026 221 FCR-1027 221 FCR-1028 222 FCR-1029 222 FCR-1030 223 FCR-1031 223 FCR-1032 223 FCR-1033 223 FCR-1034 224 FCR-1035 224 FCR-1036 224 FCR-1037 224 FCR-1038 225 FCR-1039 225 FCR-1040 225 FCR-1041 225 FCR- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 24
FCR-1068 231 FCR-1069 231 FCR-1070 232 FCR-1071 232 FCR-1072 232 FCR-1073 233 FCR-1074 233 FCR-1075 233 FCR-1076 234 FCR-1077 234 FCR-1078 234 FCR-1079 234 FCR-1080 235 FCR-1081 235 FCR-1082 235 FCR-1083 236 FCR-1084 236 FCR-1085 236 FCR-1086 236 FCR-1087 237 FCR-1088 237 FCR- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 25
Fabric OS Message Reference 53-1001767-01 FICN-1014 243 FICN-1015 243 FICN-1016 243 FICN-1017 243 FICN-1018 244 FICN-1019 244 FICN-1020 244 FICN-1021 245 FICN-1022 245 FICN-1023 245 FICN-1024 246 FICN-1025 246 FICN-1026 246 FICN-1027 246 FICN-1028 247 FICN-1029 247 FICN-1030 247 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 26
FICN-1051 253 FICN-1052 254 FICN-1053 254 FICN-1054 254 FICN-1055 254 FICN-1056 255 FICN-1057 255 FICN-1058 255 FICN-1059 256 FICN-1060 256 FICN-1061 256 FICN-1062 256 FICN-1063 257 FICN-1064 257 FICN-1065 257 FICN-1066 258 FICN-1067 258 FICN-1068 258 FICN-1069 258 FICN-1070 259 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 27
Chapter 36 FICU System Messages FICU-1001 265 FICU-1002 265 FICU-1003 265 FICU-1004 266 FICU-1005 266 FICU-1006 266 FICU-1007 267 FICU-1008 267 FICU-1009 267 FICU-1010 268 FICU-1011 268 FICU-1012 268 FICU-1013 268 FICU-1014 269 FICU-1015 269 FICU-1016 269 FICU-1017 269 FICU-1018 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 28
FSPF-1005 278 FSPF-1006 278 FSPF-1007 278 FSPF-1008 278 Chapter 40 FSS System Messages FSS-1001 281 FSS-1002 281 FSS-1003 281 FSS-1004 282 FSS-1005 282 FSS-1006 282 FSS-1007 282 FSS- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 29
Fabric OS Message Reference 53-1001767-01 FW-1039 291 FW-1040 291 FW-1041 291 FW-1042 292 FW-1043 292 FW-1044 292 FW-1045 293 FW-1046 293 FW-1047 293 FW-1048 294 FW-1049 294 FW-1050 294 FW-1051 294 FW-1052 295 FW-1113 295 FW-1114 295 FW-1115 296 FW-1116 296 FW-1117 296 FW-1118 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 30
FW-1136 303 FW-1137 303 FW-1138 303 FW-1139 303 FW-1140 304 FW-1160 304 FW-1161 304 FW-1162 305 FW-1163 305 FW-1164 306 FW-1165 306 FW-1166 306 FW-1167 307 FW-1168 307 FW-1169 307 FW-1170 307 FW-1171 308 FW-1172 308 FW-1173 308 FW-1174 309 FW-1175 309 FW-1176 309 FW-1177 310 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 31
Fabric OS Message Reference 53-1001767-01 FW-1192 314 FW-1193 314 FW-1194 315 FW-1195 315 FW-1196 315 FW-1197 316 FW-1198 316 FW-1199 316 FW-1200 316 FW-1201 317 FW-1202 317 FW-1203 317 FW-1204 318 FW-1205 318 FW-1206 318 FW-1207 318 FW-1244 319 FW-1245 319 FW-1246 319 FW-1247 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 32
FW-1332 325 FW-1333 326 FW-1335 326 FW-1336 326 FW-1337 327 FW-1338 327 FW-1339 327 FW-1340 328 FW-1341 328 FW-1342 328 FW-1343 329 FW-1349 329 FW-1350 329 FW-1352 330 FW-1353 330 FW-1354 331 FW-1355 331 FW-1356 331 FW-1357 332 FW-1358 332 FW-1359 332 FW-1364 333 FW-1365 333 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 33
Fabric OS Message Reference 53-1001767-01 FW-1400 338 FW-1401 338 FW-1402 339 FW-1403 339 FW-1404 339 FW-1405 339 FW-1406 340 FW-1407 340 FW-1408 340 FW-1424 340 FW-1425 341 FW-1426 341 FW-1427 341 FW-1428 342 FW-1429 342 FW-1430 342 FW-1431 342 FW-1432 343 FW-1433 343 FW-1434 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 34
FW-1512 348 FW-1513 349 FW-1514 349 FW-1515 349 FW-1516 350 FW-1517 350 FW-1518 350 FW-1519 351 FW-1520 351 FW-1521 351 FW-1522 352 FW-1523 352 FW-1524 352 FW-1525 353 FW-1526 353 FW-1527 353 FW-1528 353 FW-1529 354 FW-1530 354 FW-1531 354 FW-1532 355 FW-1533 355 FW-1534 355 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 35
Chapter 43 HAM System Messages HAM-1001 361 HAM-1002 361 HAM-1004 361 HAM-1005 362 HAM-1006 362 HAM-1007 363 HAM-1008 363 HAM-1009 363 HAM-1010 364 HAM-1011 364 HAM-1012 364 HAM-1013 364 HAM-1014 365 Chapter 44 HAMK System Messages HAMK-1001 367 HAMK-1002 367 HAMK-1003 367 HAMK- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 36
HIL-1301 374 HIL-1302 374 HIL-1303 374 HIL-1304 374 HIL-1305 375 HIL-1306 375 HIL-1307 375 HIL-1308 375 HIL-1309 376 HIL-1310 376 HIL-1311 376 HIL-1401 376 HIL-1402 377 HIL-1403 377 HIL-1404 377 HIL-1501 377 HIL-1502 378 HIL-1503 378 HIL-1504 378 HIL-1505 379 HIL-1506 379 HIL- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 37
Chapter 47 HMON System Messages HMON-1001 385 Chapter 48 HSL System Messages HSL-1000 387 HSL-1001 387 HSL-1002 387 HSL-1003 387 HSL-1004 388 HSL-1004 388 HSL-1005 388 HSL-1006 388 HSL-1007 389 Chapter 49 HTTP System Messages HTTP-1001 391 HTTP-1002 391 HTTP-1003 391 Chapter 50 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 38
Chapter 53 IPAD System Messages IPAD-1000 401 IPAD-1001 401 Chapter 54 IPS System Messages IPS-1001 403 IPS-1002 403 IPS-1003 403 IPS-1004 403 IPS-1005 404 IPS-1006 404 Chapter 55 ISCS System Messages ISCS-1000 405 Chapter 56 ISNS System Messages ISNS-1001 407 ISNS-1002 407 ISNS- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 39
Chapter 58 KSWD System Messages KSWD-1001 413 KSWD-1002 413 Chapter 59 KTRC System Messages KTRC-1001 415 KTRC-1002 415 KTRC-1003 415 KTRC-1004 415 KTRC-1005 416 Chapter 60 L2SYS System Messages L2SS-1001 417 L2SS-1002 417 L2SS-1003 417 L2SS-1004 417 L2SS-1005 418 L2SS-1006 418 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 40
LOG-1003 426 Chapter 65 LSDB System Messages LSDB-1001 427 LSDB-1002 427 LSDB-1003 427 LSDB-1004 428 Chapter 66 MFIC System Messages MFIC-1001 429 MFIC-1002 429 MFIC-1003 429 Chapter 67 MPTH System Messages MPTH-1001 431 MPTH-1002 431 MPTH-1003 431 Chapter 68 MQ System Messages MQ - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 41
Chapter 70 MSTP System Messages MSTP-1001 441 MSTP-1002 441 MSTP-1003 441 MSTP-2001 441 MSTP-2002 442 MSTP-2003 442 MSTP-2004 442 MSTP-2005 442 MSTP-2006 443 Chapter 71 NBFS System Messages NBFS-1001 445 NBFS-1002 445 NBFS-1003 446 Chapter 72 NS System Messages NS-1001 447 NS-1002 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 42
NSM-1009 453 NSM-1010 453 NSM-1011 453 NSM-1012 453 NSM-1013 454 NSM-1014 454 NSM-1015 454 NSM-1016 454 NSM-1017 455 NSM-1018 455 NSM-1019 455 NSM-1020 455 NSM-1021 456 NSM-1022 456 Chapter 74 ONM System Messages ONMD-1000 457 ONMD-1001 457 ONMD-1002 457 ONMD-1003 457 ONMD-1004 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 43
-1004 469 PMGR-1005 470 PMGR-1006 470 PMGR-1007 470 PMGR-1008 470 PMGR-1009 471 PMGR-1010 471 PMGR-1011 471 Chapter 79 PORT System Messages PORT-1003 473 PORT-1004 473 PORT-1005 473 PORT-1006 474 PORT-1007 474 PORT-1008 474 Fabric OS Message Reference xliii 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 44
PORT-1009 474 PORT-1010 475 Chapter 80 PS System Messages PS-1000 477 PS-1001 477 PS-1002 477 PS-1003 477 PS-1004 478 PS-1005 478 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 45
RCS-1002 487 RCS-1003 487 RCS-1004 488 RCS-1005 488 RCS-1006 488 RCS-1007 489 RCS-1008 489 Chapter 84 RKD System Messages RKD-1001 491 RKD-1002 491 RKD-1003 491 RKD-1004 492 RKD-1005 492 Chapter 85 RMOND System Messages RMON-1001 493 RMON-1002 493 Chapter 86 RPCD System Messages - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 46
Chapter 90 SEC System Messages SEC-1001 503 SEC-1002 503 SEC-1003 504 SEC-1005 504 SEC-1006 504 SEC-1007 505 SEC-1008 505 SEC-1009 505 SEC-1010 505 SEC-1016 506 SEC-1022 506 SEC-1024 506 SEC-1025 507 SEC-1026 507 SEC-1028 507 SEC-1029 508 SEC-1030 508 SEC-1031 508 SEC-1032 508 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 47
Fabric OS Message Reference 53-1001767-01 SEC-1053 514 SEC-1054 514 SEC-1055 514 SEC-1056 515 SEC-1057 515 SEC-1059 515 SEC-1062 515 SEC-1063 516 SEC-1064 516 SEC-1065 516 SEC-1069 516 SEC-1071 517 SEC-1072 517 SEC-1073 517 SEC-1074 517 SEC-1075 518 SEC-1076 518 SEC-1077 518 SEC- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 48
SEC-1097 524 SEC-1098 524 SEC-1099 525 SEC-1100 525 SEC-1101 525 SEC-1102 525 SEC-1104 526 SEC-1105 526 SEC-1106 526 SEC-1107 527 SEC-1108 527 SEC-1110 527 SEC-1111 527 SEC-1112 528 SEC-1113 528 SEC-1114 528 SEC-1115 529 SEC-1116 529 SEC-1117 529 SEC-1118 529 SEC-1119 530 SEC- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 49
Fabric OS Message Reference 53-1001767-01 SEC-1155 535 SEC-1156 535 SEC-1157 535 SEC-1158 536 SEC-1159 536 SEC-1160 536 SEC-1163 536 SEC-1164 537 SEC-1165 537 SEC-1166 537 SEC-1167 538 SEC-1168 538 SEC-1170 538 SEC-1171 539 SEC-1172 539 SEC-1173 539 SEC-1174 539 SEC-1175 540 SEC- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 50
SEC-1198 545 SEC-1199 546 SEC-1200 546 SEC-1201 546 SEC-1202 547 SEC-1203 547 SEC-1250 547 SEC-1251 547 SEC-1253 548 SEC-1300 548 SEC-1301 548 SEC-1302 549 SEC-1303 549 SEC-1304 549 SEC-1305 549 SEC-1306 550 SEC-1307 550 SEC-1308 550 SEC-1309 551 SEC-1310 551 SEC-1311 551 SEC- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 51
SEC-1328 556 SEC-1329 556 SEC-1330 556 SEC-1331 557 SEC-1332 557 SEC-1333 557 SEC-3005 557 SEC-3035 558 SEC-3036 558 SEC-3037 558 SEC-3038 559 SEC-3039 559 SEC-3050 559 SEC-3051 559 SEC-3061 560 SEC-3062 560 SEC-3063 560 SEC-3064 560 SEC-3065 561 SEC-3066 561 SEC-4001 561 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 52
SNMP-1005 568 SNMP-1006 568 SNMP-1007 568 SNMP-1008 569 Chapter 93 SPC System Messages SPC-1001 571 SPC-1002 571 SPC-1003 571 SPC-2001 572 SPC-2002 572 SPC-2003 572 SPC-2004 572 SPC-2005 573 SPC-2006 573 SPC-2007 573 SPC-2008 573 SPC-2009 574 SPC-2010 574 SPC-2011 574 SPC-2012 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 53
Chapter 94 SPM System Messages SPM-1001 581 SPM-1002 581 SPM-1003 581 SPM-1004 581 SPM-1005 582 SPM-1006 582 SPM-1007 582 SPM-1008 582 SPM-1009 583 SPM-1010 583 SPM-1011 583 SPM-1012 583 SPM-1013 584 SPM-1014 584 SPM-1015 584 SPM-3001 584 SPM-3002 585 SPM-3003 585 SPM-3004 585 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 54
SPM-3022 590 SPM-3023 590 SPM-3024 590 SPM-3025 590 SPM-3026 591 SPM-3027 591 SPM-3028 591 SPM-3029 591 Chapter 95 SS System Messages SS-1000 593 SS-1001 593 SS-1002 593 SS-1003 594 SS-1004 594 SS-1005 594 SS-1006 594 SS-1007 595 SS-1008 595 Chapter 96 SSM System Messages SSMD- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 55
SSMD-1211 601 SSMD-1212 601 SSMD-1213 601 SSMD-1214 602 SSMD-1215 602 SSMD-1216 602 SSMD-1217 603 SSMD-1300 603 SSMD-1301 603 SSMD-1302 603 SSMD-1303 604 SSMD-1304 604 SSMD-1305 604 SSMD-1306 604 SSMD-1307 605 SSMD-1308 605 SSMD-1309 605 SSMD-1310 605 SSMD-1311 606 SSMD-1312 606 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 56
SULB-1020 616 SULB-1021 616 SULB-1022 617 SULB-1023 617 SULB-1024 617 SULB-1025 618 SULB-1026 618 SULB-1030 618 SULB-1031 618 SULB-1032 619 SULB-1033 619 SULB-1034 619 SULB-1035 619 SULB-1036 620 SULB-1037 620 SULB-1038 620 SULB-1039 621 SULB-1040 621 Chapter 98 SWCH System - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 57
SWCH-1019 628 SWCH-1020 628 SWCH-1021 628 Chapter 99 SYSC System Messages SYSC-1001 629 SYSC-1002 629 SYSC-1003 629 SYSC-1004 630 SYSC-1005 630 Chapter 100 SYSM System Messages SYSM-1001 631 SYSM-1002 631 SYSM-1003 631 SYSM-1004 632 SYSM-1005 632 SYSM-1006 632 SYSM-1007 632 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 58
Chapter 103 TRCK System Messages TRCK-1001 639 TRCK-1002 639 TRCK-1003 639 TRCK-1004 639 TRCK-1005 640 TRCK-1006 640 Chapter 104 TS System Messages TS-1001 641 TS-1002 641 TS-1006 642 TS-1007 642 TS-1008 642 Chapter 105 UCST System Messages UCST-1003 643 UCST-1007 643 UCST-1020 643 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 59
XTUN-1001 649 XTUN-1002 649 XTUN-1003 649 XTUN-1004 650 XTUN-1998 650 XTUN-1999 650 XTUN-2000 650 XTUN-2001 651 XTUN-2002 651 XTUN-2003 651 XTUN-2004 651 XTUN-2005 652 Chapter 109 ZEUS System Messages ZEUS-1001 653 Chapter 110 ZOLB System Messages ZOLB-1001 655 Chapter 111 ZONE System - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 60
ZONE-1026 662 ZONE-1027 663 ZONE-1028 663 ZONE-1029 663 ZONE-1030 664 ZONE-1031 664 ZONE-1032 664 ZONE-1033 664 ZONE-1034 665 ZONE-1035 665 ZONE-1036 665 ZONE-1037 666 ZONE-1038 666 ZONE-1039 666 ZONE-1040 666 ZONE-1041 667 ZONE-1042 667 ZONE-1043 667 ZONE-1044 667 ZONE-1045 668 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 61
AG-1034 675 AG-1035 675 AG-1036 675 AG-1037 676 Chapter 113 AUDIT AN System Messages AN-1003 677 AN-1004 677 AN-1005 677 AN-1006 678 AN-1010 678 Chapter 114 AUDIT AUTH System Messages AUTH-1045 679 AUTH-1046 679 AUTH-1047 679 AUTH-3001 680 AUTH-3002 680 AUTH-3003 680 AUTH-3004 680 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 62
CNM-3009 687 CNM-3010 687 CNM-3011 687 CNM-3012 688 Chapter 117 AUDIT CONF System Messages CONF-1000 689 CONF-1001 689 CONF-1020 689 CONF-1022 690 CONF-1042 690 CONF-1043 690 Chapter 118 AUDIT CVLM System Messages CVLM-3001 691 CVLM-3002 691 CVLM-3003 691 CVLM-3004 692 CVLM-3005 692 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 63
HTTP System Messages HTTP-1002 705 HTTP-1003 705 Chapter 123 AUDIT IPAD System Messages IPAD-1002 707 Chapter 124 AUDIT PORT System Messages PORT-1006 709 PORT-1007 709 PORT-1008 709 PORT-1009 709 Chapter 125 AUDIT SEC System Messages SEC-1113 711 SEC-1114 711 SEC-3001 711 SEC-3002 712 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 64
SEC-3004 712 SEC-3005 713 SEC-3006 713 SEC-3007 713 SEC-3008 714 SEC-3009 714 SEC-3010 714 SEC-3011 714 SEC-3012 715 SEC-3013 715 SEC-3014 715 SEC-3015 716 SEC-3016 716 SEC-3017 716 SEC-3018 717 SEC-3019 717 SEC-3020 717 SEC-3021 717 SEC-3022 718 SEC-3023 718 SEC-3024 718 SEC- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 65
SEC-3045 723 SEC-3046 723 SEC-3047 724 SEC-3048 724 SEC-3049 724 SEC-3050 724 SEC-3051 725 SEC-3061 725 SEC-3062 725 SEC-3063 725 SEC-3064 726 SEC-3065 726 SEC-3066 726 SEC-4001 726 Chapter 126 AUDIT SNMP System Messages SNMP-1004 729 SNMP-1005 729 SNMP-1006 729 Chapter 127 AUDIT - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 66
SPM-3017 735 SPM-3018 735 SPM-3019 735 SPM-3020 736 SPM-3021 736 SPM-3022 736 SPM-3023 736 SPM-3024 737 SPM-3025 737 SPM-3026 737 SPM-3027 737 SPM-3028 738 SPM-3029 738 Chapter 128 AUDIT SULB System Messages SULB-1001 739 SULB-1002 739 SULB-1003 739 SULB-1004 740 SULB-1009 740 SULB - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 67
SULB-1040 751 Chapter 129 AUDIT SWCH System Messages SWCH-1012 753 SWCH-1013 753 SWCH-1014 753 Chapter 130 AUDIT UCST System Messages UCST-1021 755 UCST-1022 755 UCST-1023 755 UCST-1024 756 UCST-1025 756 UCST-1026 756 UCST-1027 756 Chapter 131 AUDIT ZONE System Messages ZONE-3001 759 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 68
ZONE-3022 765 ZONE-3023 765 ZONE-3024 765 ZONE-3025 765 lxviii Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 69
procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for 6.4.0, documenting all - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 70
• Brocade 5100 • Brocade 5300 • Brocade 5410 • Brocade 5424 • Brocade 5450 • Brocade 5460 • Brocade 5470 • Brocade 5480 • Brocade 7500 • Brocade 7500E • Brocade 7600 • Brocade 7800 • Brocade 8000 • Brocade 48000 • Brocade Encryption Switch • Brocade DCX Backbone • Brocade DCX-4S Backbone • Brocade - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 71
- "CNM System Messages" - "AUDIT CNM System Messages" - "CONF System Messages" - "AUDIT CONF System Messages" - "CVLC System Messages" - "CVLM System Messages" - "AUDIT CVLM System Messages" - "FABR System Messages" - "FICU System Messages" - "AUDIT FICU System Messages" - "FW System Messages" - " - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 72
narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is often all lowercase. Otherwise, this manual specifically notes those cases in which a command is case sensitive. Command syntax conventions Command syntax in this - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 73
hardware, firmware, software Brocade and Fibre Channel, see the Brocade Glossary. For definitions of SAN Windows, Windows brocade.com and register at no cost for a user ID and password. White papers, online demonstrations, and data sheets are available through the Brocade website at: http://www.brocade - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 74
applicable • Error numbers and messages received • supportSave command output • Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 75
on the bottom of the port side of the switch • Brocade 7600-On the bottom of the chassis • Brocade 48000-Inside the chassis next to the power supply bays • Brocade DCX-On the bottom right on the port side of the chassis • Brocade DCX-4S-On the bottom right on the port side of the chassis, directly - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 76
lxxvi Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 77
13 Overview of System Messages This guide supports Fabric OS v6.4.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized first by event type, reliability, availability, and serviceability log (RASLog) or AUDIT, and then - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 78
command. support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware switch's error logs. Instead, the switch can be configured to stream Audit messages to the switch default. You must enable - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 79
running UNIX, Linux, or any other operating system that supports the standard syslogd functionality. Configuring for syslogd involves configuring the host, enabling syslogd on the Brocade model, and, optionally, setting the facility level. For the Brocade DCX, 24000 and 48000, each CP has a unique - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 80
Guide for information on interpreting results of the portLogDump command. Port log functionality is completely separate from the system message log. Port logs are typically used to troubleshoot Configuring Event Auditing The procedures are valid for the Brocade DCX, 200E, 3016, 3250, 3850, 3900, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 81
the portLogEventShow command. portLogTypeEnable Enables an event to report to the port log. Port log events are described by the portLogEventShow command. setVerbose Sets the verbose level of a particular module within the Fabric OS. supportFtp Sets, clears, or displays support FTP parameters - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 82
System Parameters and Logs (Continued) Command Description supportFfdc Enables and disables FFDC (first failure data commands. This output is used by your switch service provider to diagnose and correct problems with the switch. The output from this command is very long. syslogDIpAdd Adds an IP - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 83
Media 27: Port media incompatible e. Reason: Configured port speed. Type to continue, Q to stop: Clearing the System Message Log To clear the system message log for a particular switch instance: 1. Log in to the switch as admin. 2. Use the errClear command to clear all messages from memory - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 84
switch:admin> auditcfg --show Audit filter is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 3. Enable the audit feature: switch:admin> auditcfg --enable Audit filter is enabled , ESNSVT_DCX, supportSave has uploaded support information to the host with IP address 168.159.16.128 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 85
this message is for a security issue. FFDC indicates that additional first failure data capture information has also been generated for this event. FID is the Fabric ID that can range from 0 to 128. FID 128 means the message was generated by the default switch instance. CHASSIS is the message that - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 86
was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. The message module and number. These values uniquely identify each message in the Fabric OS and reference the cause and actions recommended in this manual. Note that not - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 87
command to name the chassis or the switchName command to rename the logical switch. port. Responding to a System Message This section provides procedures on gathering information on system messages, including: • Looking Up a System Message • Gathering Information About the Problem • Support - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 88
the steps to produce the problem? - What configuration was in place when the problem occurred? 8. Did a failover occur? 9. Was security enabled? 10. Was POST enabled? 11. Are serial port (console) logs available? 12. Which CP was master? (only applicable to the Brocade DCX, 12000, 24000, or 48000 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 89
Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem. This section describes those files and how to access and/or save the information for support personnel. Panic Dump and Core Dump Files The Fabric OS creates panic dump files and core files - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 90
platforms. Fibre Channel over IP port configuration message over Spike and Striker Blade. Blade management error messages are a result of autoleveling firmware upgrades performed by the control processor (CP). Condor2 error messages indicate problems with the Condor2 ASIC driver module of the Fabric - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 91
lists to all switches in the fabric. Fabric OS system driver module. Firmware blade compatibility errors with control processor (CP). Fibre Channel over IP port configuration messages over Sprint and Marathon Blade. Fibre Channel miscellaneous messages relate to problems with the physical layer - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 92
the switch nondisruptively during failures and software upgrades. These facilities include version negotiation, state information transfer, and internal synchronization functions, enabling the transition from standby to active operation. FSS is defined both as a component and a service. A component - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 93
daemon (diagd) • Environment Monitor (emd) • EVM daemon (evmd) • Exchange Service Support daemon (essd) • FA-API rpc daemon (rpcd) • Fabric daemon (fabricd) error messages indicate problems with the logical fabric manager module that is responsible for making a logical switch use XISLs. This - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 94
read messages from a message queue. The Management Service enables the user to obtain information about the Fibre problems. A group of messages relating to logical switch creation, deletion and configuration. PORT error messages refer to the front-end user ports on the switch. Front-end user ports - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 95
messages indicate problems with the System Services Module of the Fabric OS. The software upgrade library provides the firmwareDownload command capability, which enables firmware upgrades to both CP blades with a single command, as well as nondisruptive code load to all 4.x switches. These messages - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 96
log. Additionally, if the SNMP trap option is enabled, an SNMP trap is also sent. For information on configuring the track change feature, refer to the Fabric OS Command Reference or the Fabric OS Administrator's Guide. Time Service provides fabric time-synchronization by synchronizing all clocks in - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 97
RASLog Messages Section I This section provides the RASLog messages, including: •AG System Messages 25 •AN System Messages 37 •AUTH System Messages 39 •ANV System Messages 53 •BKSW System Messages 57 •BL System Messages 59 •BLL System Messages 73 •BLS System Messages 75 •BM System Messages - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 98
387 •HTTP System Messages 391 •IBD System Messages 393 •IBPD System Messages 395 •ICPD System Messages 397 •IPAD System Messages 401 •IPS System Messages 403 •ISCS System Messages 405 •ISNS System Messages 407 •KAC System Messages 411 •KSWD System Messages 413 •KTRC System Messages - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 99
•PDM System Messages 459 •PDTR System Messages 465 •PLAT System Messages 467 •PMGR System Messages 469 •PORT System Messages 473 •PS System Messages 477 •PSWP System Messages 481 •RAS System Messages 483 •RCS System Messages 487 •RMOND System Messages 493 •RKD System - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 100
24 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 101
this command. • Some blades and ports in a switch may not support NPIV. NPIV functionality can not be enabled on such ports and they will not respond to NPIV requests. Refer to the Access Gateway Administrator Guide, Appendix B, for specific AG-compatibility requirements. • On non-Brocade switches - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 102
command and contact your switch service provider. Severity ERROR AG-1005 Message , [AG-1005], ,, WARNING, , FDISC response was dropped because F_Port - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 103
up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1009 Message , [AG-1009], ,, WARNING, , Sending FLOGI failed on N_Port . Probable Cause Indicates there was a failure sending - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 104
set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1013 Message , [AG-1013], ,, INFO, , F_Ports mapped to N_Port failed over to other N_Ports. Probable Cause Indicates the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 105
up automatic FTP transfers; then run the supportsave command and contact your switch service provider. Severity WARNING AG-1016 Message , [AG-1016], ,, INFO, , Failing over F_Ports mapped to N_Port to other N_Ports. Probable Cause Indicates the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 106
the ag --mapshow command to display the updated F_Port-to-N_Port mapping. Action Severity INFO AG-1021 Message , [AG-1021], ,, WARNING, , Unable to do Preferred-Failover of F_Port . Failover across different fabric is not supported. Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 107
to the attached F_Ports on the edge switch is the same. Recommended Action Run the porttrunkarea --show command on the attached switch to display that the Trunk Area is assigned to all ports in the system and run the porttrunkarea --enable command to reconfigure the Trunk Area. Severity ERROR - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 108
then run the supportSave command and contact your switch service provider. Severity WARNING AG-1027 Message , [AG-1027], ,, WARNING, , Unable to handle this login request on port because NPIV capability is not enabled on this port. Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 109
action is required. Action Severity WARNING AG-1031 Message , [AG-1031], ,, WARNING, , Loop Detected for device with Port WWN connected to port Probable Cause Indicates that the routing Loop is detected for the device connected to the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 110
], ,, WARNING, ,Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Probable Cause Indicates that one of the ports is connected to a non-Brocade fabric. Recommended No action is required - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 111
AG-1038 2 Recommended Action If the switchshow command on the connected fabric switch port displays 'Persistently disabled: Area has been acquired', then check the cabling on the AG. All trunked ports in a single trunk should belong to the same ASIC Port Group. Severity INFO AG-1038 Message < - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 112
2 AG-1039 36 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 113
switch using the memShow command. Restart or power cycle the Action switch firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command to frames going out of this port. This latency may be inherent in the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 114
WARNING, , Severe latency bottleneck detected at Slot port . Probable Cause Indicates a credit loss. Recommended Contact your vendor's customer support for assistance. Action Severity WARNING 38 Fabric OS Message Reference 53-1001767 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 115
type can be "set" or "remove". Recommended Action Retry the secAuthSecret command. Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1003 Message , [AUTH-1003 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 116
; then run the supportSave command and contact your switch service provider. Severity WARNING AUTH-1007 Message Probable Cause , [AUTH-1007], ,, ERROR, , The proposed authentication protocols are not supported: port . Indicates that the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 117
Indicates an internal problem with the Secure Fabric OS. Recommended Action Reboot or power cycle the switch. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 118
run the supportSave command and contact your switch service provider. Severity WARNING AUTH-1014 Message , [AUTH-1014], , FFDC, ERROR, , Invalid port value to : port . Probable Cause Indicates an internal problem with the Secure - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 119
then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1018 Message , [AUTH-1018], ,, ERROR, , Invalid value to check protocol type: port . Probable Cause Indicates an internal problem with the Secure - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 120
transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1023 Message , [AUTH-1023], ,, ERROR, , Failed to during : port . Probable Cause Indicates an - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 121
transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1026 Message , [AUTH-1026], ,, WARNING, , Failed to get during negotiation phase: port . Probable Cause Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 122
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1028 Message , [AUTH-1028], ,, ERROR, , Failed to allocate for : port . Probable Cause Indicates that - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 123
transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1033 Message Probable Cause , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch . Indicates that an - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 124
transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1036 Message , [AUTH-1036], ,, ERROR, , Invalid state for : port . Probable Cause Indicates that - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 125
the authentication negotiation, and the local switch has a strict switch authentication policy. Recommended Correct the switch policy configuration on either of the switches using the authUtil command, and Action then enable the port using the portEnable command. Fabric OS Message Reference 49 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 126
authentication. Recommended Action If there is no light on the port, correct the switch policy configuration on either of the switches using the authUtil command, and then enable the port on the neighboring switch using the portEnable command. If the E_Port formed, no action is required. Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 127
will be defaulted to OFF, and switch will not participate enable the port using the portEnable command. Action Severity ERROR AUTH-1045 Message , [AUTH-1045], ,, ERROR, , Certificate not present in this switch in port - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 128
Operation type can be "set" or "remove". Recommended Action Retry the secAuthCertificate command. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR 52 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 129
All the ports on the blade or switch will be disrupted. Recommended Action For a bladed system, execute the slotPowerOff and slotPowerOn commands on the Recommended Restart the system at the next maintenance window. If the problem persists, replace the blade. Action Severity CRITICAL Fabric - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 130
integrated circuit (ASIC) hardware that renders the chip as not operational. Recommended Restart the system at the next maintenance window. If the problem persists, replace the blade. Action Severity CRITICAL ANV-1007 Message , [ANV-1007], ,, CRITICAL, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 131
Severity CRITICAL ANV-1007 5 Fabric OS Message Reference 55 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 132
5 ANV-1007 56 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 133
daemons is found to be nonresponsive; sending signal abort. Recommended Action Run the supportSave command to determine if any core files were created. If a core file is found, information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 57 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 134
6 BKSW-1003 58 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 135
not have hardware problems. To run this command root access is required. To run this command root access is required. Refer to the Fabric OS Command Reference Manual for more information on this command. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Additional blade - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 136
to verify that blade does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 137
that the blade does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. Fabric OS Message Reference 61 53-1001767 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 138
attached to the specified port. Run the systemVerification command to verify that the blade or switch does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. On a bladed switch, run the slotPowerOff - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 139
cable, small form-factor pluggable (SFP), or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, restart or power cycle the switch. If the message persists, replace the blade. Severity ERROR BL-1014 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 140
error. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade 24000, and 48000, replace - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 141
problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands the slot has completed initializing the ports. Recommended No action is required. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 142
Restart or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 143
as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all GbE or Fibre Channel over IP (FCIP) or Virtualization data elements or FC Fastwrite ports were reset - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 144
an internal port went offline during the warm recovery of the switch. The switch will reboot and start a cold recovery. Recommended Collect supportSave information, then restart the switch and run the diagPost command to ensure Action Power-On Self-Test (POST) is enabled. If the problem persists - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 145
Fastwrite ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GbE or Fibre Channel over IP (FCIP - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 146
messages from the user ports after disabling the ports. Recommended Action Restart or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If the message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 147
miniS number>, port = due to BE/BI port fault. Probable Cause Indicates a fault on the chip and that all ports on the enabled on default switch, Faulting the blade w/ ID in slot as it does not support - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 148
system-name>, mini SFP+ (SN: ) is only supported in certain high port count blades, not blade in slot - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 149
ASIC driver detected Slot port as faulty (reason: ) Probable Cause Indicates a blade regulation problem was reported or power cycle the blade. Run the systemVerification command to verify that the blade does not have any hardware problems. To run this command - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 150
8 BLL-1000 Severity CRITICAL 74 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 151
sequence-number>,, ERROR, , of GE failed. Please retry the command. Data: inst= st= - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 152
end of the tunnel does not support the Tape Read Pipelining feature. Recommended No action is required. Action Severity INFO BLS-1005 Message , [BLS-1005], ,, ERROR, , S,P [OID 0x8x]: - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 153
on the application processor (AP) blade. You can modify the firmware version on the CP blade by using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmware download is supported between the revisions. Because the AP and CP blades cannot communicate - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 154
for the blade in the specified slot. Recommended Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade Action 7500 or 7600, switch off and switch on all primary power to power-cycle the unit. Severity WARNING BM-1006 Message , [BM-1006], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 155
due to a firmware upgrade. Recommended Issue the firmwareDownload command to recover the blade. Action Severity WARNING BM-1009 Message , [BM-1009], ,, WARNING, , Firmwaredownload timed-out for application processor. Faulting switch. Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 156
to communicate. Recommended On the Brocade 7500 or 7600, switch off and switch on all the primary power to power-cycle the Action unit. Severity WARNING BM-1054 Message , [BM-1054], ,, INFO, , AP firmware is not consistent with system - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 157
the switch to persistently enable all ports. Action Severity INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue firmwaredownload to recover. Probable Cause Indicates the automatic firmware upgrade on - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 158
10 BM-1058 82 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 159
system-name>, Port chip faulted due to an internal error. Probable Cause Internal error. All the ports on the blade or switch will be disrupted is observed, restart the system at the next maintenance window. If the problem Action persists, replace the blade. Severity ERROR Fabric OS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 160
Message Message , [C2-1007], ,, WARNING, , S , P (): best effort QOS will be turned off at next port state change as it is not supported under this configuration. Probable Cause Indicates QoS will be turned off - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 161
>: Primitive received with Encoding errors, do AL_RESET. Probable Cause Indicates encoding errors on the internal links. Recommended This error can cause CRC errors or frame loss. If the error is observed continuously, power cycle the Action affected blade first. If the problem - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 162
11 C2-1011 86 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 163
chip faulted due to internal error. Probable Cause Indicates an internal error. Recommended Action For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover the system. For a non-bladed system, perform fastBoot command on the switch to recover - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 164
Whenever this error occurs, restart the system at the next maintenance window. If the problem Action persists, replace the blade. Severity ERROR CDR-1005 Message the next port state change because best effort is no longer supported on a 4G platform or 8G platform long distance port. Recommended No - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 165
(CEE) configuration management daemon has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CCFG-1002 Message , [CCFG-1002], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 166
startup configuration has been moved or deleted, hence replaying the system configuration has failed. Recommended Use the copy file startup-config command to restore the startup configuration from any backup Action retrieved on the server. Severity ERROR CCFG-1005 Message , [CCFG-1005 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 167
that the inserted linecard is different from the pre-configured one. Recommended Remove the incompatible linecard or use no linecard command to remove configuration. Action Severity WARNING CCFG-1012 Message , [CCFG-1012], ,, ERROR, , Blade in slot - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 168
mentioned slot has failed to reach the Online state within the specified time after system ready event. Recommended Run the slotpoweroff command followed by the slotpoweron command on the slot to retry bringing Action the slot online. Severity ERROR 92 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 169
loaded on the standby CP. The standby CP does not support the Advanced Performance Tuning module when the fibre connectivity (FICON) Management Server is enabled. Recommended Action Run the firmwareDownload command to upgrade the firmware on the standby CP. You can also disable FMS on the active - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 170
14 CER-1001 94 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 171
as inconsistent during failover or recovery. Recommended On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn Action command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR CHASSIS-1004 Message , [CHASSIS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 172
24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, or AP7600 switch, reboot or power cycle the switch. Severity ERROR 96 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 173
group using the cryptodevicecfg command. Refer to the Action Fabric OS Command Reference Manual for more information on this command. Severity WARNING CNM-1004 Message , [CNM-1004], ,, INFO, , iSCSI service is on the switch. Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 174
16 CNM-1005 Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, , Posting event CNM_EVT_GRP_LEADER_ELECTED Name [ - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 175
16 CNM-1009 Recommended No action is required. Action Severity INFO CNM-1009 Message , [CNM-1009], ,, INFO, , Posting event CNM_EVT_STANDALONE_MODE. Probable Cause Indicates that the node is in standalone mode. Recommended No action is required. Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 176
16 CNM-1013 Recommended No action is required. Action Severity INFO CNM-1013 Message , [CNM-1013], ,, INFO, ,Posting event GL Node Split condition, isolating peer GL node . Probable Cause Indicates that the encryption group (EG) is split. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 177
16 CNM-1017 Recommended No action is required. Action Severity INFO CNM-1017 Message , [CNM-1017], ,, INFO, ,Got JOIN REQUEST from un-recognized GL node [], configured GL node is []. Probable Cause Indicates a join request was received - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 178
16 CNM-1021 Probable Cause Indicates that the Node Admission Control has failed. Recommended No action is required. Action Severity INFO CNM-1021 Message , [CNM-1021], ,, INFO, , Failed to sign the node authentication message, admission control might - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 179
Hdr version Expected Hdr version Node . Probable Cause Indicates that a version mismatch has occurred. Recommended Upgrade the firmware or delete the Node from the encryption group (EG). Action Severity INFO CNM-1027 Message , [CNM-1027], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 180
16 CNM-1029 Probable Cause Indicates that the certificate file for the node already exists. Recommended No action is required. Action Severity INFO CNM-1029 Message , [CNM-1029], ,, WARNING, , Certfile content does not match the cert sent by GL. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 181
16 CNM-1033 Probable Cause Indicates that there is a size mismatch between a node's certificate file and the certificate file received from the group leader. Recommended No action is required. Action Severity WARNING CNM-1033 Message , [CNM-1033], ,, WARNING, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 182
16 CNM-1037 Probable Cause Indicates an event is being posted to indicate that the cluster is in a converged state. Recommended No action is required. Action Severity INFO CNM-1037 Message , [CNM-1037], ,, INFO, , Split-Brain Arbitration lost!, minority - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 183
, Updating persistent Cluster DB, please avoid powering off the switch. Probable Cause Indicates the system is updating the persistent ERROR, , Received HBT from undefined node IpAddress [], WWN []. Possible configuration error. Probable Cause Indicates that the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 184
is required. Action Severity INFO CNM-1047 Message , [CNM-1047], ,, INFO, , Network Interface to Remote Node is . Probable Cause Indicates that the status of the network interface is UP or DOWN. Recommended No action is required. Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 185
Gateway Daemon mode mismatch, ensure mode settings are same across all nodes in EG. Probable Cause Indicates mode mismatch between the switches like the Access Gateway mode mismatch. Recommended No action is required. Action Severity ERROR CNM-1052 Message Probable Cause , [CNM - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 186
-1056 Message Probable Cause , [CNM-1056], ,, INFO, , Posting event CNM_EVT_EE_INITIALIZING Slot , Wwn , IP , flags . Indicates that the encryption engine (EE) is added into the encryption group (EG). 110 Fabric OS Message Reference - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 187
Severity INFO CNM-1057 Message , [CNM-1057], ,, INFO, , Posting event CNM_EVT_ONLINE Slot , Wwn , IP , flags . Probable Cause Indicates that the encryption engine (EE) is online in the encryption group (EG). Recommended No action is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 188
. Action Severity INFO CNM-1061 Message , [CNM-1061], ,, INFO, , IP of the switch changed from [] to []. Probable Cause Indicates that the switch IP has changed. Recommended No action is required. Action Severity INFO CNM-1062 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 189
16 CNM-3003 Recommended No action is required. Action Severity INFO CNM-3003 Message , [CNM-3003],,, INFO, , Event: cryptocfg Status: success, Info: Membernode \\ added to encryption group. Probable Cause Indicates a member node was added - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 190
16 CNM-3007 Recommended No action is required. Action Severity INFO CNM-3007 Message , [CNM-3007],,, INFO, , Event: cryptocfg Status: success, Info: Heartbeat timeout set to . Probable Cause Indicates that the heartbeat timeout value was set. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 191
16 CNM-3011 Recommended No action is required. Action Severity INFO CNM-3011 Message , [CNM-3011], ,, INFO, , Event: cryptocfg Status: success, Info: Encryption group synchronized. Probable Cause Indicates an encryption group was synchronized. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 192
16 CNM-3012 116 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 193
classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description. Recommended No action is required , correct the error and rerun the configdownload command. Action Severity INFO Fabric OS Message Reference 117 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 194
was unsuccessful because there are one or more parameters that require the switch to be disabled. Recommended Disable the switch using the switchDisable command and download the configuration. Action Severity WARNING CONF-1023 Message , [CONF-1023], ,, INFO, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 195
Configuration database full, data not committed (key:. Probable Cause Indicates that the previous configuration commands have resulted in a database full condition. Configuration changes associated with the specified key have not been applied. Recommended Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 196
17 CONF-1041 CONF-1041 Message , [CONF-1041], ,, INFO, , configRemove failed. Probable Cause Indicates a configRemove error has occurred. Recommended Correct the error and try again. Action Severity INFO CONF-1042 Message , [CONF-1042], < - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 197
Chapter CTAP System Messages 18 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for . Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 198
18 CTAP-1001 122 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 199
, Initiator: , LUN ID: . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed. The operation has been started, completed or cancelled. Recommended No action is required. Action Severity INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 200
, [CVLC-1007], ,, ERROR, , Removal of encryption LUN is not allowed when decrypt of existing data is enabled.\nContainer: , Initiator: , LUN ID: . Indicates that there has been an attempt to remove the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 201
is required for tape container: . Probable Cause Indicates that the tape container is configured with non-Brocade mode but there is no valid license. Recommended Obtain license for non-Brocade mode. Action Severity ERROR Fabric OS Message Reference 125 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 202
encryption LUN is configured with non-Brocade mode but there is no valid license. Recommended Obtain license for non-Brocade mode. Action Severity ERROR CVLC Indicates that the encryption engine is unable to retrieve the key record base on the key ID found in the metadata. Recommended No action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 203
19 CVLC-1015 Recommended Use cryptocfg command to add the key ID, if available. Action Severity ERROR CVLC-1015 Message , [CVLC-1015], ,, ERROR, , LUN is set to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 204
that the data state in the LUN configuration is in clear text state but metadata exists on the LUN. Recommended Use cryptocfg command to confirm the configuration. Action Severity ERROR CVLC-1020 Message , [CVLC-1020], ,, ERROR, , Metadata exists while - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 205
ID: . Probable Cause Indicates that the secondary metadata exists on the LUN that is not configured with --newLUN option. Recommended Use th ecryptocfg command to remove and add the LUN with --newLUN option. Action Fabric OS Message Reference 129 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 206
, Initiator: , LUN ID: . Probable Cause Indicates a warning event. Recommended Perform a manual rekey on this LUN. Action Severity WARNING CVLC-1029 Message Probable Cause , [CVLC-1029], ,, WARNING, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 207
. Probable Cause Indicates the manual rekey was completed on primary LUN. Recommended Action 1. Make the target ports of the mirror LUN offline to hosts Add it to its container with -newLUN option. 3. Using host based migration application, copy data from old to new primary LUN. Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 208
, LUN ID: because . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation failed. Recommended No action is required. Action Severity INFO CVLC-1035 Message , [CVLC-1035], ,, ERROR - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 209
Check the memory usage on the switch using the memShow command. Restart or power cycle the Action switch. Severity ERROR CVLM-1002 Message < new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 210
the Fabric OS Command Reference Manual for more information on this command. Severity WARNING CVLM-1005 Message , [CVLM-1005], ,, INFO, , Crypto service is on the switch. Probable Cause Indicates that Crypto service is enabled or disabled on - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 211
20 CVLM-1009 Recommended Check the ISL port connected to the fabric. Action Severity WARNING CVLM-1009 Message < CVLM-1010 Message , [CVLM-1010], ,, WARNING, , The IP address of EE IO link is not configured. Probable Cause Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 212
20 CVLM-3001 Recommended No action is required. Action Severity INFO CVLM-3001 Message , [CVLM-3001], ,, INFO, , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates the failback mode was set. Recommended - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 213
20 CVLM-3005 Recommended No action is required. Action Severity INFO CVLM-3005 Message , [CVLM-3005], ,, INFO, , Event: cryptocfg Status: success, Info: Cluster member removed from HA cluster . Probable Cause Indicates an HA cluster member - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 214
[CVLM-3009], ,, INFO, , Event: cryptocfg Status: success, Info: Manual failback from EE / to EE /. Probable Cause Indicates a manual failback was performed to an encryption engine. Recommended No action is required - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 215
20 CVLM-3013 Probable Cause Indicates an initiator was removed from a cryptotarget container. Recommended No action is required. Action Severity INFO CVLM-3013 Message , [CVLM-3013], ,, INFO, , Event: cryptocfg Status: success, Info: LUN , - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 216
, Info: Lun , attached through Initiator \\, in crypto target container \\ enabled. Probable Cause Indicates a LUN in a cryptotarget container was enabled. Recommended No action is required. Action Severity INFO CVLM-3017 Message , [CVLM - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 217
Message , [CVLM-3021], ,, INFO, , Event: cryptocfg Status: success, Info: Manual rekey all performed. Probable Cause Indicates a complete manual rekey was performed. Recommended No action is required. Action Severity INFO CVLM-3022 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 218
, LUN ). Probable Cause Indicates that the decommission operation has failed for the device. Recommended Reissue the decommission command. Action Severity INFO CVLM-3027 Message , [CVLM-3027], ,, INFO, , Event: cryptocfg Status: success - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 219
20 CVLM-3028 CVLM-3028 Message , [CVLM-3028], ,, INFO, , Event: cryptocfg Status: success, Info: SRDF mode set to . Probable Cause Indicates that the SRDF mode was set. Recommended No action is required. Action Severity INFO Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 220
20 CVLM-3028 144 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 221
INFO DOT1-1003 Message , [DOT1-1003], ,, INFO, 802.1X is enabled for port . Probable Cause Indicates that the 802.1X is enabled for a particular port. Recommended No action is required. Action Severity INFO DOT1-1004 Message Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 222
timestamp>, [DOT1-1006], ,, WARNING, 802.1X Authentication has failed on port . Probable Cause Indicates that the authentication has failed on a particular port. Recommended Check the credentials configured with Supplicant and the RADIUS server. Action Severity WARNING - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 223
No action is required. Action Severity INFO DOT1-1010 Message , [DOT1-1010], ,, INFO, Port is set in auto mode. Probable Cause Indicates that the port is set to auto mode. Recommended No action is required. Action Severity INFO Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 224
21 DOT1-1010 148 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 225
of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Run the fanShow command to is faulted. Recommended Action On Brocade 24000 and 48000, try reseating the specified FRU. Restart or power cycle the switch. Fabric OS Message Reference 149 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 226
and an optional number to identify the unit, slot, or port. The Brocade 3250 has one power supply and three fans, and the Brocade 3850 has two power supplies and four fans. Values for the individual fans and power supplies for these switches might display, but these parts cannot be replaced: the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 227
switch for nonbladed switches. Recommended Action There is most likely a voltage hardware problem on the blade or motherboard of the switch. For the Brocade the incompatibility is with the logical switch configuration, change the configuration with the lscfg command to be consistent with the blade - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 228
the FRU. Refer to the Brocade 48000 Hardware Reference Manual for more information about chassisConfig modes and supported blades. Severity CRITICAL EM-1010 ; however, after four seconds it cannot be determined if it has powered down or not. Recommended Try reseating the blade. If this fails to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 229
persists, restart or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. To run this command root access is required. Refer to the Fabric OS Command Reference Manual for more information on this command. If the message persists - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 230
problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service reboot, power cycle firmware version - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 231
not supported by the firmware on with the chassisConfig command, or upgrade the Action firmware on the problem. The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or port. Recommended Action If the message persists, reboot or power cycle the switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 232
, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 233
22 EM-1035 EM-1035 Message , [EM-1035], ,, ERROR, , 2 circuit paired Power Supplies are faulty, please check the AC main switch/circuit to see if it has power. Fabric OS Message Reference 157 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 234
(WWN) card, then default WWN and IP addresses are used for the switch. Recommended Action Reseat the FRU card. If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. To run this command root access is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 235
or off. Recommended The specified FRU is not responding to commands and should be replaced. Action Severity WARNING EM-1044 Message , [EM-1044], ,, WARNING, , Can't power on , its logical switch is shut down Fabric OS Message Reference 159 53 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 236
CP256) is not supported on that chassis (backplane revision D2), remove the blade from the chassis. If the reason is switch configuration, the blade's logical switch configuration is not correct. Run the lscfg command to correct the switch or port configuration for the ports on that blade. Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 237
access to the field-replaceable unit (FRU) has become available again. Recommended The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is Action displayed. Severity INFO EM-1049 Message , [EM-1049], ,, INFO, , FRU - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 238
-1058 Message , [EM-1058], ,, WARNING, , Switch gets reset: Probable Cause Indicates the switch is being automatically reset because of a known resetable transient problem such as an application-specific integrated circuit (ASIC) parity error - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 239
is compatible with your switch type. Action Severity ERROR supported by the release on the standby control processor (CP). Recommended Action Remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken, this CP must be rebooted or the haSyncStart command - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 240
you have selected to power off the problem blade when such a condition occurred. Recommended Contact the switch provider for support. Action Severity CRITICAL EM-1065 Message , [EM-1065], ,, WARNING, , SSAS Virtualization Services are not available due - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 241
Fabric OS or Storage Application Services (SAS) firmware has been upgraded and is now compatible. problems on the switch. Recommended Reboot or power cycle the switch. If the message persists, collect switch information using the Action supportsave command, and contact your switch service - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 242
specified FRU. On nonbladed switches, reboot or power cycle the switch. If the problem persists: • Run the systemverification command to verify that the switch does not have hardware problems. To run this command root access is required. Refer to theFabric OS Reference Manual for more information on - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 243
Action Discontinue the firmware download, identify the downlevel switch or switches that do not support the Coordinated HotCode protocol, and upgrade the downlevel switches. Then, restart the firmware download on this switch. Note that upgrading a downlevel Brocade switch in a mixed interop - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 244
Indicates that during the Coordinated HotCode protocol, a switch in the fabric did not accept the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended No action is required. Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 245
flags>. Probable Cause Indicates that the switch enable has failed. Recommended If the message persists, run the supportFtp command (as needed) to set up automatic FTP Action transfers; then run the supportSave command and contact your switch service provider. Severity ERROR ESW-1002 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 246
On a Brocade 8000 switch, restart or power cycle the switch. Action firmware version on standby that supports NPIV functionality, using the firmwareDOwnload Action command. Severity WARNING ESW-1007 Message , [ESW-1007], ,, WARNING, ,Switch port - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 247
. Probable Cause Indicates that the blade has area swapped ports on ports that do not support this feature. Recommended Replace the blade with ports that support port swap. Refer to the Fabric OS Administrator's Guide Action for more information. Severity WARNING Fabric OS Message Reference - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 248
24 ESW-1008 172 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 249
EVMD System Messages 25 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause Indicates the event could not be sent to remote proxy. This could happen if the remote proxy - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 250
25 EVMD-1001 174 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 251
Cause Indicates that an internal link service (ILS) information unit of invalid size has been received. The neighbor switch has sent a payload with an invalid size. Recommended Action Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch to view the error log - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 252
command and contact your switch service provider. Severity WARNING FABR-1004 Message , [FABR-1004], ,, WARNING, , port: - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 253
problem with the Fabric OS. Recommended Action In case of severe memory corruption, the system might recover by performing an automatic failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 254
message is rare and usually indicates a problem with the Fabric OS. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FABR-1011 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 255
ididmode. A '0' means the IDID mode is disabled; a '1' means it is enabled. Set the switch to insistent domain ID mode. This mode is set under the configure command or in Web Tools on the Switch Admin > Configure window. Severity ERROR FABR-1015 Message , [FABR-1015], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 256
1016 Message , [FABR-1016], ,, WARNING, , ficonMode is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface command. Recommended No action is required. Action Severity WARNING FABR-1017 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 257
limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1022 Message , [FABR-1022], , FFDC, CRITICAL, , Fabric size () exceeds supported configuration (). Fabric limit timer ( - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 258
fabric must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. Severity INFO FABR-1029 Message Probable Cause , [FABR-1029], ,, INFO, , Port negotiated (mode - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 259
the buffer credits are fixed, based on the port configuration information. In this port number> exceeded. Probable Cause Indicates the fabric exhausted the maximum number of retries sending internal link service (ILS) to the iswitchd demon on the specified E_Port. Recommended Run the top command - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 260
You must manually enable the port or the port remains disabled forever. Refer to the Admin Guide for more enabled port. Persistently disabling port . Probable Cause Indicates the specified port is being disabled because when the port on a Switch is Trunk Area enabled - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 261
is enabled without a trunking license being present. Recommended Install a trunking license or disable F_port trunking on the port. Action Severity INFO FABR-1039 Message , [FABR-1039], , WARNING, , Invalid domain id zero received from principal switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 262
port. Recommended Action Enable the port by running the portEnable command. The port may recover by re-initialization of the link. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers followed by the supportSave command and contact your switch service - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 263
fabric have the same Base Switch attribute or upgrade the Action switch firmware to a VF-capable firmware. Severity ERROR FABR-1047 Message , [FABR-1047], , INFO, , Area unavailable to assign to the port. Persistently disabling port - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 264
with the inherited FID of the local switch. All E_ports directly connected to the conflicting switch are disabled. Recommended Make sure that all the switches in the fabric have same Fabric ID or upgrade the switch firmware to Action a VF-capable firmware. Severity ERROR 188 Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 265
by the software. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1004 Message , [FABS-1004], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 266
an invalid value in an object's status field. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. 190 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 267
unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1011 Message Probable Cause , [FABS-1011 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 268
problem. Recommended Action Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware inability to read the FRU header, or the blade may not be supported by this platform or Fabric OS version. Recommended Action Verify that the blade - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 269
specified FRU could not be enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 270
27 FABS-1015 194 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 271
Action The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 272
28 FBC-1001 196 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 273
is low on memory and failed to allocate new memory for an information unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 274
29 FCMC-1001 198 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 275
number>, FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 276
-1004 Message , [FCIP-1004], , INFO, CFG, , Tape Read Pipelining is being disabled slot () port () tunnel (). Probable Cause Indicates that the FOS version on the remote end of the tunnel does - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 277
>. Probable Cause Indicates a memory failure. Recommended Check the switch memory status. Action Severity ERROR FCOE-1002 Message , Recommended Check the login group changes using the fcoelogincfg --show command. Action Severity INFO FCOE-1004 Message Probable Cause , - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 278
31 FCOE-1005 Recommended Remove the failed member from the login group. Action Severity ERROR FCOE-1005 Message , [FCOE-1005], ,, ERROR, , : membership check failed in lg: Probable Cause Indicates that the Membership check for the device has - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 279
Message , [FCOE-1010], ,, ERROR, , Cleanup of login failed for port:. Probable Cause Indicates an invalid port number. Recommended Use the supportsave command and restart the system. Action Severity ERROR FCOE-1011 Message , [FCOE-1011 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 280
for ifindex 0xx failed, rc:. Probable Cause Indicates an add request to L2 for slot or port has failed. Recommended Rerequest to add MACs to L2 for slot/port. Action Severity ERROR FCOE-1016 Message Probable Cause , [FCOE-1016], ,, ERROR, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 281
Configure FC-MAP on FCOE vlan. Action Severity WARNING FCOE-1021 Message Probable Cause , [FCOE-1021], ,, INFO, , Port is already logged in. Indicates a Nport device has already logged in or is in the process, duplicate FLOGI received. Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 282
device limit. Recommended Do not add any more FCoE devices to the switch. Action Severity WARNING FCOE-1023 Message , [FCOE-1023], < ,, WARNING, , FCOE logout received on FIP VN port. Indicates a pre-FIP logout for a device that has logged in using - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 283
. FDISC addressed to different FCF than base FLOGI. Probable Cause Indicates the base port has sent an FLOGI but the subsequent FDISC's that was received on the switch does not match the original FLOGI. Recommended It is due to a CNA/target driver issue. No action is required. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 284
[FCOE-1030], ,, WARNING, , Version mismatch between FIP LOGO and root VN port. Probable Cause Indicates a version mismatch between the FIP logout and base FLOGI. Recommended No action is required. Action Severity WARNING FCOE-1031 Message , [FCOE-1031 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 285
-1035 Message , [FCOE-1035], ,, INFO, , Virtual FCoE port () enabled. Probable Cause Indicates an administrative action on FCoE port. Recommended No action is required. Action Severity INFO FCOE-1036 Message , [FCOE - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 286
31 FCOE-1036 210 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 287
the device vendor for a firmware upgrade containing a defect fix. Severity WARNING FCPD-1003 Message , [FCPD-1003], ,, INFO, , Probing failed on which is possibly a private device which is not supported in this port type Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 288
32 FCPD-1003 212 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 289
for a Fibre Channel driver instance. The function can only be " fc_create". This function creates a Fibre Channel driver instance. The failed support authentication has tried to log in to the switch when the device authentication policy is in ON status on the switch. Recommended Action Enable - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 290
33 FCPH-1002 214 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 291
action is required. Action Severity INFO FCR-1003 Message , [FCR-1003], ,, INFO, ,FC router physical devices newly exported at port . Probable Cause Indicates that one or more physical devices have been newly exported through the specified - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 292
. Action Severity INFO FCR-1006 Message , [FCR-1006], ,, INFO, , FC router LSAN zone device added at port . Probable Cause Indicates that a device is added to a logical storage area network (LSAN) zone in the edge fabric. Recommended No - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 293
>,, INFO, , FC router LSAN zone enabled at port : . Probable Cause Indicates that a logical storage area network (LSAN) zone was enabled in the edge fabric attached to the specified port. The enabled LSAN zone configuration is listed. Recommended No action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 294
id () fabric ID . Probable Cause Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by a link or switch failure. Recommended No action is required. Action Severity INFO 218 Fabric OS Message Reference 53 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 295
to view how many proxy devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove, zoneDelete, cfgDelete, and cfgDisable in the edge fabric. Proxy devices can be removed by zoning operations or by bringing - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 296
consumed. Recommended Remove the proxy device slots by using the fcrProxyConfig command or limit proxy devices by Action removing logical storage area network a translate domain (which limits the number of translate domain ports required) by limiting the devices specified in logical storage area - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 297
that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical re-enabled. Severity INFO FCR-1027 Message , [FCR-1027], ,, INFO, , In slot port WWN - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 298
be disabled then re-enabled. Severity INFO FCR-1028 Port world wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected not in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 299
No action is required. Action Severity INFO FCR-1032 Message , [FCR-1032], ,, INFO, , Edge fabric enabled security on port in fabric . Probable Cause Indicates that Secure mode was turned on in the edge fabric. Recommended No - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 300
in the backbone fabric. Probable Cause Indicates that the specified logical storage area network (LSAN) zone was enabled in the backbone fabric. The enabled LSAN zone configuration is listed. Recommended No action is required. Action Severity INFO FCR-1037 Message , [FCR-1037 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 301
: . Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch&apos zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN) Action zones - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 302
contact your switch service provider. Severity ERROR FCR-1049 Message Probable Cause , [FCR-1049], ,, ERROR, , EX port () received an ELP command that is not supported. Indicates an incoming exchange link protocol (ELP) command was issued and - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 303
commands to enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , [FCR-1053], ,, WARNING, , Port - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 304
routing is not needed. Otherwise replace the switch with Action one that supports backbone to edge routing. Severity INFO FCR- command to modify the appropriate parameters on the local switch. Run the appropriate configuration command to modify the switch or port parameters on the remote switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 305
commands to restart authentication. Severity INFO FCR-1060 Message , [FCR-1060], ,, WARNING, , EX_Port() has an incompatible configuration setting. Probable Cause Indicates that virtual channel (VC) Link Init is enabled on the local switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 306
of supported EX_ports or VEX_ports was exceeded. To enable the specified port, disable any other operational port then re-enable the port. Cause Indicates that the fabric ID of the switch does not match the local switch. Recommended Run the switchShow command to display the fabric ID. Change the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 307
manually re-enable the port. If there is another fabric with the same ID, change the fabric ID for the port using the portCfgExport or portCfgVExport commands the fcrState set to 2 (disabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 308
set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity INFO FCR-1070 Message , [FCR-1070], ,, INFO, , The FC Routing configuration is set to default. Probable Cause Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 309
an earlier version of the switch in the backbone or edge that supports a different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits. Ensure - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 310
re-enable the port. Recommended Make sure to remain within the maximum of supported front domains. Action Severity ERROR FCR-1077 Message , [FCR-1077], ,, WARNING, , Port rejected fabric binding request/check from the M-Model switch; - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 311
that during the Coordinated HotCode protocol, a switch in the fabric did not accept the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended No action is required. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 312
remote control processor (CP) has earlier firmware, which does not support the FCR- based matrix while the local CP has the feature enabled. This is causing the loss of the high-availability (HA) synchronization. Recommended Disable FCR-based matrix or upgrade the remote CP. Action Severity ERROR - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 313
34 FCR-1087 Recommended Disable Condor2-based EX_ports or upgrade the remote CP. Action Severity ERROR FCR-1087 Message Disable the 'Allow to use XISL' mode of the domain by using the configure command. Action Severity ERROR FCR-1088 Message , [FCR-1088], ,, INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 314
-name>, FCR ELS trap entries exhausted. Probable Cause Indicates that the FCR ELS trap entries are exhausted. Recommended Collect supportsave data and send it to support. Action Severity ERROR 238 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 315
: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to. HP - Host Port number: This is a 1 byte hexidecimal value that represents the switch port of the switch that the FICON Channel is directly connected to. DD - Device Domain - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 316
Block ID Emulation Enabled or Disabled>. Probable Cause Indicates the configuration was changed manually. Recommended No action is required. Action Severity INFO FICN-1006 Message , [FICN-1006], ,, WARNING, , FICON GEPort < 0 or 1 - GE port number> TID - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 317
failure associated with this event, please contact your vendor's customer support Action for assistance. Severity ERROR FICN-1009 Message , [FICN CUADDR DeviceAddr> LastCmds= Sense Data:Bytes0-0xB= - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 318
the FICON Channel. Recommended If there was a job or IO failure associated with this event, please contact your vendor's customer Action support for assistance. Severity INFO FICN-1011 Message , [FICN-1011], ,, ERROR, , DevDiskIng:XRC Incorrect RRS SeqNum - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 319
that indicated device level exception. Recommended If there was an IO failure associated with this event, please contact your vendor's customer support Action for assistance. Severity INFO FICN-1015 Message , [FICN-1015], ,, ERROR, , DevEgr:cuPath=0x - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 320
with a FICON Control Unit CUADDR. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1019 Message , [FICN >8X8X LastCmd=0x8x LastStatus=0x - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 321
associated with this event, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1022 Message , status values received from the device> cmdArray=0x tflags=0x - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 322
CUADDR DeviceAddr>. Probable Cause Indicates the FICON channel issued a Purge Path command sequence for a device. Recommended If there IO Error associated with this event, contact your vendor's Action customer support for assistance. Severity INFO FICN-1027 Message Probable Cause , - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 323
IO Error associated with this event, contact your vendor's Action customer support for assistance. Severity ERROR FICN-1029 Message , [FICN-1029], current emulation state of the device> LastCmds=0x LastStatus=0x - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 324
HostPort DeviceDomain> . Probable Cause Indicates the peer side FICON Control Unit has accepted a logical path establishment command sequence with the FICON channel. Recommended No action is required. This is a part of the FICON path initialization. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 325
device/CU side processing. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1035 Message , . Probable Cause Indicates a locally connected FICON Channel issued an Establish Logical Path sequence to the specified FICON Control Unit - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 326
support for assistance. Severity ERROR FICN-1041 Message , [FICN-1041], ,, ERROR, , HostTapeEgr:AS Link Level Reject (LRJ) from CU Rx Path= LastCmd=0x - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 327
. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1042 Message , [FICN-1042 emulation state for this device> LastCmds=0x LastStatus=0x - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 328
If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING FICN-1046 Message , [ HostPort DeviceDomain> lastCmds=0x lastStatus=0x - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 329
peer. Recommended This is an unexpected event; contact your vendor's customer support for assistance. Action Severity WARNING FICN-1050 Message , [FICN . Probable Cause Indicates a PSF command has been received to initiate an XRC session with the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 330
Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity INFO FICN-1053 Message , [FICN-1053 . Probable Cause Indicates a PSF command has been received to withdraw from the XRC session with - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 331
Cause Indicates a suspend all devices from XRC session PSF command has been received to break an XRC session with the extended DASD device. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING FICN-1056 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 332
LPAR CUADDR DeviceAddr>. Probable Cause Indicates an internal issue has been encountered in the removal of an existing entry. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1062 Message , [FICN-1062 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 333
=0x. Probable Cause Indicates an abort operation has been received from a local FC interface for an exchange. Recommended If there were associated IO errors at the same time as this event, contact your vendor's customer Action support for assistance. Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 334
already in use Action or there is an internal memory leak, contact your vendor's customer support for assistance. Severity WARNING FICN-1067 Message , [FICN-1067], ,, the string for the nature of the configuration issue. 258 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 335
35 FICN-1070 Recommended If resolution of the configuration issue cannot be completed, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1070 Message , [FICN-1070], ,, INFO, , DevTapeIngr:Exceptional Status rcvd on Path=< - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 336
>:Emuls=0x:Cmds=0x:Chains=0x:MBytes= - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 337
>:Emuls=0x:Cmds=0x:Chains=0x:MBytes= - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 338
>:Emuls=0x:Cmds=0x:Chains=0x:MBytes= - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 339
VEPortNumber> Domain=0x Port=0x. Probable Cause Indicates an attached port which had a FICON emulated path established has logged out from the switch. Recommended This may be an unexpected event, contact your vendor's customer support for assistance. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 340
>,tunnel Id=. Probable Cause Indicates a FICON FCIP tunnel to the peer switch has been terminated. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR 264 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 341
this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on these commands. Severity ERROR FICU-1003 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 342
to core PID using the configure command and re-enable fmsMode using the ficonCupSet command. Refer to the Fabric OS Administrator's Guide for information on core PID mode and the Fabric OS Command Reference Manual for information on these commands. Severity WARNING FICU-1005 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 343
; then run the supportSave command and contact your switch service provider. Severity WARNING FICU-1008 Message , [FICU-1008], ,, WARNING, , FMS mode has been enabled. Ports: have been disabled due to port address conflict. Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 344
(FICON) Management Server mode (fmsMode) was not enabled because the specified port which has an address conflict with the CUP management port is in use. Recommended Use the portDisable command to disable the specified port to avoid the port address conflict. Action Severity WARNING FICU-1011 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 345
-1017], ,, WARNING, , FMSMODE enable failed because reserved area is bound to a device. Probable Cause Indicates one or both of the reserved areas 0xFE and 0xFF is bound to a device. Recommended Issue wwnaddress --show command to see all the devices currently bound to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 346
are swapped at the time of FMS Mode enable. Recommended Verify expected FICON Port Address / Port Number relationship. Action Severity WARNING FICU-1019 Message , [FICU-1019], ,, INFO, , Switch has been set offline by LP(%s). Probable Cause Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 347
-name>, Detected FC8-48 and/or FC8-64 that are not manageable when FMS mode is enabled. Probable Cause Indicates presence of unmanageable ports such as 48 port blade ports in Virtual Fabric disabled chassis. Recommended No action is required. Action Severity ERROR Fabric OS Message Reference - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 348
36 FICU-1022 272 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 349
WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 350
37 FKLB-1001 274 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 351
port number>, type Probable Cause Indicates that the link state record (LSR) type is unknown. The following two LSR header types are the only known support. Recommended Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two Action switches. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 352
38 FLOD-1006 Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended No action is required because the LSR is discarded. Action Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 353
Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended No action is required. Action Severity ERROR FSPF-1002 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 354
>, FSPF Version not supported, input port = Probable Cause Indicates that the FSPF version is not supported on the specified input port. Recommended Update the FSPF version by running the firmwareDownload command to update the firmware to the Action latest version. All - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 355
Recommended No action is required. Action Severity INFO 39 FSPF-1008 Fabric OS Message Reference 279 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 356
39 FSPF-1008 280 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 357
If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSS-1002 Message , [FSS-1002], , SLOT cp-slot-number | CHASSIS, WARNING, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 358
. If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR FSS-1005 Message , [FSS-1005], , SLOT cp-slot-number | CHASSIS, WARNING, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 359
supportShow/supportSave to validate the network configuration; then try to restore the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL FSS-1008 Message , [FSS-1008], , SLOT cp-slot - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 360
40 FSS-1011 FSS-1011 Message , [FSS-1011], , SLOT cp-slot-number | CHASSIS, INFO, , FSS Info: . Probable Cause Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 361
running the Reboot command), then no action is required. Otherwise, issue the haSyncStart command on the active command to diagnose the problem. If the problem persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 362
version. This causes a disruptive firmware upgrade or downgrade. Recommended For a dual CP system, run the firmwareDownload command to load compatible firmware on the Action standby CP. For details on this command, refer to the Fabric OS Command Reference Manual. Severity INFO 286 Fabric OS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 363
. Probable Cause Indicates that the internal temperature of the switch has changed. Recommended No action is required. Respond to this message as range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Severity WARNING FW - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 364
Value> . Probable Cause Indicates that the internal temperature of the switch has changed from a value outside of the acceptable range to a Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 365
>, is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the power supply counter changed from a value outside of the acceptable range to a value within the acceptable range. Recommended No action is required. Respond - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 366
, , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The receive performance area measures the amount of incoming laser to help you - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 367
>, is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has changed from a value outside of the acceptable range to a value within the acceptable range - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 368
Label>, is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has fallen below the low boundary. The transmit performance area measures the amount of outgoing laser - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 369
42 FW-1045 Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed from a value outside of the acceptable range to a value within the acceptable range. The transmit - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 370
42 FW-1048 Severity WARNING FW-1048 Message , [FW-1048], ,, INFO, , , is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the value of the small form-factor - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 371
SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 372
fabric reconfigurations has changed. The following actions can cause a fabric reconfiguration: • two switches with the same domain ID have connected to one another. • two fabrics have error and might not require troubleshooting. Severity INFO 296 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 373
boundary. The following occurrences can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to one another. • fabric reconfiguration might be a transient error and might not require troubleshooting. Severity INFO FW-1120 Message Probable Cause , [FW- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 374
changes has changed. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 375
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended No action is required - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 376
might occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. No action is required. Respond to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 377
42 FW-1129 Severity INFO FW-1129 Message , [FW-1129], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the number of zone changes has changed. Zone changes occur - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 378
Current value is . Probable Cause Indicates that the number of fabric logins has fallen below the low boundary. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. A low number of fabric logins means that the fabric is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 379
range to a value within the acceptable range. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric or removed. A low number of SFP state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 380
FW-1160], ,, INFO, , , , value has changed(High=, problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 381
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch failures that the port experiences has changed - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 382
. If you continue to experience synchronization loss errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity INFO FW-1165 Message , [FW-1165], ,, INFO, , , , is below low boundary(High= - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 383
of signal losses that the port experiences has changed. Loss of signal generally indicates a physical problem. Recommended Check both ends of that the switch is functioning normally. Severity INFO FW-1170 Message , [FW-1170], ,, WARNING, , , - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 384
number of protocol errors that the port experiences has fallen below the low boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. 308 Fabric OS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 385
Low value>). Current value is . Probable Cause Indicates that the number of invalid words that the port experiences has changed. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. Recommended Check both ends of your connections, your - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 386
number of invalid words that the port experiences has fallen below the low boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 387
policy of the Action end-user installation. A low number of invalid CRCs means that the switch is functioning normally. Severity INFO FW-1182 Message , [FW-1182], ,, WARNING, , , , is above high boundary(High=, Low= - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 388
High=, Low=). Current value is . Probable Cause Indicates that the percentage of incoming traffic that the port experiences has changed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 389
High=, Low=). Current value is . Probable Cause Indicates that the percentage of outgoing traffic that the port experiences has changed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 390
, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 391
has gone offline, has come online, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 392
that the switch is functioning normally. Severity INFO FW-1198 Message , [FW-1198], ,, WARNING, , , indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended Respond to this message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 393
Message , [FW-1201], ,, INFO, , , , is below low boundaries (High=, Low= - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 394
by adding more links to the trunk. Action Severity WARNING FW-1207 Message , [FW-1207], ,, INFO, , , , is between high and low boundaries (High=, Low=). Current value is . Probable Cause Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 395
=, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 396
High value>, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 397
that the number of end-to-end (EE) word frames that the switch transmits has changed from a value outside of the acceptable range to a value port receives has changed. The port has received small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 398
range. The port has received a small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a IP) addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 399
address. The TELNET_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 400
address. The HTTP_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish browser connections to the switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 401
from an unauthorized IP address. Recommended Action Run the errShow command to determine the IP address that sent switch connection control policy (SCC) violations has changed. SCC violations indicate that an unauthorized switch tried to join the fabric. The SCC_POLICY contains a list of switches - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 402
private loop devices not performing FLOGI is done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 403
private loop devices not performing FLOGI is done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 404
the specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports. DCC policies ensure that whenever a device has been detected. Recommended Action Run the errShow command to determine the IP location of the login attempt. Responses to security - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 405
FW-1343 Recommended Action Run the errShow command to determine the IP location of the login attempt. Responses to the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 406
in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 407
failures has changed. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly, or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 408
the low boundary. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 409
is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has fallen below the low boundary. Recommended No action is required. Action Severity INFO FW-1366 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 410
finds that there are no FCSs in the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 411
finds that there are no FCSs in the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 412
to a value within the acceptable range. This violation indicates the number of secure switches with different version stamps have been detected. When a switch is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible security - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 413
that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch where it is not allowed. Recommended Responses to security-class messages depend - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 414
switch as well as one security command that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 415
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended You might have to remove some unwanted files to create some flash space. Run the supportSave Action command to remove - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 416
Severity INFO FW-1424 Message Probable Cause , [FW-1424], ,, WARNING, , Switch status changed from to . Indicates that the switch status is not in a healthy state. This occurred because of a policy violation. 340 Fabric OS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 417
policy set by the switchStatusPolicySet command. Recommended Replace the faulty or missing power supply. Action Severity WARNING FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 418
absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the missing power supply. Action Severity WARNING FW - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 419
of faulty CPs is greater than or equal to the policy set by the switchStatusPolicySet command. The CPs are non-redundant. If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the micro-switch of the active CP before the heartbeat is up, this will cause both CPs to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 420
marginal ports and the port numbers> marginal ports. (Ports ) Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of marginal ports is greater than or equal to the policy set using the switchStatusPolicySet command. A port is faulty - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 421
command to modify the SFP policy or to add SFPs to the empty Action ports. Severity WARNING FW-1439 Message , [FW-1439], ,, WARNING, , Switch status change contributing factor Switch FRU is inserted but not powered on. Recommended No action is required. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 422
. The presence of an AP blade means that more than one power supply may be required to provide adequate power. So (even if the AP blade is powered down or removed) the Switch Status policy values will now reflect the need for 4 power supplies to maintain full (2X) redundancy. 346 Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 423
service indicates switch status is MARGINAL Recommended Action To maintain full (2X) redundancy and proper monitoring by Fabric Watch, 4 active power supplies should be supplied and the default values associated with the presence of an AP blade should be entered with switchStatusPolicyset command - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 424
loss of synchronization errors. Check the SFP and the cable. Then enable the Action port using the portEnable command. Severity INFO FW-1511 Message , [FW-1511], ,, INFO, , , , has crossed lower threshold boundary to in between(High - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 425
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot 1514], ,, INFO, , , , has dropped below upper threshold - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 426
Probable Cause Indicates that the number of signal losses that the port experiences has changed and crossed lower threshold boundary to a value within the acceptable range. Loss of signal generally indicates a physical problem. Recommended Action No action is required. Respond to this message as - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 427
Probable Cause Indicates that the number of invalid words that the port experiences has changed and crossed lower threshold boundary to a value within the acceptable range. Invalid words usually indicate a hardware problem with a small form-factor pluggable (SFP) or cable. Recommended No action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 428
faulty hardware. Verify that all optical hardware is clean. Severity INFO FW-1522 Message , [FW-1522], ,, INFO, , , , has crossed lower threshold boundary to in between(High=, Low=). Current value is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 429
has gone offline, has come online, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 430
E_Port, has become an F_Port, has segmented, or has become a trunk port. Recommended No action is required. Respond to this message as is appropriate to indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended Respond to this message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 431
Message , [FW-1532], ,, INFO, , , , has dropped below upper threshold boundary to in between(High , [FW-1534], ,, INFO, , , , has dropped below threshold boundary to in between(High - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 432
Name> class since FOS6.3. Disabling port fencing feature for this. Probable Cause Indicates that in previous versions portfencing is configured for Link/Sync loss, but after upgrading to new version, in which portfencing is not suppoted, resets the above bit. Recommended No action is required. You - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 433
42 FW-3013 Recommended No action is required. Action Severity WARNING FW-3013 Message , [FW-3013], ,, INFO, , , is below low boundary(High=, Low=). Current value is Probable Cause Indicates that the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 434
is above threshold. Recommended No action is required. Action Severity WARNING FW-3017 Message , [FW-3017], ,, INFO, , , is between high and low boundary(High=, Low=). Current value is Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 435
testing. Recommended No action is required. Action Severity WARNING FW-3021 Message , [FW-3021], ,, WARNING, , , is below low boundary(High=, Low=). Current value is Probable Cause Indicates the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 436
42 FW-3021 360 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 437
Recommended Reboot the standby CP blade by ejecting the card and reseating it. If the problem persists, replace Action the standby CP. Run the supportSave command and contact your switch service provider. Severity CRITICAL HAM-1002 Message , [HAM-1002], , SLOT cp-slot - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 438
43 HAM-1005 • Fastboot • Giveup Master:SYSM • CP Faulty:SYSM • FirmwareDownload • ConfigDownload:MS • ChangeWWN:EM • Reboot:WebTool • Fastboot:WebTool • Software Fault:Software Watchdog • Software Fault:Kernel Panic • Software Fault:ASSERT • Reboot:SNMP • Fastboot:SNMP • Reboot • Chassis Config • - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 439
auto-reboot is enabled, the system will automatically reboot itself. Otherwise you need to manually reboot it. Recommended For a reliable recovery, reboot the system manually if auto-reboot recovery is disabled. Run the Action supportSave command and contact your switch service provider. Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 440
is detected when system is not ready for warm recovery. Recommended Manually trigger reboot for cold recovery if needed, or wait until system CHASSIS, CRITICAL, ,Password database conversion failed. Probable Cause Indicates the password database conversion failed. Recommended No - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 441
-number | CHASSIS, CRITICAL, . Probable Cause Indicates a software watchdog detected termination of a restartable daemon and needed to reboot/failover. Recommended If needed manually initiate a reboot/failover. Action Severity CRITICAL Fabric OS Message Reference 365 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 442
43 HAM-1014 366 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 443
as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL HAMK-1002 Message , [HAMK-1002], , SLOT cp-slot-number | CHASSIS, INFO, , Heartbeat down. Probable Cause Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 444
44 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], , SLOT cp-slot-number | CHASSIS, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. This message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 445
the faulty blade or switch (for nonbladed switches). Action Severity ERROR command to verify the power supply status. Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 446
, and 4024, the entire switch must be replaced because these switches do not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100 , 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 447
area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. Fabric OS Message Reference - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 448
the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the fan continues to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 449
fan speed (in RPMs) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000. Recommended For the Brocade 4100, 4900, 7500, and AP7600, replace the fan field - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 450
-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity WARNING HIL-1302 Message , [HIL-1302], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 451
45 HIL-1305 Severity ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 452
have failed. This message is often preceded by a low fan speed message. Recommended Since the fans are not field replaceable, replace the switch if the temperature is high. Action Severity WARNING HIL-1311 Message , [HIL-1311], ,, INFO, , No fans are - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 453
45 HIL-1402 Probable Cause Indicates that one fan field-replaceable unit (FRU) has been removed. Recommended Install the missing fan FRU. Action Severity WARNING HIL-1402 Message , [HIL-1402], ,, WARNING, , Two fan FRUs missing. Install fan FRUs - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 454
Recommended Action Run the fanShow command to verify all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 455
Recommended Action Run the fanShow command to verify that all fans problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 456
. To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 457
. If any sensor is too high, monitor the switch. Try rebooting or power cycling the switch. Severity CRITICAL HIL-1603 Message , [HIL-1603], , FFDC, CRITICAL, , fans out of service. System is shutting down immediately. Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 458
the unit is faulty. Applicable only to Brocade 5100. Recommended Ensure that the power cord is connected to the unit with a valid power source and then switch on Action the unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. Severity WARNING HIL - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 459
HLO-1003], , FFDC, ERROR, , Invalid Hello received from port , Domain = , Remote Port =. Indicates that the HLO message received was invalid and the frame was dropped. The Brocade switch will not accept FSPF frames from the remote - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 460
an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 461
. Recommended Action Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 462
47 HMON-1001 386 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 463
Chapter HSL System Messages 48 HSL-1000 Message , [HSL-1000], ,, CRITICAL, , HSL initialization failed. Probable Cause Indicates an HSL initialization failure. Recommended No action is required. Action Severity CRITICAL HSL-1001 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 464
48 HSL-1004 Recommended No action is required. Action Severity INFO HSL-1004 Message , [HSL-1004], ,, ERROR, , Incompatible SFP for interface is detected. Probable Cause Indicates an incompatible SFP for the interface has been inserted. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 465
48 HSL-1007 Recommended Install more memory on board. Action Severity CRITICAL HSL-1007 Message , [HSL-1007], ,, ERROR, , Failed to read SFP for interface . Probable Cause Indicates a failure to read an SFP. Recommended No action is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 466
48 HSL-1007 390 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 467
>, [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that information on PID format, refer to the Fabric OS Administrator's Action Guide. Severity INFO HTTP-1002 Message , [HTTP-1002], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 468
49 HTTP-1003 392 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 469
Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Power off and power on the blade using the slotPowerOff and slotPowerOn commands. Action Severity ERROR Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 470
50 IBD-1001 394 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 471
name>, iSCSI login sessions exceed the maximum limit at slot port ge Probable Cause Indicates that the iSCSI login sessions exceed the supported limit per port. Recommended Use another port to log in. Action Severity WARNING Fabric OS Message Reference 395 53-1001767 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 472
51 IBPD-1003 396 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 473
Action Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. Severity ERROR ICPD-1002 Message < -name>, iSNS Client service is detected on multiple switches in fabric. Indicates the iSNS Client service is enabled on multiple switches in the fabric. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 474
to the Fabric OS Action Command Reference for more information on this command. Severity WARNING ICPD-1006 Message , [ICPD-1006], ,, INFO, , iSCSI service is on the switch. Probable Cause Indicates the iSCSI service is enabled or disabled on the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 475
Recommended No action is required. Action Severity INFO 52 ICPD-1008 Fabric OS Message Reference 399 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 476
52 ICPD-1008 400 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 477
entity> . Probable Cause Indicates that a change in the gateway IP address has occurred. If the source of the address change is manual, this means that the address change was initiated by a user. If the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 478
53 IPAD-1001 402 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 479
FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING IPS-1004 Message , [IPS-1004], ,, WARNING, , Port Config Mode Mismatch slot () port(ge): current mode is () Fabric - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 480
the remote side to set up Action the tunnel. Severity WARNING IPS-1006 Message , [IPS-1006], ,, WARNING, , Tunnel Configuration Mismatch for slot () port() tunnel ID() reason () Probable Cause Indicates that tunnel - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 481
[ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates the specified port has crashed. Recommended No action is required; the port will restart automatically. Action Severity ERROR Fabric OS Message Reference - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 482
55 ISCS-1000 406 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 483
slot/port /ge (current /ge). Probable Cause Indicates that the user has issued the isnscCfg command. Recommended No action is required - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 484
, Start re-register with external iSNS server slot/port /ge. Probable Cause Indicates that the re-register with the specified external internet storage name service (iSNS) server has started. Recommended No action is required. Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 485
Peering with external iSNS server not started because no virtual targets manual for valid slot and Action port ranges. Severity WARNING ISNS-1011 Message , [ISNS-1011], ,, INFO, , iSNS Client Service is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 486
Indicates that the internet storage name service (iSNS) client failed to establish a connection with the iSNS server. Recommended Verify the connection of the iSNS server to the slot or port. Use the isnscCfg command to display or Action correct the server IP address. Severity WARNING ISNS-1014 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 487
key vault. Recommended Determine whether the configured key vault is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the vault. Severity ERROR KAC-1004 Message , [KAC-1004], ,, ERROR, , KAC - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 488
vault. Recommended Determine whether the configured key value is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the vault. Severity ERROR KAC-1008 Message , [KAC-1008], ,, ERROR, , Putting - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 489
. An abort signal is sent. Recommended Copy the warning message along with any core file information, and contact your switch service Action provider. Severity WARNING KSWD-1002 Message , [KSWD-1002], , FFDC, WARNING, , Detected termination of - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 490
58 KSWD-1002 414 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 491
Message , [KTRC-1003], ,, ERROR, , Cannot open ATA dump device Probable Cause Indicates the ATA dump driver is not initialized properly. Recommended No action is required. Action Severity ERROR KTRC-1004 Message Probable Cause , [KTRC-1004 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 492
59 KTRC-1005 Recommended No action is required. Action Severity ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 493
>,, ERROR, , Message Queue Error : Message queue create failed. Probable Cause Indicates that the l2sys encountered with System Service Manager (SSM) message queue errors. Recommended Restart the l2sysd daemon. Action Severity ERROR L2SS-1004 Message Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 494
60 L2SS-1005 Recommended Restart the l2sysd daemon. Action Severity ERROR L2SS-1005 Message , [L2SS-1005], ,, ERROR, , Mac-address-table hash failed even after two attempts for slot chip . Probable Cause Indicates a mac-address-table hash - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 495
initialization of a module within the LACP daemon has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR Fabric OS Message Reference 419 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 496
61 LACP-1001 420 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 497
1000 Message , [LANCE-1000], ,, ERROR, , Slot Port GE : Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the port is disabled. Recommended No action is required. Action Severity ERROR Fabric OS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 498
62 LANCE-1000 422 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 499
Manager service is enabled by the factory setting and it is not user configurable. Recommended No action is required. Action Severity INFO LFM-1003 Message , [LFM-1003], ,, INFO, , The Logical Fabric Manager configuration is set to default. Probable - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 500
. Check the reason for the port disable using the Action switchshow command. Rectify the disable based on the reason. Severity WARNING LFM-1006 Message , [LFM-1006], ,, WARNING, , The switch with domain with firmware version has joined - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 501
. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING LOG-1002 Message , [LOG-1002], , FFDC, WARNING, , A log message was - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 502
64 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 426 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 503
The switch will discard the record because it is not supported. enabled. By disabling and enabling the switch, a new local link state record is generated. Recommended Run the switchDisable and switchEnable commands. A new local link state record is generated Action during the switch enable - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 504
for domain Probable Cause Indicates there is no link state record for the specified local domain. Recommended No action is required. The other switch will pass the LSD once the fabric is stable. Action Severity WARNING 428 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 505
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MFIC-1002 Message , [MFIC-1002], ,, INFO, , Chassis FRU header not programmed for switch NID, using defaults (applies only to FICON environments - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 506
mode as the fabric. If you are enabling or disabling IDID mode, this message is for information purposes only, and no action is required. IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure Tab > Fabric Subtab > Insistent Domain - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 507
Chapter MPTH System Messages 67 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Cause Indicates a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 508
67 MPTH-1003 432 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 509
Chapter MQ System Messages 68 MQ-1004 Message , [MQ-1004], ,, ERROR, , mqRead, queue = , queue ID = , type = Probable Cause Indicates an unexpected message has been received in the specified message queue. The queue - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 510
68 MQ-1006 MQ-1006 Message , [MQ-1006], ,, WARNING, , queue : msg too long (:) Probable Cause Indicates the incoming message size is larger than the message queue size. Recommended No action is required. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 511
Cause Indicates the management server (MS) has segmented from another switch domain at the specified port number because of errors or inconsistencies defined in the MS platform service. Recommended Restart or power cycle the switch. Action Severity WARNING MS-1002 Message , [MS-1002 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 512
=BUSY) by> Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. • Wait a few minutes and try the command again. Severity INFO MS-1003 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 513
. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MS-1008 Message , [MS-1008], ,, ERROR, , MS Failure while initializing - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 514
system-name>, RLIR event. Switch Port ID is (). Device Port Tag is . . are likely the result of SAN hardware problems such as bad cables or ; then run the Action supportSave command and contact your switch service provider. Severity ERROR MS-1022 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 515
Cause Indicates the management server (MS) has disabled E-port port number connected to domain domain because implicit enable operation of platform service is blocked. Recommended Enable Platform service on the switch and renable the port to join the fabric. Action Severity WARNING Fabric OS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 516
69 MS-1026 440 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 517
If this is a bladed switch, execute the haFailover command. If the problem persists or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR MSTP-2001 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 518
70 MSTP-2002 Recommended No action is required Action Severity INFO MSTP-2002 Message , [MSTP-2002], ,, INFO, , . My Bridge ID: Old Root: New Root: Probable Cause Indicates that the MSTP - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 519
70 MSTP-2006 Recommended No action is required. Action Severity INFO MSTP-2006 Message , [MSTP-2006], ,, INFO, , MSTP instance brigde priority is changed from to . Probable Cause Indicates that the MSTP instance - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 520
70 MSTP-2006 444 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 521
Wait • 4 - Database Wait • 5 - Full If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then this message can - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 522
in state , input , port Probable Cause Indicates the database transmit set flag - Full Recommended No action is required. The Fabric OS automatically recovers from this problem. Action Severity WARNING 446 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 523
larger than the max frame size the remote switch can support! Probable Cause Indicates the response payload exceeds the maximum frame size the remote switch can handle. Recommended Action Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, or v3.2 or higher - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 524
firmware versions running on the active and standby CPs. This means that the active and standby CPs are out of sync. Any execution of the haFailover or firmwareDownload commands size to 1024 or smaller, or upgrade the software of the remote switch to support Action 2048 zones. Severity WARNING NS- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 525
or relocate Open FR devices to a licensed switch. Action Severity WARNING NS-1009 Message , [NS-1009], ,, WARNING, , NS has detected a device with node wwn as zero, pid 0x. Probable Cause Indicates that a port has logged in with node wwn as - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 526
in fabric id . Probable Cause Indicates that a failover flag has disabled TI zone in a base switch fabric. Recommended Modify failover flag to enable or remove TI zone with failover flag disabled since the routing may not Action be setup correctly. Severity WARNING 450 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 527
Recommended Check for the reason codes using the show interface command and resolve the protocol Action dependencies. Severity INFO NSM-1003 [NSM-1004], ,, INFO, , Creating a Port-Channel interface . Indicates that the new Portchannel interface has - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 528
Vlan name> is in use. First remove all the FCoE sessions of its member ports and then try again to disable it. Probable Cause Indicates that the FCoE VLAN is . Probable Cause Indicates the chassis is disabled or enabled. Recommended No action is required. Action Severity INFO NSM-1008 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 529
73 NSM-1009 Recommended No action is required. Action Severity INFO NSM-1009 Message , [NSM-1009], ,, INFO, , Interface is deleted. Probable Cause Indicates that the logical interface has been deleted. Recommended No action is required. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 530
73 NSM-1013 Recommended No action is required. Action Severity INFO NSM-1013 Message , [NSM-1013], ,, INFO, , Vlan classifier group is deleted. Probable Cause Indicates that Vlan classifier group has been deleted. Recommended No action is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 531
73 NSM-1017 Recommended No action is required. Action Severity INFO NSM-1017 Message , [NSM-1017], ,, INFO, , Interface is on interface . Probable Cause Indicates that logical interface member list has been - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 532
Enable the DCE ports after bringing up the core blades. Action Severity INFO NSM-1022 Message , [NSM-1022], ,, WARNING, , . Probable Cause Indicates internal error information. Recommended To be transmitted to engineering for problem - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 533
Messages 74 ONMD-1000 Message , [ONMD-1000], ,, INFO, , LLDP is enabled. Probable Cause Indicates that LLDP is globally enabled. Recommended No action is required. Action Severity INFO ONMD-1001 Message , [ONMD-1001], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 534
74 ONMD-1004 Recommended No action is required. Action Severity INFO ONMD-1004 Message , [ONMD-1004], ,, INFO, , LLDP is disabled on interface . Probable Cause Indicates that LLDP is disabled on interface. Recommended No action is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 535
process. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 536
entries. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1007 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 537
PDM-1008 Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1008 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 538
empty. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1014 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 539
command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service , , Failed to download area port map. Fabric OS Message Reference 463 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 540
command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service for IPv6 addresses. IPv6 is not supported by older firmware. Recommended Configure the Radius server - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 541
a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved. Recommended Run the pdShow command to view the panic dump and core dump files. Action Severity INFO PDTR-1002 Message , [PDTR-1002], ,, INFO, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 542
76 PDTR-1002 466 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 543
issuing the reboot command from a command-line prompt. Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service solve the problem. If Action the problem still persists, then replace the CP. Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 544
PLAT-1003 Message , [PLAT-1003], , FFDC, CRITICAL, , Slot C/BE: ADBUS: misc_intr . Probable Cause Indicates a PCI bus hang was detected - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 545
Severity WARNING PMGR-1003 Message , [PMGR-1003], , INFO, , Attempt to delete switch succeeded. Probable Cause Indicates that the switch with the specified FID was successfully deleted. Recommended No action is required. Action Severity INFO PMGR - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 546
No action is required. Action Severity INFO PMGR-1006 Message , [PMGR-1006], , WARNING, , Attempt to move port(s) on slot to switch failed. Error message: . Probable Cause Indicates the unsuccessful attempt to move the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 547
Cause Indicates the failed attempt to change the base switch. Recommended No action is required. Action Severity WARNING PMGR-1011 Message , [PMGR-1011], , INFO, , Attempt to move ports to switch succeeded. Probable Cause Indicates the successful - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 548
78 PMGR-1011 472 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 549
some buffers and allow this port to be enabled. Severity INFO PORT-1005 Message Probable Cause , [PORT-1005], ,, WARNING, , Slot port does not support configured L_port. Issue portCfgLport to clear configuration. Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 550
Recommended No action is required. Action Severity INFO PORT-1008 Message , [PORT-1008], ,, INFO, , GigE Port (ID: ) has been enabled. Probable Cause Indicates a GbE port has been enabled. Recommended No action is required. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 551
Recommended No action is required. Action Severity INFO PORT-1010 Message , [PORT-1010], ,, WARNING, , Port (ID: ) QOS is disabled. Probable Cause The Port QOS is disabled because the port currently has Best Effort Setting that requires QOS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 552
79 PORT-1010 476 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 553
not happen, restart Action or power cycle the switch to re-initiate the firmware. Severity CRITICAL PS-1001 Message action is required. Refer to the Fabric OS Administrator's Guide for more information on the PID Action format. Severity ports. Fabric OS Message Reference 477 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 554
one ISL port. Recommended No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is Action enabled. ISL monitoring switch. Probable Cause Indicates the end-to-end monitors are configured on the switch. Recommended Delete the end-to-end monitors on that switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 555
WARNING, , Failed to add fabricmode toptalker on domain=. . Probable Cause Indicates that FCR or McData mode is enabled on this particular fabric. Recommended Action No action required. Top Talker cannot be installed on fabric with FC router or McData mode - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 556
80 PS-1007 480 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 557
command has been issued. Recommended No action is required. Action Severity INFO PSWP-1002 Message , [PSWP-1002], ,, INFO, , Port Swap feature enabled. Probable Cause Indicates that the portSwap feature has been enabled in the switch. Recommended - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 558
Cause Indicates that the bladeSwap command has been issued. Recommended No action is switch number . Probable Cause Indicates that the bladeSwap command has failed to access the switch context. Recommended Retry the command. If the failure persists, contact your support - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 559
Probable Cause Indicates that the maximum storage size for FFDC data capture is reached. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1004 Message , [RAS-1004], , FFDC, WARNING, , Software - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 560
Indicates an internal software error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support data file () automatically transferred to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 561
INFO RAS-3002 Message , [RAS-3002], , INFO, , USB storage device enabled. Probable Cause Indicates that the USB storage device is enabled. Recommended No action is required. Action Severity INFO RAS-3003 Message , [RAS-3003], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 562
82 RAS-3004 Recommended No action is required. Action Severity INFO 486 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 563
later, and v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message , [RCS-1002], ,, INFO, , RCS has been enabled. Probable Cause Indicates that the RCS feature has - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 564
.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message might not be compatible or the domain does not have the license to support that application. Recommended Action If the reject is in ACA phase - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 565
1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates that a domain cannot handle the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 566
83 RCS-1008 490 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 567
Chapter RKD System Messages 84 RKD-1001 Message , [RKD-1001], ,, INFO, , operation .\nTarget: , Initiator: - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 568
84 RKD-1004 RKD-1004 Message , [RKD-1004], ,, INFO, , Message: . Probable Cause Indicates the generic rekey message. Recommended No action is required. Action Severity INFO RKD-1005 Message , [RKD-1005], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 569
Chapter RMOND System Messages 85 RMON-1001 Message , [RMON-1001], ,, INFO, , RMON rising threshold alarm from SNMP OID . Probable Cause Indicates that the threshold level has exceeded for the sample type of RMON alarm. Recommended Check the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 570
85 RMON-1002 494 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 571
-name>, Authentication Error: client \"\" has bad credentials: Probable Cause Indicates an certificate is missing. Recommended To enable RPCD in secure mode, install a valid SSL certificate on the switch. Action Severity WARNING RPCD-1003 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 572
has been corrupted. Recommended To enable RPCD in Secure mode, install a valid SSL certificate in the switch. Action Severity WARNING RPCD-1005 the private key file has been corrupted. Recommended Run the pkiCreate command to install a valid private key file. Action Severity WARNING 496 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 573
see if the specified domain ID is online. Enable the switch with the specified domain ID. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity WARNING Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 574
a response. Recommended Action Run the dom command to verify that the specified domain ID is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity INFO 498 Fabric OS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 575
88 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= fn= oid - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 576
88 SAS-1001 500 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 577
complete listing, see the Introduction to this manual. • fabricd • asd • evmd • command to send the core files using FTP to a secure server location. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 578
89 SCN-1001 502 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 579
in the fabric to be enabled. If all switches are capable, RCS is automatically enabled. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1002 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 580
to the fabric. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING SEC-1005 Message , [SEC-1005], ,, INFO, , Primary - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 581
establish API connection. Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the API connection. Action Severity INFO SEC-1008 Message , [SEC - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 582
objects exist on the switch. If the private key does not exist, follow the steps for re-creating PKI objects, outlined in the Secure Fabric OS Administrator's Guide. If a certificate does not exist or is invalid, install the certificate by following the field upgrade process. Severity WARNING SEC - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 583
-1025], ,, ERROR, , Invalid IP address () detected. Probable Cause Indicates a corruption occurred during Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 584
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the sync. Probable Cause Indicates the security database size is not supported by the standby control processor (CP). Recommended Reduce the security - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 585
in the secPolicyAdd command. Only the secPolicyCreate command supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the switch connection control - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 586
in the policy member list had an invalid format. Recommended Run the command again using the standard WWN format, 16 hexadecimal digits grouped as eight Invalid portlist (). Cannot combine * with port member in the same portlist. Probable Cause Indicates the port list contains the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 587
Severity ERROR SEC-1041 Message , [SEC-1041], ,, ERROR, , Invalid port member in portlist (). . Probable Cause Indicates the port member is invalid for one of the following reasons: • The value is not a number. • The - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 588
SEC-1045], ,, ERROR, , Too many port members. Probable Cause Indicates there has been a corruption during the Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 589
Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the switch. Severity ERROR SEC-1051 Message , [SEC-1051], ,, ERROR, , Missing brace for port list - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 590
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 591
to flash. Probable Cause Indicates the operation failed when writing to flash. Recommended Run the supportFtp - e command to FTP files from the switch and remove them from the flash. Action Severity ERROR SEC-1062 Message , [SEC-1062], ,, ERROR, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 592
number supported are switch are not in a valid state and the signature operation failed. Recommended Run the pkiShow command to verify that all PKI objects are valid. If PKI objects are not valid, Action generate the PKI objects and install the certificate by following the field upgrade - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 593
for unknown reasons. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1073 Message , [SEC-1073], ,, ERROR, , No FCS policy in - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 594
the operation in non-secure mode. In secure mode, run the command from a switch that has required privilege, that is, either a backup FCS or primary able to communicate with others nodes in the zone. Recommended Re-enable the current zone configuration for the change to take effect. Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 595
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 596
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 597
1088], ,, ERROR, , Cannot execute the command. Please try later. Indicates there has been a corruption during the configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 598
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 599
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 600
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR SEC-1098 Message , [SEC-1098], ,, ERROR, , No FCS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 601
. Probable Cause Indicates the security enable failed on the fabric because one or more switches in the fabric are busy. Recommended Action Verify that the security event was planned. If the security event was planned, run the secFabricShow command to verify that all switches in the fabric are in - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 602
by following the procedure specified in the Secure Fabric OS Administrator's Guide. Severity ERROR SEC-1105 Message , [SEC-1105], < secFabricShow to verify that all switches in the fabric are in the ready state. Retry the Action command when all switches are READY. Severity ERROR - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 603
Verify that the security event was planned. If the security event was planned, run the secFabricShow command to verify that all switches in the fabric are in the ready state. When all switches are in the ready state, retry the operation. Severity ERROR SEC-1110 Message , [SEC-1110 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 604
Make sure that the new FCS policy is the same as the current FCS policy on the switch. Action Severity ERROR SEC-1113 Message , [SEC-1113], ,, WARNING, , [ license ] going to expire in days. Probable Cause Indicates the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 605
the data received by the primary fabric configuration server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user authentication data. Recommended Run the secFabricShow command to verify that all switches in the fabric are in the ready state. Action When - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 606
problem is transient. Retry the command. Action Severity INFO SEC-1119 Message , [SEC-1119], ,, INFO, , Secure mode has been enabled. Probable Cause Indicates the secure Fabric OS was enabled by the secModeEnable command time on the switch is not - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 607
INFO SEC-1130 Message , [SEC-1130], ,, INFO, , The Primary FCS has failed over to a new switch. Probable Cause Indicates an FCS failover operation was completed successfully. Recommended Action Verify the security event was planned. If the security - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 608
time service, or the signature verification failed. Signature verification failure indicates either an internal error (such as losing the primary public key) or an invalid database. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 609
time service, or the signature verification failed. Signature verification failure indicates either an internal error (such as losing the primary public key) or an invalid database. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 610
. • The passwords have changed for switches in the fabric to be enabled. If all switches are capable, it is automatically enabled. For any switch that does not support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 611
database exceeds the maximum size. This message can also be caused when the switch is short of memory. The status values can be either defined, active, fabric. Make sure to wait a few minutes between executing commands so that your commands do not overlap in the fabric. Severity INFO SEC-1157 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 612
; then run the supportSave command and contact your switch service provider. Severity INFO SEC-1158 port in port list (). Probable Cause Indicates a duplicate port member exists in the specified port list. Recommended Verify that there is no duplicate member in the port - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 613
[SEC-1165], ,, ERROR, , Low memory, failed to enable security on all switches. Probable Cause Indicates the system is low on memory. Recommended Wait a few minutes and try the command again. Action Severity ERROR SEC-1166 Message , [SEC-1166], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 614
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 615
pkiCreate command to create them for the switch. Run the licenseAdd command to install the required license key. Refer to your switch supplier to obtain a license if Failed to set password. Indicates the FCS or non-FCS password could not be set. Fabric OS Message Reference 539 53- - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 616
number>,, ERROR, , Failed to install zone data. Probable Cause Indicates the zone database could not be installed on the switch. Recommended Verify all switches in the fabric are in time synchronization with the primary and that no external Action entity is trying to access the fabric - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 617
>,, ERROR, , Policy to binary conversion error: Port is out range. Probable Cause Indicates a security database set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1184 Message , [SEC - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 618
switch database was enabled or disabled as the secondary authentication, accounting, and authorization (AAA) mechanism when the Remote Authentication Dial-in User Service node name> tries to FLOGI to index/area of switch . Indicates a device connection control (DCC) security - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 619
Severity INFO SEC-1190 Message , [SEC-1190], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP read operation. Probable Cause Indicates an SNMP security violation was reported. The specified unauthorized host - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 620
lists the violating IP address. Verify that this IP address is being used by a valid Action switch admin. Use the correct password. Severity INFO Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 621
Switch does not have all default account names. Probable Cause Indicates the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Reset the default Security violation: Unauthorized host with IP address tries to establish API connection - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 622
so, add the host IP address to the API serial port of switch . command was forwarded from a non-primary fabric configuration server (FCS) switch. Recommended Action Check the MS policy and verify that the connection is allowed. If the connection is allowed but not specified, enable - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 623
name>, device port name . Probable Cause connection is allowed but not specified, enable the connection in the MS policy. RSH. IP Addr: Probable Cause Indicates the IP address of run the supportSave command and contact your switch service provider. Severity WARNING - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 624
; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1253 switch is in interop mode. Security is not supported. Probable Cause Indicates the switch is interop-mode enabled. Recommended Disable interop-mode using the interopMode command before enabling - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 625
currently installed software version does not support the Brocade Secure Fabric OS feature. Recommended Run the firmwareDownload command to update the firmware to the latest version for your specific Action switch. Verify the firmware you are installing supports the Brocade Secure Fabric OS feature - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 626
command and verify that all public key infrastructure (PKI) objects exist on the switch. If a failure to validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide in user service (RADIUS/LDAP) server responded to a switch request. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 627
commit service (RCS enable failed on the fabric because one or more switches in the fabric have password policies that are not set to the default value. Recommended Action Verify the security event was planned. If the security event was planned, run the passwdCfg --setDefault command on each switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 628
parameters were set to default values. Probable Cause Indicates the passwdCfg parameters were set to default values. Recommended Action Verify retrieve the IP address failed. Recommended Restart the system to fix this error. If the problem persists contact your switch service provider. Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 629
to the fabric, as specified by Domain Number, have a conflicting policy with the local switch. Recommended Check the conflicting policy and make the new swithces and the local switch policies the same. Action Severity WARNING SEC-1317 Message , [SEC-1317], ,, INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 630
secure mode enable command. Reason: . Probable Cause Indicates the security enable failed on the fabric because the switch has a conflicting support a device connection control (DCC) policy with more than 256 ports. Recommended Reconfigure any policy that includes more than 256 ports - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 631
. RCS error: Probable Cause Indicates the reliable commit service (RCS) transaction failed with the specified reason code. Recommended Verify the >,, ERROR, , Security enforcement: Switch connecting to port is not authorized to stay in fabric - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 632
with the fabric, then resolve the issue by making the conflicting policies the same IP filter policy enforcement failed due to internal system failure. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 633
ERROR, , Attempt to enable secure mode failed. Reason: . Probable Cause Indicates the secModeEnable command failed on the fabric because default IP Filter policies are not active on the switch, or an active transaction exists on IP Filter policies. Recommended Action Verify - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 634
-number>, AUDIT, INFO, , Event: ipfilter, Status: failed, Info: Failed to save changes for ipfilter policies. Probable Cause Indicates that that the specified IP filter policy has not been saved. Recommended Action Verify that the security event was planned. If the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 635
The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through , AUDIT, INFO, , The license key is . Indicates that a license key is added or removed. Fabric OS Message Reference 559 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 636
90 SEC-3061 Recommended No action is required. Action Severity INFO SEC-3061 Message , [SEC-3061], , AUDIT, INFO, , Role is created. Probable Cause Indicates a role name was created. Recommended No action is required. Action Severity INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 637
is required. Action Severity INFO SEC-4001 Message , [SEC-4001], , AUDIT, INFO, , Client logged in . Probable Cause Indicates the client has logged in. Recommended No action is required. Action Severity INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 638
90 SEC-4001 562 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 639
Message , [SFLO-1002], ,, INFO, , sFlow is for port . Probable Cause Indicates that the sFlow is enabled or disabled for a particular port. Recommended No action is required. Action Severity INFO SFLO-1003 Message , [SFLO-1003 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 640
is changed to . Probable Cause Indicates that the polling interval has changed on the port. Recommended No action is required. Action Severity INFO SFLO-1007 Message , [SFLO-1007], ,, INFO, , is as as sFlow - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 641
Recommended No action is required. Action Severity INFO 91 SFLO-1008 Fabric OS Message Reference 565 53-1001338-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 642
91 SFLO-1008 566 Fabric OS Message Reference 53-1001338-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 643
(SNMP) service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Recommended Verify the IP address for (SNMP) service has failed and you will not be able to query the switch through SNMP. Recommended Restart or power cycle the switch. This - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 644
and the SNMP service will not work correctly. Recommended Change the SNMP configuration back to the default. Action Severity ERROR and new values for that parameter. Recommended Execute the snmpConfig --show command to see the new configuration. Action Severity INFO SNMP-1006 Message < - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 645
-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Execute the nsshow command to view the current device status. Action Severity INFO Fabric OS Message Reference 569 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 646
92 SNMP-1008 570 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 647
containing Encryption Engine>, Cryptographic operation enabled. Probable Cause Indicates the cryptographic operation is enabled on an encryption engine. Recommended slotpoweron commands on the blade to recover the system. For a non-bladed system, perform a fastboot command on the switch to recover - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 648
SPC-2004 Message , [SPC-2004], ,, ERROR, , , : FPGA firmware download failed: 0x%x. Probable Cause Indicates the FPGA download has failed. Recommended No action is required. Action Severity ERROR - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 649
SPC-2005 Message , [SPC-2005], ,, INFO, , , : FPGA firmware download success: 0x%x. Probable Cause Indicates the FPGA download was successful. Recommended No action is required. Action Severity INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 650
Cause Indicates the Tamper event triggered due to a user zeroize request. Recommended EE is zeroized. Run the initEE and regEE commands. Action Severity CRITICAL SPC-2010 Message , [SPC-2010], ,, CRITICAL, , - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 651
93 SPC-3001 SPC-3001 Message , [SPC-3001], ,, ERROR, , , : No input KEK for DEK inject, DEK: , KEK: - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 652
format • 32 - DEK could not be unwrapped • 33 - FGPA error upon inject • 73 - Invalid KEK format Recommended Contact technical support. Action Severity ERROR SPC-3006 Message , [SPC-3006], ,, ERROR, , , - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 653
• 73 - Invalid KEK format • other - Internal error Recommended For status code 14, complete primary KEK generation; otherwise, contact technical support. Action Severity ERROR SPC-3008 Message , [SPC-3008], ,, INFO, , - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 654
using the Secret Encryption Key failed most likely, the EE has been zeroized or tampered with. Recommended Run the initEE and regEE commands, then recover or restore the needed primary and secondary Action KEKs. Severity ERROR SPC-3012 Message , [SPC-3012], ,, ERROR - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 655
: successive values match. Probable Cause Indicates the Crypto Module internal random number generator has failed. Recommended Contact technical support. Action Severity ERROR SPC-3015 Message , [SPC-3015], ,, ERROR, , - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 656
93 SPC-3015 580 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 657
resources and restart the switch. Action Severity ERROR based on the reason displayed. Recommended Run the supportsave command to gather information. Action Severity WARNING SPM-1003 Message , [SPM-1003], ,, INFO, , Set New Group Cfg SC Enable - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 658
94 SPM-1005 Recommended No action is required. Action Severity INFO SPM-1005 Message , [SPM-1005], ,, INFO, , Set EE Control slot action . Probable Cause Indicates encryption engine (EE) control slot configuration. Recommended No action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 659
ERROR, , Certificate is missing. Probable Cause Indicates that a certificate is missing. Recommended Run the cryptocfg --initnode command. Action Severity ERROR SPM-1010 Message , [SPM-1010], ,, ERROR, , Key Vault Certificate - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 660
configured. Recommended Import required MK(s) using cryptocfg --recovermastekey command to bring EE online. Action Severity WARNING SPM-1015 security database. Recommended Use cryptocfg --sync -securitydb to manually sync security db. Action Severity WARNING SPM-3001 Message Probable - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 661
>, [SPM-3004], ,, INFO, ,Event: cryptocfg Status: success, Info: EE in slot enabled. Probable Cause Indicates an encryption engine was enabled. Recommended No action is required. Action Severity INFO SPM-3005 Message Probable Cause , [SPM-3005 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 662
Message , [SPM-3008], ,, INFO, ,Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Probable Cause Indicates a DH challenge was generated for a key vault. Recommended No action is required. Action Severity INFO SPM-3009 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 663
-name>,Event: cryptocfg Status: success, Info: key vault registered. Certificate label: \"\" Certificate file: \"\" IP address: . Probable Cause Indicates a key vault was registered. Recommended No action is required. Action Severity INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 664
94 SPM-3014 Recommended No action is required. Action Severity INFO SPM-3014 Message , [SPM-3014], ,, INFO, ,Event: cryptocfg Status: success, Info: Key archive client registered with certificate file \"\". Probable Cause Indicates a KAC - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 665
94 SPM-3018 Recommended No action is required. Action Severity INFO SPM-3018 Message , [SPM-3018], ,, INFO, ,Event: cryptocfg Status: success, Info: master key recovered. Probable Cause Indicates a master key was recovered. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 666
>,, INFO, ,Event: cryptocfg Status: success, Info: System card . Probable Cause Indicates use of the system card was enabled or disabled. Recommended No action is required. Action Severity INFO SPM-3024 Message , [SPM-3024], ,, INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 667
94 SPM-3026 Recommended No action is required. Action Severity INFO SPM-3026 Message , [SPM-3026], ,, INFO, ,Event: cryptocfg Status: success, Info: File exported via usb: Source: Destination: . Probable Cause Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 668
94 SPM-3029 Recommended No action is required. Action Severity INFO 592 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 669
SS-1000], ,, INFO, , supportSave has uploaded support information to the host with IP address . Probable Cause Indicates the supportSave command was used to transfer support information to a remote location. Recommended No action is required. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 670
command. Recommended Run the usbstorage command to check the USB storage device settings. After the USB problem is Action corrected, rerun the supportSave command No IP connection. Probable Cause Indicates the IP switch and then run the supportsave command. Action 594 Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 671
Indicates no reponse from the blade in the corresponding slot for the given supportsave request. Recommended Reboot the switch and then run the supportsave command. Action Severity WARNING SS-1008 Message , [SS-1008], ,, WARNING, , supportsave failed for - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 672
95 SS-1008 596 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 673
Action Check the memory usage on the switch using the memShow command. Restart or power cycle the switch. Severity ERROR SSMD-1002 Message < new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 674
and initialization. Recommended Action Restart or power cycle the switch .If the condition persists then download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR SSMD-1200 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 675
number> / . Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in initializing the dataplane ASIC QoS infrastructure. Recommended Restart or power cycle the switch. Action Severity WARNING SSMD-1205 Message , [SSMD-1205 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 676
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface Default CoS feature. Recommended Delete and reapply the QoS interface Default CoS policy. Restart or power cycle the switch. Action Severity WARNING SSMD - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 677
the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the CoS to Traffic Class mapping feature. Recommended Delete and reapply the QoS interface CoS to Traffic Class policy. Restart or power cycle the switch. Action Severity WARNING - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 678
Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface Pause feature. Recommended Delete and reapply the QoS Pause policy. Restart or power cycle the switch. Action Severity WARNING 602 Fabric - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 679
,QoS CEE could not comply with FCoE scheduler policy for CEE Map . Probable Cause Indicates the DCE System Services Manager (SSM) was unable to translate CEE Map and FCoE configuration into an ETS scheduler policy implementable by the dataplane ASIC. Recommended Redefine - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 680
96 SSMD-1303 SSMD-1303 Message , [SSMD-1303], ,, INFO, , CEEMap priority group with weight is created with pfc . Probable Cause Indicates that priority Group has been created. Recommended No action is required. Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 681
96 SSMD-1307 SSMD-1307 Message , [SSMD-1307], ,, INFO, , access list is created. Probable Cause Indicates that Access List has been created. Recommended No action is required. Action Severity INFO SSMD-1308 Message , - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 682
96 SSMD-1311 SSMD-1311 Message , [SSMD-1311], ,, INFO, , ACL is removed from interface . Probable Cause Indicates that Access List has been removed from an interface. Recommended No action is required. Action Severity INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 683
power down the system during firmware upgrade. Allow the firmwareDownload command to continue without disruption. Run the firmwareDownloadStatus command command has completed successfully. Probable Cause Indicates the firmwareDownload command has completed successfully and switch firmware - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 684
CP reboots. Probable Cause Indicates the standby CP is rebooting with new firmware. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more information. Severity INFO 608 Fabric OS Message Reference 53 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 685
Probable Cause AUDIT, , [SULB-1009], AUDIT, INFO, FIRMWARE, , , , Firmwaredownload command failed. status: 0x, error: 0x. Indicates the firmwareDownload command failed. The additional status code and error code provide - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 686
secondary partition. Please use firmwareDownloadStatus and firmwareShow to see firmware status." "firmwareDownload has started on Standby CP. up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 687
firmwareDownloadStatus and 0x88 firmwareShow to see the firmware status." "Please use firmwareDownloadStatus and firmwareShow to see the firmware status." 0x89 "firmwareDownload command has completed successfully." 0x8a "The original firmware has been restored successfully." 0x8b "Remote CP - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 688
same version of firmware." 0xF "Upgrade is inconsistent. Run the bootEnv (root) command to correct the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 689
to upgrade to an intermediate version before downloading the desired version. If this error occurs in the middle of firmwareDownload, the firmware in the file server may be corrupted or there may be a temporary network issue. In this case, retry the firmwareDownload command. If the problem persists - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 690
or power off issues. Please reload firmware packages on the file server, then retry firmwareDownload. If the problem command for more information. In a director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 691
firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 692
and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1020 Message , [SULB-1020], AUDIT, ERROR, , New firmware failed to boot in slot . Probable Cause Indicates the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 693
unexpected disruption of the firmwareDownload command, for example, by powering off and on of the command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message , [SULB-1024], AUDIT, WARNING, , Firmware - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 694
command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message Probable Cause , [SULB-1031], , AUDIT, WARNING, , The switch is relocating an internal firmware image. Indicates the switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 695
by the internal Ethernet issue or by persistent storage failure. Recommended Action Restart the switch. This will cause the internal image to be relocated again. Use the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 696
it will continue without updating the co-CPU firmware. Recommended After firmwaredownload completes, reboot the CP manually to bring up the co-CPU and run the Action firmwareDownload command again. If the problem persists, contact the service provider. Severity WARNING 620 Fabric OS Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 697
Recommended Action Run the firmwareShow command to verify the firmware versions. Run the firmwareDownload command again if the firmware is not updated. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider. Severity WARNING Fabric - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 698
97 SULB-1040 622 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 699
as inconsistent during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR Fabric OS Message Reference 623 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 700
fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload Action command. Severity WARNING SWCH-1007 Message Probable Cause , [SWCH-1007], ,, WARNING, , Switch port disabled due to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 701
blade is enabled with the port configuration that does not support port swap. Recommended Action Replace the blade with ports that support port swap. Then swap the ports back to the ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 702
standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload command. Severity WARNING SWCH-1012 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 703
problem or due to file corruption. Recommended Action Restart or power cycle the switch If the message persists, run the firmwareDownload command to update the firmware a supported configuration. Remove the WWN-PID binding and re-enable the port and then run the wwnaddress --unbind wwn command. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 704
re-enable the port and then run the wwnaddress --unbind wwn command or the portaddress --unbind slot/port command. support dynamic area on default switch. Recommended Load a firmware version on the standby CP that supports dynamic area on default switch, using the Action firmwareDownload command - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 705
power cycle. Before restarting the chassis, record the firmware version on the switch or control processor (CP) and run the haDump command. If this is a dual-CP switch, is not supported by CP Blade with ID - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 706
Brocade 24000 and 48000. Recommended Action As indicated in the message, run the chassisConfig command to change to one that is valid on this platform running this firmware Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover Action command to recover the system - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 707
memory. Recommended Action Run the memShow command to view the switch memory usage. Restart or power cycle the switch. Run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 708
100 SYSM-1004 SYSM-1004 Message , [SYSM-1004], ,, ERROR, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates there was a failure to read configuration data from the WWN card. Recommended Verify that the world - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 709
TAPE System Messages Chapter 101 TAPE-1001 Message , [TAPE-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 710
101 TAPE-1001 634 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 711
, WATCHDOG EXPIRED, MANUAL, TRIGGER)>) Probable Cause Indicates that trace dump files have been generated on the switch or the indicated slot command. Recommended Run the supportFtp command to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 712
Run the supportFtp command to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. Severity to the FTP host has succeeded. This feature is enabled by the supportFtp -t command. Recommended No action is required. Action Severity INFO - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 713
to the Brocade 24000, and 48000. Recommended Action This message is often transitory. Wait for a few minutes and retry the command. If the message persists, run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 714
the main system and the indicated slot is unavailable. Recommended Make sure the blade is enabled and retry the command. If the blade is already enabled, run the Action supportSave command and contact your switch service provider. Severity WARNING 638 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 715
if the user name or password is incorrect. Recommended Action This message indicates a typing error by the user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of a failed login - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 716
switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload command. This message is not generated for a configUpload command is required. Run the trackChangesSet 1 command to enable the track changes feature. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 717
switch was IP network connection issues to the external clock server or if the fabric is configured for external time synchronization but the principal or primary FCS does not support the feature. If the message does not recur, it should be ignored. Recommended Action Run the tsClockServer command - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 718
Service exiting Probable Cause: Initialization error, Time Server exits. • Synchronizing time of day clock Probable Cause: Usually logged during temporary operational issues from the principal or primary fabric configuration server (FCS) switch. Another clock server in the list of clock servers - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 719
the switch detected an inconsistency in the routing database between the routing protocol and the hardware configuration. The first port number displayed is what the hardware has configured and the second port number displayed is what the protocol is using. Recommended Run the switchDisable command - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 720
>, [UCST-1025], ,, INFO, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 721
because the enabled TI zone is not compatible with the fabric configuration. Probable Cause Indicates the specified switch is unreachable because of the TI zone and the fabric configuration incompatibility. Recommended Clear all TI zones and refer to the TI zone user manual for instructions on how - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 722
106 UPTH-1002 646 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 723
WEBD System Messages Chapter 107 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured but could not be started. Probable Cause Indicates the SSL certificate file is either invalid or absent. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 724
will be restarted due to change of IP Address. Probable Cause Indicates the IP address of the switch changed and the HTTP server is restarted. where the built-in recovery process has failed to restore HTTP services. The problem often results from invalid configuration of SSL certificates, but there - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 725
the FCP exchange has timed out. Recommended If there was an unexpected job failure associated with this event, contact your customer support for Action assistance. Severity ERROR XTUN-1003 Message , [XTUN-1003], ,, ERROR, , Message Transmission failed - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 726
unexpected job failure associated with this event, contact your customer support for Action assistance. Severity ERROR XTUN-1998 Message , Buffer Number> has been cleared. Probable Cause Indicates that a CLI command caused the trace buffer to be put back into the FTRACE free pool - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 727
, [XTUN-2004], ,, INFO, , FCIP Tunnel Pri QoS UP. Indicates that the specified quality of service for this tunnel is up. This applies to the data classes only. When the f-class comes online, the tunnel itself is marked as up - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 728
-number>,, INFO, , FCIP Tunnel Pri QoS DOWN . Probable Cause Indicates that the specified quality of service has gone down. This applies to the data classes only. If the f-class goes down, the tunnel itself is marked as down. Recommended If the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 729
ZEUS System Messages Chapter 109 ZEUS-1001 Message , [ZEUS-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 730
109 ZEUS-1001 654 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 731
of the related modules (zoned, nsd, rcsd). If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command to save these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 655 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 732
110 ZOLB-1001 656 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 733
during port login (PLOGI) trap processing. This messages usually indicates problems when command and contact your switch service provider. Severity WARNING ZONE-1003 Message , [ZONE-1003], ,, WARNING, , zone() contains (, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 734
using one method or the other to define all objects in the zoning database. If the devices on the port are defined by a mixture of port IDs and WWNs, the zone enforcement is session based. If the S_ID list of the hardware-enforced zoning overflows (over the S_ID limit), the hardware zone enforcement - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 735
problem. • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single port group on the switch in a given zone object. This message occurs only when enabling a zone configuration. Recommended Check the members of the zone and - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 736
is enabled on the switch, it will not be supported. Recommended Edit the zone database to remove the QuickLoop zoning definition in the effective configuration. Action Severity WARNING ZONE-1014 Message , [ZONE-1014], ,, ERROR, , Missing required license - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 737
based hard zoning (value = 3) • FA zone (value = 5) QuickLoop zones are not supported in Fabric OS v4.x and above. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 738
operation. This usually occurs if the switch on the other side of the port is busy. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE-1024 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 739
for an unknown reason. • User Command: A user aborted the current zoning transaction. • Switch Shutting Down: The switch is currently shutting down. Recommended switches in your fabric. Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 740
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING ZONE-1030 Message < Switch is in interop mode. (switch, port) members not supported. Probable Cause Indicates the switch is set to interop mode using the interopMode command - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 741
Indicates the Fabric OS cannot create the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR Fabric OS Message Reference 665 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 742
the Fabric OS cannot examine the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR ZONE-1038 Message , [ZONE-1038], - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 743
WARNING, , Unstable link detected during merge at port (). Probable Cause Indicates a possible unstable link or faulty cable number>,, INFO, , The Default Zone access mode is set to No Access. Probable Cause Indicates the Default Zone access mode is set to No - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 744
>,, INFO, , Switch domain () does not support defined database. Probable Cause Indicates a remote Brocade switch is running a downlevel version of Fabric OS that does not support the defined database. Recommended It is recommended to upgrade all switches to the same release - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 745
AD-DefZone conflict. Recommended Check and resolve the default zone mismatch issue. Action Severity ERROR ZONE-1050 Message , Default Zone state is set to enabled. Probable Cause Indicates the Interop Default Zone attribute state is enabled. Recommended Verify if the Interop Default - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 746
Recommended Remove frame redirection zones or set the defzone command to noaccess mode. Action Severity WARNING ZONE-1055 Message , [ZONE-1055], ,, WARNING, , McDATA default zone enabled with Frame Redirection zones. Probable Cause Indicates that frame - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 747
TI Zone has domain running pre FOS6.4.0 firmware. TI member (Domain , Index ) is not supported. Probable Cause Indicates that an unsupported port index(> 511) is present in the TI zone path - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 748
111 ZONE-1057 672 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 749
699 •AUDIT FICU System Messages 701 •AUDIT FW System Messages 703 •AUDIT HTTP System Messages 705 •AUDIT IPAD System Messages 707 •AUDIT PORT System Messages 709 •AUDIT SEC System Messages 711 •AUDIT SNMP System Messages 729 •AUDIT SPM System Messages 731 •AUDIT SULB System Messages 739 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 750
674 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 751
. Action Severity INFO AG-1036 Message AUDIT, , [AG-1036], ,, WARNING, ,Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Fabric OS Message Reference 675 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 752
Area has been acquired, then check cabling: all trunked ports should be in same ASIC Port Group . Probable Cause Indicates that the cabling is incorrect. Recommended Action If the switchshow command on the connected fabric switch port displays 'Persistently disabled: Area has been acquired', then - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 753
affected by this condition. Probable Cause For an F_Port, it indicates that the attached device is slow in responding to frames going out of this port. This latency may be inherent in the device or due to heavy workload on the device. For an E_Port, it indicates a downstream primary bottleneck - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 754
WARNING, , Severe latency bottleneck detected at Slot port . Probable Cause Indicates a credit loss. Recommended Contact your vendor's customer support for assistance. Action Severity WARNING 678 Fabric OS Message Reference 53-1001767 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 755
, , Certificate not present in this switch in port . Probable Cause Indicates that the public key command. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 756
secret database operation has been updated using the secAuthSecret command. Recommended No action is required. Action Severity INFO , Status: failed, Info: Neighboring switch has a conflicting authentication policy; Port disabled. 680 Fabric OS Message Reference 53 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 757
authentication. Recommended Action If the light on the specified port is off, correct the switch policy configuration on either of the switches using the authUtil command, and then enable the port on the neighboring switch using the portEnable command. If the E_Port formed no action is required - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 758
to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-3008 Message AUDIT, , Probable Cause Indicates that the specified port has been disabled, because the connecting switch/device failed to authenticate. The - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 759
AUDIT BLS System Messages Chapter 115 BLS-1002 Message , [BLS-1002], ,, INFO, , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec or IKE policy was added and the configuration file was updated. Recommended No action is required. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 760
115 BLS-1003 684 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 761
AUDIT CNM System Messages Chapter 116 CNM-3001 Message AUDIT, , [CNM-3001], INFO, , , , , Event: cryptocfg Status: success, Info: encryption group \\ created. Probable Cause Indicates an encryption group was created. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 762
116 CNM-3004 CNM-3004 Message AUDIT, , [CNM-3004], INFO, , , , , Event: cryptocfg Status: success, Info: Membernode \\ ejected from encryption group. Probable Cause Indicates a membernode was ejected from an encryption group. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 763
CNM-3008 116 Severity INFO CNM-3008 Message AUDIT, , [CNM-3008], INFO, , , , , Event: cryptocfg Status: success, Info: Routing mode of EE in slot set to . Probable Cause Indicates that the encryption engine (EE) routing - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 764
116 CNM-3012 Recommended No action is required. Action Severity INFO CNM-3012 Message AUDIT, , [CNM-3012], ,, INFO, , Deleteing an EG with luns setup for encryption can lead to luns being disabled if Encryption Group name is not preserved (). - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 765
the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description. Recommended No action is required. error log, correct the error and rerun the configDownload command. Action Fabric OS Message Reference 689 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 766
was unsuccessful because there are one or more parameters that require the switch to be disabled. Recommended Disable the switch using the switchDisable command and download the configuration. Action Severity WARNING CONF-1042 Message , [CONF-1042], ,, INFO, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 767
AUDIT CVLM System Messages Chapter 118 CVLM-3001 Message AUDIT, , [CVLM-3001], INFO, , , , , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates that the failback mode was set. Recommended No - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 768
118 CVLM-3004 CVLM-3004 Message AUDIT, , [CVLM-3004], INFO, , , , , Event: cryptocfg Status: success, Info: Cluster member added to HA cluster . Probable Cause Indicates a HA cluster member was added to an HA cluster. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 769
-3009], INFO, , , , , Event: cryptocfg Status: success, Info: Manual failback from EE / to EE /. Probable Cause Indicates a manual failback was performed to an encryption engine. Recommended No action is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 770
118 CVLM-3012 Recommended No action is required. Action Severity INFO CVLM-3012 Message AUDIT, , [CVLM-3012], INFO, , , , , Event: cryptocfg Status: success, Info: Initiator \\ removed from crypto target container \< - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 771
, Info: Lun , attached through Initiator \\, in crypto target container \\ enabled. Probable Cause Indicates a LUN in a cryptotarget container was enabled. Recommended No action is required. Action Severity INFO CVLM-3017 Message AUDIT, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 772
CVLM-3020 Message AUDIT, , [CVLM-3020], INFO, , , , , Event: cryptocfg Status: success, Info: Manual rekey of LUN attached through Initiator \\ in crypto tgt container \\. Probable Cause Indicates - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 773
118 CVLM-3022 CVLM-3022 Message AUDIT, , [CVLM-3022], INFO, , , , , Event: cryptocfg Status: success, Info: Resume rekey of LUN attached through Initiator \\ in crypto tgt container \\. Probable - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 774
, LUN ). Probable Cause Indicates that the decommission operation has failed for the device. Recommended Reissue the decommission command. Action Severity INFO CVLM-3027 Message AUDIT, , [CVLM-3027], ,, INFO, , Event: cryptocfg Status - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 775
AUDIT FCIP System Messages Chapter 119 FCIP-1002 Message AUDIT, , [FCIP-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended No action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 776
119 FCIP-1003 700 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 777
mode has been enabled. Probable Cause Indicates that the FICON Management server mode has been enabled. Recommended No switch. Recommended No action is required. Action Severity INFO FICU-1020 Message Probable Cause AUDIT, , [FICU-1020], ,, INFO, , Port - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 778
120 FICU-1021 Recommended No action is required. Action Severity INFO FICU-1021 Message AUDIT, , [FICU-1021], ,, INFO, , Port Addrs (%s) have been UnBlocked by %s. Probable Cause Indicates the Fibre Connectivity (FICON) Management server has unblocked - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 779
, , , , Event: , Status: success, Info: Probable Cause Indicates that Port Fencing was enabled/disabled successfully. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 703 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 780
121 FW-3001 704 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 781
AUDIT HTTP System Messages Chapter 122 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 782
122 HTTP-1003 706 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 783
[IPAD-1002], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 707 53 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 784
123 IPAD-1002 708 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 785
action is required. Action Severity INFO PORT-1008 Message AUDIT, , [PORT-1008], INFO, CFG, , , , GigE Port (ID: ) has been enabled. Probable Cause Indicates a GigE port has been enabled. Recommended No action is required. Action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 786
124 PORT-1009 Probable Cause Indicates a GigE port has been disabled. Recommended No action is required. Action Severity INFO 710 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 787
expired. Recommended Get a new license for this feature. Action Severity WARNING SEC-3001 Message AUDIT, , [SEC-3001], INFO, SECURITY, , , , Event: , Status: success, Info: Security mode on the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 788
server (FCS) failover. • A security policy has been activated. • A security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 789
SEC-3005 125 Severity INFO SEC-3005 Message AUDIT, , [SEC-3005], INFO, SECURITY, , , , Event: , Status: success, Info: Added members to policy . Probable Cause Indicates new members have been added to - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 790
125 SEC-3008 SEC-3008 Message AUDIT, , [SEC-3008], INFO, SECURITY, , , , Event: , Status: success, Info: FCS member moved from position to . Probable Cause Indicates the fabric configuration - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 791
-location>, , Event: , Status: success, Info: Temp Passwd on domain [] for account []. Probable Name> for AAA services. Probable Cause Indicates a user has changed the remote authentication dial-in user service (RADIUS) configuration. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 792
name> to position . Probable Cause Indicates a user has changed the position of the remote authentication dial-in user service (RADIUS) server. Recommended Action Verify the RADIUS server position was intentionally changed. If the RADIUS server position was intentionally changed - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 793
: Passwdcfg parameters set to default values. Probable Cause Indicates the passwdCfg parameters are set to default values. Recommended Action Verify the attempt via . Probable Cause Indicates a successful login occurred. An IP address is displayed when the login - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 794
Cause Indicates the maximum number of failed password entries has been exceeded. The account has been locked as a result. Recommended The account may automatically unlock after the lockout duration has expired or an administrator Action may manually unlock the account. Severity INFO SEC-3024 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 795
, , , , Event: , Status: success, Info: User account [] added. Role: [], Password [], Home AD [], AD list []. Probable Cause Indicates a new user account was created - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 796
125 SEC-3029 Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3029 Message AUDIT, , [SEC - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 797
, , Event: , Status: success, Info: Switch is configured to database. Probable Cause ipfilter, Status: success, Info: IP filter policy(ies) saved. Indicates the specified IP filter policies have been saved. Fabric OS - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 798
3038], INFO, SECURITY, , , , Event: ipfilter, Status: failed, Info: Failed to activate . Probable Cause Indicates the specified IP filter policy failed to activate. Recommended Action Verify the security event was planned. If the security - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 799
. Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Take Action appropriate action as defined - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 800
Verify the user has the required permission to execute this command. Action Severity INFO SEC-3048 Message AUDIT, , [SEC-3048], INFO, SECURITY, , , FIPS mode has been enabled in the system using force option. Probable Cause Indicates the - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 801
INFO SEC-3051 Message AUDIT, , [SEC-3051], INFO, SECURITY, , , , The license key is . Probable Cause Indicates that a license key is added or removed. Recommended No action is required. Action Severity INFO SEC-3061 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 802
are downloaded. Recommended No action is required. Action Severity INFO SEC-4001 Message , [SEC-4001], , AUDIT, INFO, , Client logged in . 726 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 803
Probable Cause Indicates the client has logged in. Recommended No action is required. Action Severity INFO SEC-4001 125 Fabric OS Message Reference 727 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 804
125 SEC-4001 728 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 805
incorrect and the SNMP service will not work correctly. Recommended Reset the SNMP configuration to default. Action Severity ERROR SNMP and new values for that parameter. Recommended Execute the snmpConfig --show command to display the new configuration. Action Severity INFO SNMP-1006 Message - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 806
126 SNMP-1006 730 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 807
. Action Severity INFO SPM-3004 Message AUDIT, , [SPM-3004], INFO, , ,,Event: cryptocfg Status: success, Info: EE in slot enabled. Fabric OS Message Reference 731 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 808
127 SPM-3005 Probable Cause Indicates an encryption engine was enabled. Recommended No action is required. Action Severity INFO SPM-3005 Message AUDIT, , [SPM-3005], INFO, , ,,Event: cryptocfg Status: success, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 809
, , [SPM-3008], INFO, , ,,Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Probable Cause Indicates a DH challenge was generated for a key vault. Recommended No action is required. Action Severity INFO SPM - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 810
-location>,,Event: cryptocfg Status: success, Info: key vault registered. Certificate label: \"\" Certificate file: \"\" IP address: . Probable Cause Indicates a key vault was registered. Recommended No action is required. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 811
SPM-3016 127 Severity INFO SPM-3016 Message AUDIT, , [SPM-3016], INFO, , ,,Event: cryptocfg Status: success, Info: Master key generated. Probable Cause Indicates a master key was generated. Recommended No action is required. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 812
AUDIT, , [SPM-3023], INFO, , ,,Event: cryptocfg Status: success, Info: System card . Indicates use of the system card was enabled or disabled. 736 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 813
SPM-3024 127 Recommended No action is required. Action Severity INFO SPM-3024 Message AUDIT, , [SPM-3024], INFO, , ,,Event: cryptocfg Status: success, Info: Quorum size set to . Probable Cause Indicates the quorum size was set. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 814
127 SPM-3028 Probable Cause Indicates a recovery card was registered. Recommended No action is required. Action Severity INFO SPM-3028 Message AUDIT, , [SPM-3028], ,, INFO, , Event: SPM-EE state changed, Info: EE State: . Probable Cause - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 815
. Recommended Action No action is required. Allow the firmwareDownload command to continue without disruption. Do not fail over or power down the system during firmware upgrade. Run the firmwareDownloadStatus command for more information. Severity WARNING SULB-1002 Message AUDIT, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 816
Message Probable Cause AUDIT, , [SULB-1009], INFO, FIRMWARE, , , , Firmwaredownload command failed. status: 0x, error: 0x. Indicates the firmwareDownload command failed. The additional status code and error code provide - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 817
secondary partition. Please use firmwareDownloadStatus and firmwareShow to see firmware status." "firmwareDownload has started on Standby CP. up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 818
firmwareDownloadStatus and 0x88 firmwareShow to see the firmware status." "Please use firmwareDownloadStatus and firmwareShow to see the firmware status." 0x89 "firmwareDownload command has completed successfully." 0x8a "The original firmware has been restored successfully." 0x8b "Remote CP - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 819
same version of firmware." 0xF "Upgrade is inconsistent. Run the bootEnv (root) command to correct the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 820
to upgrade to an intermediate version before downloading the desired version. If this error occurs in the middle of firmwareDownload, the firmware in the file server may be corrupted or there may be a temporary network issue. In this case, retry the firmwareDownload command. If the problem persists - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 821
or power off issues. Please reload firmware packages on the file server, then retry firmwareDownload. If the problem command for more information. In a director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 822
firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 823
the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message AUDIT, , [SULB-1021], WARNING, FIRMWARE, , , , Firmware is being downloaded to the blade in slot - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 824
version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message AUDIT - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 825
The firmwareDownload command will continue after the switch has rebooted. Run the firmwareDownloadStatus command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message AUDIT, , [SULB-1032], WARNING, FIRMWARE, - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 826
internal image to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, HCL failed. Reboot the switch manually using the reboot command. However, it will disrupt the FC traffic - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 827
Recommended Action Run the firmwareShow command to verify the firmware versions. Run the firmwareDownload command again if the firmware is not updated. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider. Severity WARNING Fabric - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 828
128 SULB-1040 752 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 829
-1012], INFO, CFG, , , , Trunk Area () has been enabled for one or more ports. Probable Cause Indicates a Trunk Area has been enabled for one or more ports and the config file has been updated. Recommended No action is required. Action Severity - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 830
129 SWCH-1014 754 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 831
[UCST-1021], INFO, CFG, , , , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 832
INFO, CFG, , , , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 833
Severity INFO 130 UCST-1027 Fabric OS Message Reference 757 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 834
130 UCST-1027 758 Fabric OS Message Reference 53-1001767-01 - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 835
AUDIT ZONE System Messages Chapter 131 ZONE-3001 Message AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \" - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 836
131 ZONE-3004 The zone object type can be "alias", "zone member", "zone" or "zone configuration". The string "..." appears at the end of the zone object member list if the list was truncated in the message. Recommended Verify the event was planned. If the event was planned, no action is required. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 837
-details>, , , Event: , Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates the specified zone configuration has been enabled. Recommended Verify the event was planned. If the event was planned, no action is - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 838
131 ZONE-3011 Severity INFO ZONE-3011 Message AUDIT, , [ZONE-3011], INFO, ZONE, , , , Event: , Status: success, Info: Zone object \"\" expunged. Probable Cause Indicates the specified zone object has been expunged - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 839
131 ZONE-3015 An AD object set type is "AD member". The string "..." appears at the end of the AD object member list if the list was truncated in the message. Recommended Verify the event was planned. If the event was planned, no action is required. If the event was not Action planned, take - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 840
131 ZONE-3018 ZONE-3018 Message AUDIT, , [ZONE-3018], INFO, FABRIC, , , , Event: , Status: success, Info: has been deactivated. Probable Cause Indicates the specified admin domain (AD) object has been deactivated. - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 841
. Severity INFO ZONE-3025 Message Probable Cause Recommended Action AUDIT, , [ZONE-3025], INFO, FABRIC, , , , Command: Info: executed. In AD . Indicates the admin domain ad --exec operation was executed in the specified AD - HP 8/40 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 842
131 ZONE-3025 Severity INFO 766 Fabric OS Message Reference 53-1001767-01
53-1001767-01
30 March 2010
®
Fabric OS
Message Reference
Supporting Fabric OS v6.4.0