IBM 419452u Installation Guide - Page 51

Problem, Determination, Service, Guide

Page 51 highlights

Table 4. Abbreviated list of POST error codes (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 164 Memory size has changed. 1. Run the Configuration/Setup Utility program; then, exit, saving the configuration settings. 2. Reseat the DIMMs. 184 Power-on password damaged. 1. Run the Configuration/Setup Utility program, select Load Default Settings, and save the settings. 2. Reseat the battery. 3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Battery b. (Trained service technician only) System board 187 VPD serial number not set. 1. Reseat the optional Remote Supervisor Adapter II SlimLine. 2. (Trained service technician only) Replace the system board. 189 Three attempts were made to Restart the server and enter the access the server with an incorrect administrator password; then, run password. the Configuration/Setup Utility program and change the power-on password. 289 A failing DIMM was disabled. 1. Make sure that the DIMM is installed correctly (see "Installing a memory module" on page 14). 2. Reseat the DIMM. 3. Replace the DIMM. Chapter 5. Solving problems 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

Table
4.
Abbreviated
list
of
POST
error
codes
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
164
Memory
size
has
changed.
1.
Run
the
Configuration/Setup
Utility
program;
then,
exit,
saving
the
configuration
settings.
2.
Reseat
the
DIMMs.
184
Power-on
password
damaged.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
Reseat
the
battery.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
187
VPD
serial
number
not
set.
1.
Reseat
the
optional
Remote
Supervisor
Adapter
II
SlimLine.
2.
(Trained
service
technician
only)
Replace
the
system
board.
189
Three
attempts
were
made
to
access
the
server
with
an
incorrect
password.
Restart
the
server
and
enter
the
administrator
password;
then,
run
the
Configuration/Setup
Utility
program
and
change
the
power-on
password.
289
A
failing
DIMM
was
disabled.
1.
Make
sure
that
the
DIMM
is
installed
correctly
(see
“Installing
a
memory
module”
on
page
14).
2.
Reseat
the
DIMM.
3.
Replace
the
DIMM.
Chapter
5.
Solving
problems
37