    Intel® Server Chassis H2000 Family Technical Product Specification Intel order number: G59059-001 Revision 1.0 February, 2012 Enterprise Platforms and Services Division
  • Intel H2000WP | Technical Product Specification - Page 2
    Revision History Intel® Server Chassis H2000 Family TPS Revision History Date February, 2012 Revision Number 1.0 Initial release. Modifications ii Revision 1.0 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 3
    characteristics of any features or instructions marked "reserved" or "undefined". Intel® reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Intel® Server System H2000JF Family may contain design
  • Intel H2000WP | Technical Product Specification - Page 4
    Table of Contents Intel® Server Chassis H2000 Family TPS Table of Contents 1. Introduction ...1 1.1 Chapter Outline ...1 1.2 Server Board Use Disclaimer 2 2. Product Overview ...3 2.1 Chassis Views...4 2.2 Chassis Dimensions 5 2.3 System Level Environmental Limits 5 2.4 Chassis
  • Intel H2000WP | Technical Product Specification - Page 5
    Intel® Server Chassis H2000 Family TPS Table of Contents 3.2.17 AC Line Isolation 17 3.2. Lines A0 26 3.7.2 Accuracy ...27 4. Cooling Sub-System...28 4.1 Power Supply Fan 28 4.2 Drive Bay Population Requirement 28 5. Hard Disk Drive Support 29 5.1 Hard Disk Drive Bays Scheme 29 5.2
  • Intel H2000WP | Technical Product Specification - Page 6
    Table of Contents Intel® Server Chassis H2000 Family TPS 5.3.3 3.5" Hot Swap Backplane Connector scheme 32 5.3.4 2.5" Hot Swap Backplane Connector scheme 33 5.3.5 Backplane LED Support 34 5.3.6 Backplane Connector Definition 35 6. Front Panel Control and Indicators 39 6.1 Control Panel
  • Intel H2000WP | Technical Product Specification - Page 7
    2. Power Supply Scheme (Rear View 4 Figure 3. Dummy Tray Cover ...4 Figure 4. Major Chassis Parts ...6 Figure 5. Intel® Server Chassis H2312xx Drive Bay Front View 7 Figure 6. Intel® Server Chassis H2216xx Drive Bay Front View 7 Figure 7. Chassis Bezel Front View 7 Figure 8. AC Power Supply Unit
  • Intel H2000WP | Technical Product Specification - Page 8
    List of Tables Intel® Server Chassis H2000 Family TPS List of Tables Table 1. Chassis Feature Set...3 Table 2. Chassis SKU Matrix ...3 Table 3. Chassis Dimension (SKU: H2312xxJR/KR 5 Table 4. Chassis Dimension (SKU: H2216xxJR/KR 5 Table 5. System Environmental Limits Summary 5 Table 6.
  • Intel H2000WP | Technical Product Specification - Page 9
    Intel® Server Chassis H2000 Family TPS List of Tables Table 40. Power Supply Control Connector Pin-out 38 Table 41. Front Control Button Function 40 Table 42. Front LED Indicator Functions 40 Table 43. Power LED Operation 41 Table 44. System Status LED Operation 41 Revision 1.0 ix Intel
  • Intel H2000WP | Technical Product Specification - Page 10
    List of Tables Intel® Server Chassis H2000 Family TPS x Revision 1.0 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 11
    information detailing the features, functionality, and high-level architecture of the Intel® Server Chassis H2000 family. You should also reference the Intel® Server System H2000JF, H2000WP, H2000LP Family Technical Product Specification to obtain greater detail of functionality and architecture
  • Intel H2000WP | Technical Product Specification - Page 12
    Board Use Disclaimer Intel Corporation server boards support add-in peripherals and contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel® ensures through its own chassis development and testing that when Intel® server building blocks are
  • Intel H2000WP | Technical Product Specification - Page 13
    2U 4-node server systems, purpose-built for high-density and lowest total cost of ownership in dense computing applications, such as HPC and IPDC. The chassis can be used to integrate with four units of node trays which are built with Intel® Server Board S2600JF, S2600WP or S2400LP, supports up to
  • Intel H2000WP | Technical Product Specification - Page 14
    Product Overview 2.1 Chassis Views Intel® Server Chassis H2000 Family TPS Figure 1. Chassis Overview (H2312xx SKU) Figure 2. Power Supply Scheme (Rear View) Figure 3. Dummy Tray Cover 4 Revision 1.0 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 15
    Intel® Server Chassis H2000 Family TPS Product Overview 2.2 Chassis Dimensions Table 3. Chassis " 28.86" 2.3 System Level Environmental Limits The following table defines the system level operating and non-operating environmental limits. Table 5. System Environmental Limits Summary Parameter
  • Intel H2000WP | Technical Product Specification - Page 16
    Product Overview Intel® Server Chassis H2000 Family TPS Parameter ESD Altitude Line to earth Only AC Leads I/O Leads DC Leads 2.0 kV 1.0 kV Supply E Hot Swap Back Plane Note: Not shown - Rack slide rail, and top cover. Figure 4. Major Chassis Parts 6 Intel order number: G59059-001 Revision 1.0
  • Intel H2000WP | Technical Product Specification - Page 17
    inch) SATA/SAS Hard Disk Drives (2.5-inch) Intel® Server System H2312xx Not Supported Not Supported Up to Twelve Not Supported Product Overview Intel® Server System H2216xx Not Supported Not Supported Not Supported Up to Sixteen Figure 5. Intel® Server Chassis H2312xx Drive Bay Front View Figure
  • Intel H2000WP | Technical Product Specification - Page 18
    Product Overview Intel® Server Chassis H2000 Family TPS  A basic slide rail kit (Product order code - AXXELVRAIL) is designed to mount the chassis into a standard (19 inches by up to 30 inches deep) EIA-310D compatible server cabinet. 8 Revision 1.0 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 19
    Intel® Server Chassis H2000 Family TPS Power Sub-System 3. Power Sub-System The system supports AC 1+1 hot swap power supply module and two power distribution board which can support 2U rack high density server system. Two different power supply units are supported: 1200W and 1600W. The single
  • Intel H2000WP | Technical Product Specification - Page 20
    Power Sub-System Intel® Server Chassis H2000 Family TPS Table 6. Specification Data for AC VAC, auto-ranging, 47 Hz-63 Hz 2560 BTU/hr Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 65 A per power supply for 5 ms Platinum Platinum
  • Intel H2000WP | Technical Product Specification - Page 21
    Intel® Server Chassis H2000 Family TPS Power Sub-System PSU Output Connector A18 +12V B18 +12V A19 PMBus SDA of two Power Distribution Boards (PDB) to support Common Redundant Power Supplies (CRPS). Below is the power system overview. Revision 1.0 11 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 22
    Sub-System Intel® Server Chassis H2000 Family TPS A Power Distribution Board 1 B Power Distribution Board 2 C Power Supply Unit #2(upper) and #1(lower) Figure 9. Power Cage Overview 3.1.9 Power Cage Output Pin Assignment The power cage provides +12V and +12VSTB output to the system. Each
  • Intel H2000WP | Technical Product Specification - Page 23
    Intel® Server Chassis H2000 Family TPS Power Sub-System A Main Power Output Connector P1 B Power Supply Unit Connector C Control Signal Connector D 2 A0 (SMBus Address) 4 A1 (SMBus Address) 6 12V Load Share Bus 8 Cold Redundancy Bus Revision 1.0 13 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 24
    Power Sub-System Intel® Server Chassis H2000 Family TPS Pin Description 9 Return Sense must meet the power factor requirements stated in the Energy Star® Program Requirements for Computer Servers. These requirements are stated below. Table 13. Typical power factor Output power Power factor
  • Intel H2000WP | Technical Product Specification - Page 25
    Intel® Server Chassis H2000 Family TPS Power Sub-System Table 14. Platinum Efficiency Requirement Loading Minimum Efficiency 100% of maximum 91% 50% of 3 requirements for surge-withstand capability, with the following conditions and exceptions: Revision 1.0 15 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 26
    Power Sub-System Intel® Server Chassis H2000 Family TPS  These input transients must not cause any defined in Annex B of CISPR 24. 3.2.13 Surge Immunity The power supply shall be tested with the system for immunity to AC Ring wave and AC Unidirectional wave, both up to 2kV, per EN 55024:1998,
  • Intel H2000WP | Technical Product Specification - Page 27
    Intel® Server Chassis H2000 Family TPS Power Sub-System 3.2.14 AC Line Transient Specification AC line transient conditions shall voltage the highest test voltage should be used. In addition the insulation system must comply with reinforced insulation per safety standard IEC 950. Separation
  • Intel H2000WP | Technical Product Specification - Page 28
    Power Sub-System Intel® Server Chassis H2000 Family TPS The AC power cord must meet the 1600W (for 1200W PSU) and 2100W (for 1600W PSU) 3. Length of time peak power can be supported is based on thermal sensor and assertion of the SMBAlert# signal. Minimum peak power duration shall be 20 seconds
  • Intel H2000WP | Technical Product Specification - Page 29
    Intel® Server Chassis H2000 Family TPS Power Sub-System Table 20. Voltage Regulation Limits Parameter +12VSTB +12V Min +11.40V +11.40V Nom +12.000V with a 0.1F ceramic capacitor is placed at the point of measurement. Table 23. Ripple and Noise Revision 1.0 19 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 30
    Power Sub-System Intel® Server Chassis H2000 Family TPS +12V 120mVp-p +12VSTB 120mVp-p 3.3.7 Grounding be immune to any residual voltage placed on its outputs (Typically a leakage voltage through the system from standby output) up to 500mV. There shall be no additional heat generated, nor
  • Intel H2000WP | Technical Product Specification - Page 31
    Intel® Server Chassis H2000 Family TPS Power Sub-System 3.3.12 Zero Load Stability Requirement When the a redundant power supply does not cause these outputs to go out of regulation in the system. 3.3.15 Timing Requirement These are the timing requirements for the power supply operation. The
  • Intel H2000WP | Technical Product Specification - Page 32
    Power Sub-System Intel® Server Chassis H2000 Family TPS Item Description Min. asserted at turn on Figure 12. Turn On/Off Timing (Power Supply Signals) 3.4 Power Supply Cold Redundancy Support Power supplies that support cold redundancy can be enabled to go into a low-power state (that is, cold
  • Intel H2000WP | Technical Product Specification - Page 33
    Intel® Server Chassis H2000 Family TPS Power Sub-System below the Vfault threshold. Asserting the CR_BUS signal active low signal that turns on the +12V power rail. When this signal is not pulled low by the system, or left open, the outputs (except the +12VSB) turn off. This signal is pulled to a
  • Intel H2000WP | Technical Product Specification - Page 34
    Power Sub-System Intel® Server Chassis H2000 Family TPS Table 27. PSON# Signal Characteristics. sec 200msec 3.5.3 SMBAlert# Signal This signal indicates that the power supply is experiencing a problem that the user should investigate. This shall be asserted due to Critical events or Warning
  • Intel H2000WP | Technical Product Specification - Page 35
    Intel® Server Chassis H2000 Family TPS Power Sub-System Table 29. SMBAlert# Signal Characteristics Signal Type (Active Low) fall time Open collector/drain output from power supply. Pullup to VSB located in system. OK Power Alert to system MIN MAX 0 V 0.4 V 3.46 V 4 mA 50 A 100 s
  • Intel H2000WP | Technical Product Specification - Page 36
    Power Sub-System Intel® Server Chassis H2000 Family TPS 3.6.3 Over Thermal protection The power margin. 3.7 PMBus* The PMBus* features are requirements for power supply unit for use in server systems. This specification is based on the PMBus* specifications part I and II, revision 1.1. The
  • Intel H2000WP | Technical Product Specification - Page 37
    Intel® Server Chassis H2000 Family TPS Power Sub-System Table 32. PSU addressing PDB addressing Address0 Power supply PMBus* device 0 1 B0h B2h 3.7.2 Accuracy The 800 850 900 950 1000 Input power, W Figure 14. PMBus Monitoring Accuracy Revision 1.0 27 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 38
    server system does not support processor, which will most likely result in degraded performance as a result of throttling or thermal shutdown of the system. It is recommended to keep/apply the dummy plastic blocker(as shipped with HDD carrier) on any blank HDD carrier. 28 Revision 1.0 Intel
  • Intel H2000WP | Technical Product Specification - Page 39
    Intel® Server Chassis H2000 Family TPS Hard Disk Drive Support 5. Hard Disk Drive Support The server system provides two SKUs to support different types of Hard Disk Drives (HDD):  H2312xx : Supports 12x 3.5" HDD  H2216xx : Supports 16x 2.5" HDD 5.1 Hard Disk Drive Bays Scheme The server system
  • Intel H2000WP | Technical Product Specification - Page 40
    LEDs on the backplane to the carrier's face allowing it to be viewable from the front of the system. 5.3 Hot-Swap Hard Drive Support Both the Intel® Server Chassis H2312xx and H2216xx can support hot-swap SATA/SAS hard drives. Hard drives interface with the passive backplane through a blind mate
  • Intel H2000WP | Technical Product Specification - Page 41
    Intel® Server Chassis H2000 Family TPS Hard Disk Drive Support  H2312xxJR/KR: 12x SAS/SATA 3.5" HDDs at 6Gb the HDDs.  3.3V switcher regulator (from 12V) to power microcontroller, SAS/SATA re-drivers on the bridge board and various other components.  3.3V_AUX linear regulator (from 5V_AUX) for
  • Intel H2000WP | Technical Product Specification - Page 42
    Hard Disk Drive Support 5.3.2 Backplane Block Diagram Intel® Server Chassis H2000 Family TPS Figure 19. Passive Backplane Block Diagram (for one node D SATA/SAS connectors for Node 4 Figure 20. 3.5" Backplane Component and Connectors (Front View) 32 Revision 1.0 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 43
    Intel® Server Chassis H2000 Family TPS Hard Disk Drive Support A 20-pin Front Panel cable connector for Node 2, 4 B 2Blade Compute Node Power connector for Node 4 show the layout of major components and connectors for 2.5" Hot Swap backplane. Revision 1.0 33 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 44
    Hard Disk Drive Support Intel® Server Chassis H2000 Family TPS A SATA/SAS connectors for Node 1 B 4 Figure 23. 2.5" Backplane Component and Connectors (Back View) 5.3.5 Backplane LED Support The backplanes support both HDD online and activity/fault LEDs for each of the hard drive connectors.
  • Intel H2000WP | Technical Product Specification - Page 45
    Intel® Server Chassis H2000 Family TPS Hard Disk Drive Support Figure 24. Hard Drive Carrier LED General HDD LED functionality is displayed below: Table 34 GND 4 P12V 3 GND 6 P12V 5 GND 8 P12V 7 GND 10 P12V 9 GND 12 P12V 11 GND Revision 1.0 35 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 46
    Hard Disk Drive Support Intel® Server Chassis H2000 Family TPS Pin Signal Description Pin Signal Description 14 P12V 13 GND 16 P12V 15 GND 18 P12V 17 CLK 32 FP ID BTN_N 33 GND 34 FP RST BTN_N 35 SMBUS_R7 DATA 36 FP PWR BTN_N 36 Revision 1.0 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 47
    Intel® Server Chassis H2000 Family TPS Hard Disk Drive Support Pin Signal Description 37 SMBUS_R7 CLK 39 GND 41 PMBUS Alert_N 10 FP1_ID_LED_N 11 GND 12 FP2_PWR_BTN_N 13 FP2_RST_BTN_N 14 FP2_ID_BTN_N 15 P3V3SB 16 FP2_PWR_LED_N Revision 1.0 37 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 48
    Hard Disk Drive Support Intel® Server Chassis H2000 Family TPS Pin Signal Description 17 FP2_HEALTH_LEDG_N 18 FP2_HEALTH_LEDA_N 19 FP2_ACTIVITY_LED_N 20 Signal Description A0 PSON_N 12V RS_RTN 12V RS PDU1-12VSB PDU2-12VSB Reserved 38 Revision 1.0 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 49
    Family TPS 6. Front Panel Control and Indicators The Intel® Server Chassis H2000 family Front Control Panel is integrated is pre-assembled and fixed with the rack handles. A System Power Button with LED B System ID LED Button C System Status LED D Network Link/Activity LED Figure 25. Front
  • Intel H2000WP | Technical Product Specification - Page 50
    Intel® Server Chassis H2000 Family TPS Front Panel Control and Indicators 6.1 Control Panel Button The following table lists the control panel features and functions. The control panels features a system power button. Table 41. Front Control Button Function Feature Power Button with Power LED
  • Intel H2000WP | Technical Product Specification - Page 51
    Front Panel Control and Indicators Intel® Server Chassis H2000 Family TPS 6.2.1 Power/Sleep LED Table 43. Power LED Operation State Power Off Power On Power Mode Non-ACPI Non-ACPI LED Off Solid On S5 ACPI Off S1 Sleep ACPI Blink S0 ACPI Solid On Description System power is off and the
  • Intel H2000WP | Technical Product Specification - Page 52
    Intel® Server Chassis H2000 Family TPS Front Panel Control and Indicators Color State Criticality Amber Solid on Critical, nonrecoverable 2. VRD Hot asserted. Description 3. One of the redundant power supplies failed. 4. Minimum number of fans to cool the system are not present or have
  • Intel H2000WP | Technical Product Specification - Page 53
    remove AC power from the system prior to opening the chassis for service You can download the latest system documentation, drivers, and system software from the Intel® Support website at http://www.intel.com/p/en_US/support/highlights/server/H2000JF. Revision 1.0 43 Intel order number: G59059-001
  • Intel H2000WP | Technical Product Specification - Page 54
    Processor Advanced Programmable Interrupt Control Application Specific Integrated Circuit Advanced Server Management Interface Basic Input/Output System Controller Hertz (1 cycle/second) Inter-Integrated Circuit Bus Intel® Architecture Input Buffer I/O Controller Hub Intelligent Chassis Management
  • Intel H2000WP | Technical Product Specification - Page 55
    Memory Reliability, Availability, Serviceability, Usability, and Manageability Reduced Instruction Set Computing Remote Management the server board.) Sensor Data Record Single Edge Connector Cartridge Serial Electrically Erasable Programmable Read-Only Memory Revision 1.0 45 Intel order
  • Intel H2000WP | Technical Product Specification - Page 56
    Intel® Server Chassis H2000 Family TPS Glossary Term SEL SIO SMI SMM SMS SNMP SSI TBD TIM UART UDP UHCI UTC VID VRD Word ZIF System Event Log Definition Server Input/Output Server Management Interrupt (SMI is the highest priority non-maskable interrupt.) Server Management Mode Server
  • Intel H2000WP | Technical Product Specification - Page 57
    Node Manager 1.5 External Interface Specification using IPMI, 2007. Intel Corporation.  Node Power and Thermal Management Architecture Specification v1.5, rev.0.79. 2007, Intel Corporation.  Intel® Server System Integrated Baseboard Management Controller Core External Product Specification, 2007
  • Intel H2000WP | Technical Product Specification - Page 58
    Chassis H2000 Family TPS Reference Documents  Intel® Thurley Server Platform Services IPMI Commands Specification, 2007. Intel Corporation.  Intel® Server Safety and Regulatory, 2011. Intel Corporation. (Intel Order Code: G23122)  Intelligent Platform Management Bus Communications Protocol
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

Intel
®
Server Chassis H2000 Family
Technical Product Specification
Intel order number: G59059-001
Revision 1.0
February, 2012
Enterprise Platforms and Services Division