Installing the Plenum (if required) See Before You Begin - Important Information about the Plenum, page 4 to determine if you need to install the plenum before inserting the device in the rack. To install the plenum: 1. Place the device (with inner rails attached) on a flat surface, see Figure 8. 2. Obtain the plenum and four 8-32 x .312 Phillips Pan-head SEMs screws from the accessory kit. These are the same screws used to attach the inner rails in step 5 of the previous section. 3. For each inner rail (Left and Right) use one screw hole marked 8 and one screw hole marked 16 to attach the plenum. Caution: Verify that the open end of the plenum faces the rear of the device. For example, when installed properly you should see the plenum's air vent holes on one side, and the front panel of the device on the other. The components shown in Figure 8 include the plenum (1), a switch (2), and the screws that attach the rails to the plenum (3). 1 2 IOIOI ! 3 mMAoaTuxTnimtEinugmNtoTscbIrOeew5Nmle:mngothr 1fo3r/6ra4cikn. Figure 8: Attaching the Plenum to a 4/8 or 4/16 SAN Switch SAN Switch rack mount kit installation instructions 25052a 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

17
SAN Switch rack mount kit installation instructions
Installing the Plenum (if required)
See
Before You Begin - Important Information about the Plenum
, page 4 to
determine if you need to install the plenum before inserting the device in the
rack.
To install the plenum:
1.
Place the device (with inner rails attached) on a flat surface, see
Figure 8
.
2.
Obtain the plenum and four
8-32 x .312 Phillips Pan-head SEMs
screws from the accessory kit. These are the same screws used to
attach the inner rails in
step 5
of the previous section.
3.
For each inner rail (
Left
and
Right
) use one screw hole marked
8
and
one screw hole marked
16
to attach the plenum.
Caution:
Verify that the open end of the plenum faces the rear of the
device. For example, when installed properly you should see the plenum’s
air vent holes on one side, and the front panel of the device on the other.
The components shown in
Figure 8
include the plenum (1), a switch (2),
and the screws that attach the rails to the plenum (3).
Figure 8:
Attaching the Plenum to a 4/8 or 4/16 SAN Switch
IOIOI
25052a
1
2
ATTENTION:
Maximum screw length for rack
mounting to be 5mm or 13/64 in.
3