HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0g release notes (5697-0035 - Page 38

Kernel Panic on 8Gb SAN Switch for HP BladeSystem c-Class after - - san switch manual

Page 38 highlights

Fast Write will attempt to configure, even on an HP StorageWorks Bseries Multi-protocol Router blade that has failed to initialize successfully. Fixed in Fabric OS 6.2.0. Zoned crashes after HP StorageWorks DC SAN Backbone Director power cycle and zone transaction aborted Fixed in Fabric OS 6.2.0. SMIA does not have information about SFP/GBIC type for a port. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: The embedded platforms have well known user/server ports documented in the user manuals. The tag field of the node identifier command returned contains the port number on which the command was received, instead of the tag field Fixed in Fabric OS 6.2.0. of the device on the other end of the link. Gzoneinfo.htm is returning empty zone information on fabric with Fabric OS 6.1.1. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Reboot the switch. Kernel Panic on 8Gb SAN Switch for HP BladeSystem c-Class after firmwaredownload. Fixed in Fabric OS 6.2.0. Conversion of uwatt to dbm for GE ports Tx Rx values shown in Web Tools are incorrect. Fixed in Fabric OS 6.2.0. HP StorageWorks 8/40 SAN Switch: FRU faulty status is not recovered correctly. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Turn on the power switch as soon as possible after inserting a fan/power supply unit into the system. Third-party array responds to ADISC with LOGO only over router fabric, S_ID does not match N_ID. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: For McDATA mode edge fabric, only McDATA switches have to be connected directly to FCR. The work around is valid as long as we have only McDATA switches directly connected to Ex-Ports. Ipfilter - Audit log (SEC- 3035, 3036, 3037): message properties generating log without the appropriate key word. Fixed in Fabric OS 6.2.0. AG trunks are not formed correctly when connected to an embedded switch. Fixed in Fabric OS 6.2.0. Tape Selective Reset error due to incorrect handling of Early End Synchronization status. Fixed in Fabric OS 6.2.0. F_Port prefers to multiple N_Ports Fixed in Fabric OS 6.2.0. FICON Device Level Ack Emulation Processing error. Fixed in Fabric OS 6.2.0. 38

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Fixed in Fabric OS 6.2.0.
Fast Write will attempt to configure, even on an HP StorageWorks B-
series Multi-protocol Router blade that has failed to initialize success-
fully.
Fixed in Fabric OS 6.2.0.
Zoned crashes after HP StorageWorks DC SAN Backbone Director
power cycle and zone transaction aborted
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
The embedded platforms have well
known user/server ports documented
in the user manuals.
SMIA does not have information about SFP/GBIC type for a port.
Fixed in Fabric OS 6.2.0.
The tag field of the node identifier command returned contains the port
number on which the command was received, instead of the tag field
of the device on the other end of the link.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch.
Gzoneinfo.htm
is returning empty zone information on fabric with
Fabric OS 6.1.1.
Fixed in Fabric OS 6.2.0.
Kernel Panic on 8Gb SAN Switch for HP BladeSystem c-Class after
firmwaredownload
.
Fixed in Fabric OS 6.2.0.
Conversion of uwatt to dbm for GE ports Tx Rx values shown in Web
Tools are incorrect.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Turn on the power switch as soon as
possible after inserting a fan/power
supply unit into the system.
HP StorageWorks 8/40 SAN Switch: FRU faulty status is not recovered
correctly.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
For McDATA mode edge fabric, only
McDATA switches have to be connec-
ted directly to FCR. The work around
is valid as long as we have only
McDATA switches directly connected
to Ex-Ports.
Third-party array responds to ADISC with LOGO only over router
fabric, S_ID does not match N_ID.
Fixed in Fabric OS 6.2.0.
Ipfilter – Audit log (SEC- 3035, 3036, 3037): message properties
generating log without the appropriate key word.
Fixed in Fabric OS 6.2.0.
AG trunks are not formed correctly when connected to an embedded
switch.
Fixed in Fabric OS 6.2.0.
Tape Selective Reset error due to incorrect handling of Early End Syn-
chronization status.
Fixed in Fabric OS 6.2.0.
F_Port prefers to multiple N_Ports
Fixed in Fabric OS 6.2.0.
FICON Device Level Ack Emulation Processing error.