HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0e release notes (5697-0354 - Page 52

Registered Link Incident Records RLIR with Loss of Light LOL are being

Page 52 highlights

E-Port Class Link Resets are not fencing. RASLOG message will be presented indicating link resets are above threshold, but the port will not have been fenced as expected. Fixed in Fabric OS 6.2.0d RNID data reporting same serial number for two different logical switches in FICON environment, as user entered FRU number via CLI is not being modified. Fixed in Fabric OS 6.2.0e Detected termination of process fabricd:4120 followed by software verify errors due to HP StorageWorks DC SAN Director being unresponsive. Fixed in Fabric OS 6.2.0e Partitioned HP StorageWorks DC04 Director in FICON environment panicked after reset allegiance issued by multiple hosts, leading to FICUD terminating and switch reboot. Fixed in Fabric OS 6.2.0e SNMPd panics and generates a core file that can fill up the root file system. User will observe snmpd process being killed and Detected Fixed in Fabric OS 6.2.0e termination of process error message. Node descriptors missing from FICON RNID data for HP StorageWorks Fixed in Fabric OS 6.2.0e DC SAN Director and HP StorageWorks DC04 Director. Tape pipelining code randomly sends only data frames in an exchange Fixed in Fabric OS 6.2.0e to a tape drive over an FCIP link, leading to tape job failure. Portswap does not work for ports 32 - 47 on 48 port blade via the GUI for FICON. Fixed in Fabric OS 6.2.0e Registered Link Incident Records (RLIR) with Loss of Light (LOL) are being generated on 8 Gb channels during CEC Initial Machine Load (IML) Fixed in Fabric OS 6.2.0e in FICON environment. Tape pipelining code does not close exchange upon an ELS RJT response to REC -- invalid oxid/rxid combo causing write sequence failures. Tape reads are unaffected. Fixed in Fabric OS 6.2.0e FC Fastwrite corrupts buffer pool upon Turbo Write Block (TWB) alloc- Fixed in Fabric OS 6.2.0e ation failure on Proxy Initiator leading to I/O failure. With HP StorageWorks DC SAN Director, Web Tools shows high host CPU usage (approximately 80%) when port configuration operation is performed on a large system. CPU usage goes back to normal once operation completes. Fixed in Fabric OS 6.2.0e Supportsave may show parity errors on disabled ports on a switch that has been upgraded from a lower code level to Fabric OS 6.1.2 and never cold booted. No errors will be caused on enabled ports, or after a disabled port is enabled. Fixed in Fabric OS 6.2.0e When a blade is hot plugged into an HP StorageWorks DC SAN Director or HP StorageWorks DC04 Director, its information will not appear in the embedded GUI. Fixed in Fabric OS 6.2.0e Lossless DLS failed with dropped frame causing IFCC in presence of Fixed in Fabric OS 6.2.0e ICLs. 52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

Fixed in Fabric OS 6.2.0d
E-Port Class Link Resets are not fencing. RASLOG message will be
presented indicating link resets are above threshold, but the port will
not have been fenced as expected.
Fixed in Fabric OS 6.2.0e
RNID data reporting same serial number for two different logical
switches in FICON environment, as user entered FRU number via CLI
is not being modified.
Fixed in Fabric OS 6.2.0e
Detected termination of process fabricd:4120 followed by software
verify errors due to HP StorageWorks DC SAN Director being unre-
sponsive.
Fixed in Fabric OS 6.2.0e
Partitioned HP StorageWorks DC04 Director in FICON environment
panicked after reset allegiance issued by multiple hosts, leading to
FICUD terminating and switch reboot.
Fixed in Fabric OS 6.2.0e
SNMPd panics and generates a core file that can fill up the root file
system. User will observe snmpd process being killed and
Detected
termination of process
error message.
Fixed in Fabric OS 6.2.0e
Node descriptors missing from FICON RNID data for HP StorageWorks
DC SAN Director and HP StorageWorks DC04 Director.
Fixed in Fabric OS 6.2.0e
Tape pipelining code randomly sends only data frames in an exchange
to a tape drive over an FCIP link, leading to tape job failure.
Fixed in Fabric OS 6.2.0e
Portswap does not work for ports 32 - 47 on 48 port blade via the
GUI for FICON.
Fixed in Fabric OS 6.2.0e
Registered Link Incident Records (RLIR) with Loss of Light (LOL) are being
generated on 8 Gb channels during CEC Initial Machine Load (IML)
in FICON environment.
Fixed in Fabric OS 6.2.0e
Tape pipelining code does not close exchange upon an ELS RJT re-
sponse to REC --
invalid oxid/rxid combo
causing write se-
quence failures. Tape reads are unaffected.
Fixed in Fabric OS 6.2.0e
FC Fastwrite corrupts buffer pool upon Turbo Write Block (TWB) alloc-
ation failure on Proxy Initiator leading to I/O failure.
Fixed in Fabric OS 6.2.0e
With HP StorageWorks DC SAN Director, Web Tools shows high host
CPU usage (approximately 80%) when port configuration operation
is performed on a large system. CPU usage goes back to normal once
operation completes.
Fixed in Fabric OS 6.2.0e
Supportsave
may show parity errors on disabled ports on a switch
that has been upgraded from a lower code level to Fabric OS 6.1.2
and never cold booted. No errors will be caused on enabled ports,
or after a disabled port is enabled.
Fixed in Fabric OS 6.2.0e
When a blade is hot plugged into an HP StorageWorks DC SAN
Director or HP StorageWorks DC04 Director, its information will not
appear in the embedded GUI.
Fixed in Fabric OS 6.2.0e
Lossless DLS failed with dropped frame causing IFCC in presence of
ICLs.
52