HP StorageWorks 4000/6000/8000 .HP StorageWorks SAN Design Reference Guide, Pa - Page 138
the HP SAN Infrastructure website, Table 41 C-series Fibre Channel switches for SAN-OS
View all HP StorageWorks 4000/6000/8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
dating switch firmware, you can use two successive NX-OS/SAN-OS/FabricWare versions temporarily. Do not enable new switch features until the upgrade is complete. • Follow the fabric rules. (See "Fibre Channel switch fabric rules" on page 146.) For the latest information on supported C-series Fibre Channel switches and firmware versions, see the HP SAN Infrastructure website: http://h18006.www1.hp.com/storage/saninfrastructure.html Table 41 C-series Fibre Channel switches for SAN-OS Switch MDS 9506 Multilayer Director MDS 9509 Multilayer Director MDS 9513 Multilayer Director MDS 9222i Multiservice Fabric MDS 9124 Fabric MDS 9134 Fabric Firmware version SAN-OS 3.3(4a), 3.3(4), 3.3(3), 3.3(2), 3.3(1c), 3.3(1a), 3.2(3), 3.2(2c), 3.2(1a), 3.1(3a), 3.1(3), 3.1(2a) Maximum number of Fibre nl Channel ports 192 336 528 66 24 32 at 4 Gb/s 2 at 10 Gb/s MDS 9124e 12-Port Fabric Switch for HP c-Class BladeSystem MDS 9124e 24-Port Fabric Switch for HP c-Class BladeSystem 8 internal, 4 external 16 internal, 8 external NOTE: MDS 9509 requires Supervisor-2 Modules to use the maximum port count. 138 C-series switches and fabric rules