HP DL580 ProLiant DL580 Generation 4 Maintenance and Service Guide - Page 43

Removing the PCI-X Hot Plug mezzanine option, Removing the PCI Express mezzanine option

Page 43 highlights

To replace the component, reverse the removal procedure. Removing the PCI-X Hot Plug mezzanine option 1. Power down the server (on page 29). 2. Extend or remove the server from the rack ("Extending the server from the rack" on page 27, "Remove the server from the rack" on page 29). 3. Remove the access panel ("Removing the access panel" on page 29). 4. Remove the expansion boards from slots 1 and 2. 5. Remove the expansion boards from slots 3 and 4, if installed, to gain access to the mezzanine board. 6. Remove the PCI-X Hot Plug basket ("Removing the PCI-X Hot Plug basket" on page 41). 7. Disconnect the cable from the PCI-X Hot Plug mezzanine board ("PCI-X Hot Plug mezzanine cabling" on page 95). 8. Loosen the thumbscrews, and lift the mezzanine board from the server. CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all expansion slots have either an expansion slot cover or an expansion board installed. To replace the component, reverse the removal procedure. Removing the PCI Express mezzanine option 1. Power down the server (on page 29). 2. Extend or remove the server from the rack ("Extending the server from the rack" on page 27, "Remove the server from the rack" on page 29). 3. Remove the access panel ("Removing the access panel" on page 29). 4. Remove the expansion boards from slots 1 and 2. 5. Remove the expansion boards from slots 3 and 4, if installed, to gain access to the mezzanine board. Removal and replacement procedures 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109

Removal and replacement procedures
43
To replace the component, reverse the removal procedure.
Removing the PCI-X Hot Plug mezzanine option
1.
Power down the server (on page
29
).
2.
Extend or remove the server from the rack ("
Extending the server from the rack
" on page
27
,
"
Remove the server from the rack
" on page
29
).
3.
Remove the access panel ("
Removing the access panel
" on page
29
).
4.
Remove the expansion boards from slots 1 and 2.
5.
Remove the expansion boards from slots 3 and 4, if installed, to gain access to the mezzanine
board.
6.
Remove the PCI-X Hot Plug basket ("
Removing the PCI-X Hot Plug basket
" on page
41
).
7.
Disconnect the cable from the PCI-X Hot Plug mezzanine board ("
PCI-X Hot Plug mezzanine cabling
"
on page
95
).
8.
Loosen the thumbscrews, and lift the mezzanine board from the server.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all expansion slots have either an expansion slot cover or an expansion board installed.
To replace the component, reverse the removal procedure.
Removing the PCI Express mezzanine option
1.
Power down the server (on page
29
).
2.
Extend or remove the server from the rack ("
Extending the server from the rack
" on page
27
,
"
Remove the server from the rack
" on page
29
).
3.
Remove the access panel ("
Removing the access panel
" on page
29
).
4.
Remove the expansion boards from slots 1 and 2.
5.
Remove the expansion boards from slots 3 and 4, if installed, to gain access to the mezzanine
board.