HP StorageWorks 2/32 SAN switch 2/32, version 4.0.2b release notes - Page 10

Fabric OS Command Changes, portcfglongdistance Command Summary, Enhancement, linkinitmode Operand - san switch manuals

Page 10 highlights

SAN Switch 2/32 Firmware Version 4.0.2b Updates Fabric OS Command Changes The following lists new or modified commands added to the Fabric OS Version 4.0.2b: • killtelnet command • loopporttest command • portcfgdelayflogi command • supportshow command • portcfglongdistance command • portcfgshow command • ifmodeset command NOTE: For more information about these commands, refer to the hp StorageWorks Fabric OS Version 3.0.x/4.0.x Reference Manual. portcfglongdistance Command Summary Extended links in the same SAN are either 1Gb or 2Gb, but not both. If you have 1 Gb extended links in the the SAN you can not add a 2Gb Extended Link to the same SAN. Enhancement A new parameter was added to this command. The new syntax is as follows: portCfgLongDistance [slot/]port[, distance_level][, linkinitmode] linkinitmode Operand The linlinitmode operand applies to long distance setup only. It does not affect a normal link. It is added to ensure the long distance link initialization sequence. It is not required for long distance, but may be useful when initiating L1 and L2 links. linkinitmode Usage Specify 1 to activate a long distance link initialization sequence. Specify 0 to deactivate this mode. The default value is 0 (disabled). This operand is optional. The following example is for a 100km link on a port in a V4.0 switch with long distance link initialization protocol enabled: switch:admin> portCfgLongDistance 2/3 L2 1 done. 10 SAN switch 2/32, version 4.0.2b release notes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

SAN Switch 2/32 Firmware Version 4.0.2b Updates
10
SAN switch 2/32, version 4.0.2b release notes
Fabric OS Command Changes
The following lists new or modified commands added to the Fabric OS Version 4.0.2b:
killtelnet
command
loopporttest
command
portcfgdelayflogi
command
supportshow
command
portcfglongdistance
command
portcfgshow
command
ifmodeset
command
NOTE:
For more information about these commands, refer to the
hp StorageWorks Fabric OS
Version 3.0.x/4.0.x Reference Manual
.
portcfglongdistance
Command Summary
Extended links in the same SAN are either 1Gb or 2Gb, but not both. If you have 1 Gb
extended links in the the SAN you can not add a 2Gb Extended Link to the same SAN.
Enhancement
A new parameter was added to this command. The new syntax is as follows:
portCfgLongDistance [slot/]port[, distance_level][, linkinitmode]
linkinitmode Operand
The linlinitmode operand applies to long distance setup only. It does not affect a
normal link. It is added to ensure the long distance link initialization sequence.
It is not required for long distance, but may be useful when initiating L1 and L2 links.
linkinitmode Usage
Specify 1 to activate a long distance link initialization sequence. Specify 0 to
deactivate this mode. The default value is 0 (disabled). This operand is optional. The
following example is for a 100km link on a port in a V4.0 switch with long distance
link initialization protocol enabled:
switch:admin> portCfgLongDistance 2/3 L2 1
done.