HP StorageWorks 2/32 SAN switch 2/32, version 4.0.2b release notes - Page 6
SAN Switch 2/32 Hardware Updates
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
SAN Switch 2/32 Hardware Updates 6. Clear the switch of all zoning information by running the following set of commands: cfgdisable cfgclear cfgsave 7. Connect the switch to the fabric through an ISL cable. Once the switch is connected to the fabric, the zone configuration information for the fabric will automatically copy to the switch. 8. Clear the Management server Platform Database from the switch with the msPlClearDB command. SAN Switch 2/32 Hardware Updates The following section lists hardware updates for the SAN Switch 2/32. Important Information Regarding the HP System/e Rack Mounting Hardware HP highly recommends installing the switch in the optional System/e Rack using only the hardware supplied with the rack. For example, when installing the two inner rails on either side of the switch, you must use the six #8-32 x 5/16 Phillips pan-head screws, and #8 flat washers as specified in the hp StorageWorks SAN Switch 2/32 Installation Guide. The #8 flat washer shortens the #8-32 x 5/16 Phillips pan-head screw so that it does not interfere with the internal components of the switch. IMPORTANT: Using longer than recommended screws to install your switch into the HP System/e Rack Kit will result in physical damage to the switch motherboard. 6 SAN switch 2/32, version 4.0.2b release notes