HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0g release notes (5697-0035 - Page 35

On an HP StorageWorks 8/80 SAN Switch, the system status LED - storageworks 11 8 80

Page 35 highlights

EE monitor counters may not get updated after performing switchdisable/switchenble or reboot. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Retrieve all EE monitors from the FLASH by issuing perfcfgrestore. All EE monitor counters will be properly updated. Static routing does not affect dynamic routes with DLS ON on supported platforms. Fixed in Fabric OS 6.2.0. The gzoneinfo.htm page returns empty data when CLI actually shows defined/eff cfg zone info for fabric. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Do any other HTTP post operation from DCFM and then you see both the old data and the newly pushed zone info. Rebooting the switch sometimes helps. Third-party storage center application does not survive in an FCIP network with 1% packet loss and 100 ms network latency. Fixed in Fabric OS 6.2.0. Traffic Isolation failover policy reverts back to disabled from enabled after changing the port membership list. Fixed in Fabric OS 6.2.0. Hareboot on HP StorageWorks 400 Multi-protocol Router FC Fast Write enabled switch causes the system to panic with "Oops: kernel access of bad area, sig: 11 [#1]." Fixed in Fabric OS 6.2.0. Fabric Mode TT displays redundant flows with different values for the same SID/DID pair on the core switches when there are redundant trunk groups to the same edge domain. Fixed in Fabric OS 6.2.0. DLS ON does not rebalance when ISLs to a different switch are removed on HP StorageWorks DC SAN Backbone Director and HP StorageWorks 8/80 SAN Switch. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Perform switchdisable and switchenable to force a rebalance of the routes. On an HP StorageWorks 8/80 SAN Switch, the system status LED does not flash amber/green when a power supply is faulted. Fixed in Fabric OS 6.2.0. User with admin role in some AD is able to add another user with admin role in AD as ALL. Fixed in Fabric OS 6.2.0. Reset to default button is grayed out always in SCSI vs. IP traffic setup window. Fixed in Fabric OS 6.2.0. USB Admin is not in sync with CLI when launched . It shows the correct info only when we click refresh button. Fixed in Fabric OS 6.2.0. Name Server database is being set with incorrect WWN's for NPIV nodes when port ALPA = 0x13. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Port ALPA must be set to default value of 0x00 for ports hosting NPIV nodes. Potential timeouts and aborts during Device Discovery and CU busy processing when using FICON XRC Emulation. Fixed in Fabric OS 6.2.0. HP StorageWorks Fabric OS 6.2.0g release notes 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Retrieve all EE monitors from the
FLASH by issuing
perfcfgrestore
.
All EE monitor counters will be prop-
erly updated.
EE monitor counters may not get updated after performing
switch-
disable
/
switchenble
or reboot.
Fixed in Fabric OS 6.2.0.
Static routing does not affect dynamic routes with DLS ON on supported
platforms.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Do any other HTTP post operation
from DCFM and then you see both
the old data and the newly pushed
zone info. Rebooting the switch
sometimes helps.
The
gzoneinfo.htm
page returns empty data when CLI actually
shows defined/eff cfg zone info for fabric.
Fixed in Fabric OS 6.2.0.
Third-party storage center application does not survive in an FCIP
network with 1% packet loss and 100 ms network latency.
Fixed in Fabric OS 6.2.0.
Traffic Isolation failover policy reverts back to disabled from enabled
after changing the port membership list.
Fixed in Fabric OS 6.2.0.
Hareboot
on HP StorageWorks 400 Multi-protocol Router FC Fast
Write enabled switch causes the system to panic with "Oops: kernel
access of bad area, sig: 11 [#1]."
Fixed in Fabric OS 6.2.0.
Fabric Mode TT displays redundant flows with different values for the
same SID/DID pair on the core switches when there are redundant
trunk groups to the same edge domain.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Perform
switchdisable
and
switchenable
to force a rebalance
of the routes.
DLS ON does not rebalance when ISLs to a different switch are re-
moved on HP StorageWorks DC SAN Backbone Director and HP
StorageWorks 8/80 SAN Switch.
Fixed in Fabric OS 6.2.0.
On an HP StorageWorks 8/80 SAN Switch, the system status LED
does not flash amber/green when a power supply is faulted.
Fixed in Fabric OS 6.2.0.
User with admin role in some AD is able to add another user with
admin role in AD as ALL.
Fixed in Fabric OS 6.2.0.
Reset to default
button is grayed out always in SCSI vs. IP traffic setup
window.
Fixed in Fabric OS 6.2.0.
USB Admin is not in sync with CLI when launched . It shows the correct
info only when we click refresh button.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Port ALPA must be set to default value
of 0x00 for ports hosting NPIV nodes.
Name Server database is being set with incorrect WWN's for NPIV
nodes when port ALPA = 0x13.
Fixed in Fabric OS 6.2.0.
Potential timeouts and aborts during Device Discovery and CU busy
processing when using FICON XRC Emulation.
HP StorageWorks Fabric OS 6.2.0g release notes