When the switch name is set using CLI and then read using the Read Port Address Name x'B2' command to the CUP Port x'FE' it returns the switch name with a x'7F' attach after the last character in the Switch Name. Fixed in Fabric OS 6.2.0. A failed Pause frame (sent during firmwaredownload process in Interop Modes 2 and 3), causes a fabric rebuild. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Use the -o option to override the cooperative HCL feature. In some instances, HCL on an HP StorageWorks 8/40 SAN switch in Interop Mode requires the use of the -o option. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Use the -o option. A turboramtest failure does not fully disable the port on an HP StorageWorks 8/80 SAN switch. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Reboot the switch. Web Tools: The HP StorageWorks DC04 SAN Director attention LEDs on the switch view GUI window do not turn amber when blade needs Fixed in Fabric OS 6.2.0. attention. N-Port between AG and Edge Switch (300) may become stuck at E_Port Unknown state.D Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Disable and then enable the port on the AG to bring the port back online as an N-Port. After multiple successive fastboots of an HP StorageWorks DC04 SAN Director, there was a panic due to the zone daemon dying. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Fastboot a single time. FICON PTP VTS Selective Resets and Aborted sequences caused by incorrect entry into FICON tape read pipelining. Fixed in Fabric OS 6.2.0. EX_Port fails to come online after downgrading firmware from Fabric OS 6.x to 5.3 under certain conditions. Fixed in Fabric OS 6.2.0. Tstimezone settings cannot be changed or restored with configdownload. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Remove the ts.tz parameter in the config file and then download. If a large number of EX_Ports are enabled at the same time, occasionally some fail due to incompatible flow control parameters. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Portdisable and then enable the EX_Ports that failed. In some instances, portshow may display inaccurate port authentication description or state after a CP failover. Fixed in Fabric OS 6.2.0. Internal server ports on embedded platform: traffic may stop due to loss of buffer credit. Fixed in Fabric OS 6.2.0. HP StorageWorks Fabric OS 6.2.0e release notes 37