HP 8/40 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 282
Fcoe-1022, Fcoe-1023, Fcoe-1024, Fcoe-1025
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 282 highlights
31 FCOE-1022 Recommended No action is required. Action Severity INFO FCOE-1022 Message , [FCOE-1022], ,, WARNING, , Max FCoE device login limit reached. Probable Cause Indicates that the switch has reached its maximum allowed FCoE device limit. Recommended Do not add any more FCoE devices to the switch. Action Severity WARNING FCOE-1023 Message , [FCOE-1023], ,, WARNING, , Too many logins on FCoE controller, max allowed = . Probable Cause Indicates that the controller has reached its maximum allowed FCoE login limit. Recommended No action is required. Action Severity WARNING FCOE-1024 Message , [FCOE-1024], ,, WARNING, , FDISC received from Enode without prior FLOGI. Probable Cause Indicates no root Nport has logged in. Recommended No action is required. Action Severity WARNING FCOE-1025 Message Probable Cause , [FCOE-1025], ,, WARNING, , FCOE logout received on FIP VN port. Indicates a pre-FIP logout for a device that has logged in using FIP protocol. 206 Fabric OS Message Reference 53-1001767-01