JVC HD100 Instructions - Page 48

RS-232C Communication Examples, This shows the communication examples of RS-232C.

Page 48 highlights

6 Others RS-232C Communication Examples This section shows the communication examples of RS-232C. „ Operating command Type Connection check Power (On) Power (Off) Input (COMP.) Remote Control (MENU) Gamma table (Custom) Gamma coefficient (1.8) Gamma data (R) Test pattern (Staircase) Command PC  This unit: 21 89 01 00 00 0A This unit  PC: 06 89 01 00 00 0A PC  This unit: 21 89 01 50 57 31 0A This unit  PC: 06 89 01 50 57 0A PC  This unit: 21 89 01 50 57 30 0A This unit  PC: 06 89 01 50 57 0A PC  This unit: 21 89 01 49 50 32 0A This unit  PC: 06 89 01 49 50 0A PC  This unit: 21 89 01 52 43 37 33 32 45 0A This unit  PC: 06 89 01 52 43 0A PC  This unit: 21 89 01 47 54 34 0A This unit  PC: 06 89 01 47 54 0A PC  This unit: 21 89 01 47 50 30 0A This unit  PC: 06 89 01 47 50 0A PC  This unit: 21 89 01 47 52 0A This unit  PC: 06 89 01 47 52 0A PC  This unit: 512 bytes of gamma data This unit  PC: 06 89 01 47 52 0A PC  This unit: 21 89 01 54 53 36 0A This unit  PC: 06 89 01 54 53 0A Description Checks connection When power is turned on from standby mode When power is turned off (standby mode) from power-on mode When video input is set to component When the same operation as pressing the [MENU] button on the remote control is made When switched to "Custom" When set to "1.8" When the red gamma data is set When staircase (gray) is set 48

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

6
48
Others
This section shows the communication examples of RS-232C.
Operating command
RS-232C Communication Examples
Type
Command
Description
Connection check
PC
This unit: 21 89 01 00 00 0A
This unit
PC: 06 89 01 00 00 0A
Checks connection
Power (On)
PC
This unit: 21 89 01 50 57 31 0A
This unit
PC: 06 89 01 50 57 0A
When power is turned on from standby mode
Power (Off)
PC
This unit: 21 89 01 50 57 30 0A
This unit
PC: 06 89 01 50 57 0A
When power is turned off (standby mode)
from power-on mode
Input (COMP.)
PC
This unit: 21 89 01 49 50 32 0A
This unit
PC: 06 89 01 49 50 0A
When video input is set to component
Remote Control
(MENU)
PC
This unit: 21 89 01 52 43 37 33 32 45 0A
This unit
PC: 06 89 01 52 43 0A
When the same operation as pressing the
[MENU] button on the remote control is made
Gamma table
(Custom)
PC
This unit: 21 89 01 47 54 34 0A
This unit
PC: 06 89 01 47 54 0A
When switched to “Custom”
Gamma coefficient
(1.8)
PC
This unit: 21 89 01 47 50 30 0A
This unit
PC: 06 89 01 47 50 0A
When set to “1.8”
Gamma data
(R)
PC
This unit: 21 89 01 47 52 0A
This unit
PC: 06 89 01 47 52 0A
PC
This unit: 512 bytes of gamma data
This unit
PC: 06 89 01 47 52 0A
When the red gamma data is set
Test pattern
(Staircase)
PC
This unit: 21 89 01 54 53 36 0A
This unit
PC: 06 89 01 54 53 0A
When staircase (gray) is set