Mounting this Unit, Precautions for Mounting

Page 51 highlights

Getting Started Preparation Basic Operation ENGLISH Mounting this Unit Measures to prevent the unit from toppling or dropping should be taken for safety reasons and accident prevention during emergencies including earthquakes. When mounting this unit on a pedestal or ceiling, remove the 4 feet on the bottom surface and use all the 4 screw holes (M5 screws) to mount. Ceiling „ Bottom Surface 4 locations Air inlets Precautions for Mounting ... z Special expertise and techniques are required for z Regardless whether the unit is still under guarantee, JVC mounting this unit. Be sure to ask your dealer or a is not liable for any product damage caused by mounting specialist to perform mounting. the unit with non-JVC ceiling fittings or when the z Depth of the screw holes (screw length) is 30 mm. Use screws shorter than 30 mm but longer than 19 mm. environment is not suitable for ceiling-mount. z When using the unit hanging from a ceiling, pay attention Using other screws will result in malfunctioning or cause the unit to drop. to the surrounding temperature. When a heater is in use, temperature around the ceiling is higher than expected. z When mounting to a pedestal, ensure sufficient space (foot height of 21.5 mm or higher) around the unit so that the air inlets are not blocked. z Do not tilt this unit more than ±5 degrees from side to side when using. This may result in uneven colors or shortening of lamp life. Settings Troubleshooting Others 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

51
ENGLISH
Getting Started
Preparation
Basic Operation
Settings
Troubleshooting
Others
Measures to prevent the unit from toppling or dropping should be taken for safety reasons and accident prevention
during emergencies including earthquakes.
When mounting this unit on a pedestal or ceiling, remove the 4 feet on the bottom surface and use all the 4 screw
holes (M5 screws) to mount.
.........................................................................................................
Precautions for Mounting
Special expertise and techniques are required for
mounting this unit. Be sure to ask your dealer or a
specialist to perform mounting.
Depth of the screw holes (screw length) is 30 mm. Use
screws shorter than 30 mm but longer than 19 mm.
Using other screws will result in malfunctioning or
cause the unit to drop.
When mounting to a pedestal, ensure sufficient space
(foot height of 21.5 mm or higher) around the unit so that
the air inlets are not blocked.
Do not tilt this unit more than ±5 degrees from side to side
when using. This may result in uneven colors or shortening
of lamp life.
Regardless whether the unit is still under guarantee, JVC
is not liable for any product damage caused by mounting
the unit with non-JVC ceiling fittings or when the
environment is not suitable for ceiling-mount.
When using the unit hanging from a ceiling, pay attention
to the surrounding temperature. When a heater is in use,
temperature around the ceiling is higher than expected.
Mounting this Unit
Ceiling
Air inlets
4 locations
Bottom Surface