HP StorageWorks 2/16V HP StorageWorks SAN Switch Rack Mount Kit Installation I - Page 17
Installing the Plenum (if required), Attaching the Plenum to a 4/8 or 4/16 SAN Switch
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Installing the Plenum (if required) See Before You Begin - Important Information about the Plenum, page 4 to determine if you need to install the plenum before inserting the device in the rack. To install the plenum: 1. Place the device (with inner rails attached) on a flat surface, see Figure 8. 2. Obtain the plenum and four 8-32 x .312 Phillips Pan-head SEMs screws from the accessory kit. These are the same screws used to attach the inner rails in step 5 of the previous section. 3. For each inner rail (Left and Right) use one screw hole marked 8 and one screw hole marked 16 to attach the plenum. Caution: Verify that the open end of the plenum faces the rear of the device. For example, when installed properly you should see the plenum's air vent holes on one side, and the front panel of the device on the other. The components shown in Figure 8 include the plenum (1), a switch (2), and the screws that attach the rails to the plenum (3). 1 2 IOIOI ! 3 mMAoaTuxTnimtEinugmNtoTscbIrOeew5Nmle:mngothr 1fo3r/6ra4cikn. Figure 8: Attaching the Plenum to a 4/8 or 4/16 SAN Switch SAN Switch rack mount kit installation instructions 25052a 17