HP 8/40 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 445
HIL System Messages, HIL-1101
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 445 highlights
Chapter HIL System Messages 45 HIL-1101 Message , [HIL-1101], ,, ERROR, , Slot faulted, () is above threshold. Probable Cause Indicates that the blade voltage is above threshold. Recommended Replace the faulty blade or switch (for nonbladed switches). Action Severity ERROR HIL-1102 Message , [HIL-1102], ,, ERROR, , Slot faulted, () is below threshold. Probable Cause Indicates that the blade voltage is below threshold. Recommended Replace the faulty blade or switch (for nonbladed switches). Action Severity ERROR HIL-1103 Message , [HIL-1103], ,, ERROR, , Blower faulted, () is above threshold. Probable Cause Indicates that the fan voltage is above threshold. Recommended Action Run the psShow command to verify the power supply status. Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. Severity ERROR Fabric OS Message Reference 369 53-1001767-01