Intel H2000WP Technical Product Specification - Page 37
PMBus Monitoring Accuracy
View all Intel H2000WP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Intel® Server Chassis H2000 Family TPS Power Sub-System Table 32. PSU addressing PDB addressing Address0 Power supply PMBus* device 0 1 B0h B2h 3.7.2 Accuracy The sensor commands shall meet the following accuracy requirements. The accuracies shall be met over the specified ambient temperature and the full range of rated input voltage. Table 33. PMBus Accuracy Output Loading READ_PIN and READ_EIN READ_FAN READ_IOUT READ_TEMPERATURE 10% - 20% > 20% - 50% > 50% - 100% See graphs below +/-500 RPM +/-5% +/-2% +/-2% +/- 3ºC Accuracy, +/-% Accuracy, +/- W PMBus Input power monitoring accuracy 6.0% Accuracy, +/-W Accuracy, +/-% 25 5.0% 20 4.0% 15 3.0% 10 2.0% 5 1.0% 0.0% 0 37.5 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Input power, W Figure 14. PMBus Monitoring Accuracy Revision 1.0 27 Intel order number: G59059-001