HP 8/40 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 205
Cvlc-1022, Cvlc-1023, Cvlc-1024, Cvlc-1025
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 205 highlights
19 CVLC-1022 CVLC-1022 Message , [CVLC-1022], ,, INFO, , User provided key ID is ignored while data state is clear text.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the key ID provided is ignored because the data state is clear text. Recommended No action is required. Action Severity INFO CVLC-1023 Message , [CVLC-1023], ,, INFO, , Rebalance recommended on EE: . Probable Cause Indicates that due to container configuration changes, weights are not balanced on OB1s. Recommended Run "cryptocfg --rebalance" to increase system performance. Action Severity INFO CVLC-1024 Message , [CVLC-1024], ,, INFO, , Device Decommission operation .\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the device decommission process has either succeeded or failed. Recommended No action is required. Action Severity INFO CVLC-1025 Message , [CVLC-1025], ,, ERROR, , Secondary Metadata exists for encrypted LUN not configured with -newLUN option .\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the secondary metadata exists on the LUN that is not configured with --newLUN option. Recommended Use th ecryptocfg command to remove and add the LUN with --newLUN option. Action Fabric OS Message Reference 129 53-1001767-01