HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0g release notes (5697-0035 - Page 27

HP Encryption Switch or HP Encryption Blade, the LUN can be added to the Crypto Target

Page 27 highlights

• The following process is to be used then when configuring a LUN for encryption: • Add the LUN as clear-text to the Crypto Target Container (CTC). • Once the LUN comes online and clear-text host I/O starts, modify the LUN from clear-text to encrypt, including the enable_encexistingdata option to convert the LUN from clear-text to encrypted. • An exception to this LUN configuration process: if the LUN was previously encrypted by the HP Encryption Switch or HP Encryption Blade, the LUN can be added to the Crypto Target Container with the -encrypt and -lunstate ="encrypted" options. • LUN configurations must be committed to take effect. No more than 25 LUNs can be added or modified in a single commit operation. Attempts to commit configurations that exceed 25 LUNs will fail with a warning. Note that there is also a five-second delay before the commit operation takes effect. Always ensure that any previously committed LUN configurations or LUN modifications have taken effect before committing additional LUN configurations or additions. All LUNs should be in an Encryption Enabled state before committing additional LUN modifications. • Avoid changing the configuration of any LUN that belongs to a Crypto Target Container/LUN configuration while the re-keying process for that LUN is active. If the user changes the LUN's settings during manual or auto, re-keying or First Time Encryption, the system reports a warning message stating that the encryption engine is busy and a forced commit is required for the changes to take effect. A forced commit command halts all active re-keying processes running in all Crypto Target Containers and corrupts any LUN engaged in a re-keying operation. There is no recovery for this type of failure. • To remove access between a given initiator and target, the user must not only remove the active zoning information between the initiator and target, but must also remove the associated Crypto Target Containers (CTCs), which will in turn remove the associated frame redirection zone information. • Before committing configurations or modifications to the CTC or LUNs on an HP Encryption Switch or HP Encryption Blade, make sure that there are no outstanding zoning transactions in the switch or fabric. Failure to do so results in the commit operation for the Crypto Target or LUNs failing and may cause the LUNs to be disabled. The user can check for outstanding zoning transaction by issuing the cfgtransshow CLI command: DCX_two:root> cfgtransshow There is no outstanding zoning transaction • Each LUN is uniquely identified by the HP Encryption Switch or HP Encryption Blade using the LUN's serial number. The LUN serial numbers must be unique for LUNs exposed from the same target port. The LUN serial numbers must also be unique for LUNs belonging to different target ports in non-multipathing configurations. Failure to ensure unique LUN serial numbers results in non-deterministic behavior and may result in faulting of the HP Encryption Switch or HP Encryption Blade. • When creating an HA Cluster or Encryption Group with two or more HP Encryption Switch/Encryption Blades, the GE Ports (I/O sync links) must be configured with an IP address for the eth0 Ethernet interface using ipaddrset. In addition, both eth0 and eth1 Ethernet ports should be connected to the network for redundancy. These I/O sync links connections must be established before any Re-Key, First Time Encryption, or enabling EE for crypto operations. Failure to do so results in HA Cluster creation failure. If the IP address for these ports is configured after the EE was enabled for encryption, HP Encryption Switch needs to be rebooted and Encryption blades should be slotpoweroff/slotpoweron to sync up the IP address information to the EEs. If only one Ethernet port is configured and connected to a network, data loss or suspension of ReKey may occur when the network connection toggles or fails. HP StorageWorks Fabric OS 6.2.0g release notes 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

The following process is to be used then when configuring a LUN for encryption:
Add the LUN as clear-text to the Crypto Target Container (CTC).
Once the LUN comes online and clear-text host I/O starts, modify the LUN from clear-text
to
encrypt
, including the
enable_encexistingdata
option to convert the LUN from
clear-text to encrypted.
An exception to this LUN configuration process: if the LUN was previously encrypted by the
HP Encryption Switch or HP Encryption Blade, the LUN can be added to the Crypto Target
Container with the
–encrypt
and
–lunstate =“encrypted”
options.
LUN configurations must be committed to take effect. No more than 25 LUNs can be added
or modified in a single commit operation. Attempts to commit configurations that exceed 25
LUNs will fail with a warning. Note that there is also a five-second delay before the commit
operation takes effect.
Always ensure that any previously committed LUN configurations or LUN modifications have
taken effect before committing additional LUN configurations or additions. All LUNs should be
in an Encryption Enabled state before committing additional LUN modifications.
Avoid changing the configuration of any LUN that belongs to a Crypto Target Container/LUN
configuration while the re-keying process for that LUN is active. If the user changes the LUN’s
settings during manual or auto, re-keying or First Time Encryption, the system reports a warning
message stating that the encryption engine is busy and a forced commit is required for the changes
to take effect. A forced commit command halts all active re-keying processes running in all Crypto
Target Containers and corrupts any LUN engaged in a re-keying operation. There is no recovery
for this type of failure.
To remove access between a given initiator and target, the user must not only remove the active
zoning information between the initiator and target, but must also remove the associated Crypto
Target Containers (CTCs), which will in turn remove the associated frame redirection zone inform-
ation.
Before committing configurations or modifications to the CTC or LUNs on an HP Encryption Switch
or HP Encryption Blade, make sure that there are no outstanding zoning transactions in the switch
or fabric. Failure to do so results in the commit operation for the Crypto Target or LUNs failing
and may cause the LUNs to be disabled. The user can check for outstanding zoning transaction
by issuing the
cfgtransshow
CLI command:
DCX_two:root> cfgtransshow
There is no outstanding zoning transaction
Each LUN is uniquely identified by the HP Encryption Switch or HP Encryption Blade using the
LUN’s serial number. The LUN serial numbers must be unique for LUNs exposed from the same
target port. The LUN serial numbers must also be unique for LUNs belonging to different target
ports in non-multipathing configurations. Failure to ensure unique LUN serial numbers results in
non-deterministic behavior and may result in faulting of the HP Encryption Switch or HP Encryption
Blade.
When creating an HA Cluster or Encryption Group with two or more HP Encryption Switch/En-
cryption Blades, the GE Ports (I/O sync links) must be configured with an IP address for the
eth0
Ethernet interface using
ipaddrset
. In addition, both
eth0
and
eth1
Ethernet ports should be
connected to the network for redundancy. These I/O sync links connections must be established
before any Re-Key, First Time Encryption, or enabling EE for crypto operations. Failure to do so
results in HA Cluster creation failure. If the IP address for these ports is configured after the EE
was enabled for encryption, HP Encryption Switch needs to be rebooted and Encryption blades
should be
slotpoweroff
/
slotpoweron
to sync up the IP address information to the EEs. If
only one Ethernet port is configured and connected to a network, data loss or suspension of Re-
Key may occur when the network connection toggles or fails.
HP StorageWorks Fabric OS 6.2.0g release notes
27