HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0e release notes (5697-0354 - Page 49
Fabric OS 6.2.0d fixes
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Repeatedly disconnecting and reconnecting ISL links between the HP StorageWorks Encryption SAN Switch in an HA cluster environment while rekey operations are in progress may cause data miscompare. Fixed in Fabric OS 6.2.0c Internal recovery scheme can attempt to correct a valid Frame Redirection RAM Filter, which can lead to one existing filter being corrupted, Fixed in Fabric OS 6.2.0c potentially causing misrouted frames. This is a very rare occurrence. Running configdefault may cause kernel panic on an HP Storage- Fixed in Fabric OS 6.2.0c Works 4/256 SAN Director. An unexpected switch panic can occur when supportsave reads invalid data on GE ports without FC Fast Write enabled. Fixed in Fabric OS 6.2.0c FICON XRC times out on an HP StorageWorks 400 MP Router to HP StorageWorks DC SAN Director, which causes drives not to come online. Fixed in Fabric OS 6.2.0c Need support in Fabric OS for DWDM-SFP media. Enabled new SFP support in Fabric OS 6.2.0c HP StorageWorks 8/40 SAN Switch did not indicate a warning when Fixed in Fabric OS 6.2.0c a PS/FAN FRU was removed. High temperature alerts are reported on an HP StorageWorks DC Switch Encryption Blade when the ambient temperature is 39o Celsius. Fixed in Fabric OS 6.2.0c Fabric OS 6.2.0d fixes The following table lists defects closed in the Fabric OS 6.2.0d firmware release. Table 13 Fabric OS 6.2.0d closed defects Closed defect summary Solution Brocade 8-Gb SAN Switch for HP BladeSystem c-Class requires up- Updated serdes values are provided dated serdes values for proper operation with 8-Gb mezzanine HBAs. in Fabric OS 6.2.0d. An out-of-memory condition can occur, leading to a switch panic due Fixed in Fabric OS 6.2.0d to memory leak when an E_Port constantly goes on and off. An out-of-memory condition can occur during hafailover/hareboot, leading to a switch panic due to memory leak when querying connUnitPortFCId in Access Gateway mode, as well as when querying FcFeModuleName. Workaround prior to upgrade: Avoid querying FcFeModuleName or connUnitPortFCId in AG mode. Fixed in Fabric OS 6.2.0d On rare occasions, HP StorageWorks DC SAN Director may panic in RTE module and hafailover during supportsave. Fixed in Fabric OS 6.2.0d During HA recovery, Fabric Watch reports switch health as marginal/down on fully populated HP StorageWorks DC SAN Director. Traffic Fixed in Fabric OS 6.2.0d is not impacted, but DCFM call home will not be initiated. After HAfailover, SNMP v3 user configuration reverts back to default values when configuring SNMP v3 user configuration on any one of Fixed in Fabric OS 6.2.0d the user-defined USM configuration sets. HP StorageWorks Fabric OS 6.2.0e release notes 49