HP 8/40 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 703
SWCH-1015, Recommended, Action, Severity, Message, Probable Cause, firmwareDownload
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 703 highlights
98 SWCH-1015 Recommended No action is required. Action Severity INFO SWCH-1015 Message , [SWCH-1015], ,, WARNING, , . Probable Cause Indicates that an internal problem has been detected by the software. This is usually an internal Fabric OS problem or due to file corruption. Recommended Action Restart or power cycle the switch If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING SWCH-1016 Message , [SWCH-1016], ,, INFO, , Device fdiscs to port . Static persistent PID set and area requested not assigned to the device. Reject FDISC. Probable Cause Indicates static persistent PID is set and the area requested is not assigned to the device. Recommended Action This is a NPIV device and static peristent PID is set on it, we are not able to assign the area requested. Remove the static binding to have the device come up with a different area and run the wwnaddress --unbind wwn command. Severity INFO SWCH-1017 Message , [SWCH-1017], ,, INFO, , Device tries to flogi to port , reject FLOGI as persistent PID is set on the Loop device. Probable Cause Indicates persistent PID is set and static Persistent PID is not supported on the Loop device. Recommended Action This is a LOOP device and peristent PID is set on it. This is not a supported configuration. Remove the WWN-PID binding and re-enable the port and then run the wwnaddress --unbind wwn command. Severity INFO Fabric OS Message Reference 627 53-1001767-01