Intel H2000WP Technical Product Specification - Page 51
Power/Sleep LED, System Status LED
View all Intel H2000WP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
Front Panel Control and Indicators Intel® Server Chassis H2000 Family TPS 6.2.1 Power/Sleep LED Table 43. Power LED Operation State Power Off Power On Power Mode Non-ACPI Non-ACPI LED Off Solid On S5 ACPI Off S1 Sleep ACPI Blink S0 ACPI Solid On Description System power is off and the BIOS has not initialized the chipset. System power is on but the BIOS has not yet initialized the chipset. Mechanical is off and the operating system has not saved any context to the hard disk. DC power is still on. The operating system has saved context and gone into a level of low-power state. System and the operating system are up and running. Note: Blink rate is ~ 1Hz at 50% duty cycle. 6.2.2 System Status LED Table 44. System Status LED Operation Color State Off N/A Criticality Not ready Green/ Both Solid Amber On Not ready Green Green Solid on Blink Ok Degraded Amber Blink Non-critical Description Power off or BMC initialization completes if no degraded, noncritical, critical, or non-recoverable conditions exist after power cable plug in. Pre DC Power On - 15-20 second BMC Initialization when AC is applied to the server. The system will not POST until BMC initialization completes. System ready BIOS detected 1. Unable to use all of the installed memory (more than one DIMM installed).1 2. In a mirrored configuration, when memory mirroring takes place and system loses memory redundancy. This is not covered by (2). 1 3. PCI Express* correctable link errors. 4. Integrated BMC detected 5. One of redundant power supplies not present. 6. CPU disabled - if there are two CPUs and one CPU is disabled. 7. Fan alarm - Fan failure. Number of operational fans should be more than minimum number needed to cool the system. 8. Non-critical threshold crossed - Temperature, voltage, power nozzle, power gauge, and PROCHOT2 (Therm Ctrl) sensors. 9. Battery failure. 10. Predictive failure when the system has redundant power supplies. Non-fatal alarm - system is likely to fail BIOS Detected 1. In non-mirroring mode, if the threshold of ten correctable errors is crossed within the window.1 2. PCI Express* uncorrectable link errors. Integrated BMC Detected 1. Critical threshold crossed - Voltage, temperature, power nozzle, power gauge, and PROCHOT (Therm Ctrl) sensors. Revision 1.0 41 Intel order number: G59059-001