HP StorageWorks 4000/6000/8000 .HP StorageWorks SAN Design Reference Guide, Pa - Page 325
Table 154, To increase the maximum number of DR groups, you must increase the minimum available IP
View all HP StorageWorks 4000/6000/8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 325 highlights
gateway pairs. Table 154 lists the network requirements for long-distance gateways that work with EVA4400 and EVA4400 (embedded switch) XCS 09x. Table 154 Network requirements for long-distance IP gateways with XCS 09x Specification IP bandwidth1 Description • Must be dedicated to the Continuous Access storage replication function. • The minimum IP bandwidth required for Continuous Access EVA4400/6400/8400 and EVA4400 (embedded switch) with FCIP is 2 Mb/s per path, or 4 Mb/s for two paths when using one IP link. • There is no support for dynamic pacing of the gateway. Maximum number of DR groups See Table 131 for the maximum number of DR groups. See Table 155 and Table 156 for minimum supported bandwidth and resulting maximum number of DR groups based on the average packet-loss ratio and one-way inter-site latencies. MTU of the IP network 1,500 bytes Maximum latency1 100 ms IP network delay one-way or 200 ms round-trip Average packet-loss ratio2 Low-loss network: 0.0012% average over 24 hours High-loss network: 0.2% average over 24 hours; must not exceed 0.5% for more than 5 minutes in a two-hour window Latency jitter3 Must not exceed 10 ms over 24 hours 1Pre-existing restriction 2A high packet-loss ratio indicates the need to retransmit data across the inter-site link. Each retransmission delays transmissions queued behind the current packet, thus increasing the time to complete pending transactions. Unless noted otherwise, gateways listed in Table 155 and Table 156 are supported in both low-loss and high-loss networks. 3Latency jitter is the difference between the minimum and maximum values, and indicates how stable or predictable the network delay. The greater the jitter, the greater the variance in the delay, which lowers the performance predictability. NOTE: Applications typically require more than the minimum bandwidth to meet throughput requirements. To increase the maximum number of DR groups, you must increase the minimum available IP bandwidth. For example, if the maximum number of DR groups required is 10, increase the minimum available bandwidth to 10 Mb/s; for 15 DR groups, increase it to 15 Mb/s; and for 128 DR groups, increase it to 128 Mb/s. Table 155 describes the network bandwidth requirements and IP gateway support for XCS 09x with B-series switches. SAN Design Reference Guide 325