Invacare XLT Owners Manual - Page 49
Replacing the Crank Arms - XLT Gold, XLT PRO and, Top End Force
View all Invacare XLT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
SECTION 8-SERVICE PROCEDURES Replacing the Crank Arms - XLT Gold, XLT PRO and Top End Force NOTE: For this procedure, refer to FIGURE 8.2 on page 50. NOTE: Right and left determined from as if seated on the handcycle. Replacing the Left Side Crank Arms 1. Remove the two socket screws from the existing crank arm clamp. 2. Remove socket screw and cap from the spindle. 3. Remove the existing crank arm from the spindle. 4. Position the new crank arm onto the spindle so that the new crank arm is evenly aligned with the right side crank arm. 5. Re install the socket screw and cap from the spindle. DO NOT over tighten. 6. Using the two socket screws, secure the new crank arm clamp to the spindle. Securely tighten. Replacing the Right Side Crank Arms 1. Remove the two mounting bolts and locknuts securing the chain ring disk to the tabs of the existing crank arm. 2. Remove the two socket screws from the existing crank arm clamp. 3. Remove socket screw and cap from the spindle. 4. Remove the existing crank arm from the spindle. 5. Position the new crank arm onto the spindle. 6. Using the two mounting bolts and locknuts, secure the tabs of the new crank arm to the chain ring disk. 7. Ensure the new crank arm is evenly aligned with the left side crank arm. 8. Re install the socket screw and cap from the spindle. DO NOT over tighten. 9. Using the two socket screws, secure the new crank arm clamp to the spindle. Securely tighten. Part No 1114850 49 Recumbent Handcycle Series