JVC KY-F1030U KY-F1030U digital camera 52 page instruction manual (550KB, PDF) - Page 25

Settings and adjustments for shooting

Page 25 highlights

3. Settings and adjustments for shooting Lens settings Set according to whether the used lens to be used is an auto-iris lens or a manual lens. Set the used Lens (Default setting: AUTO) Set the [IRIS MODE] on the [EXPOSURE] screen. (੬ page E33) AUTO : Setting when auto-iris lens is used in auto mode. MANUAL : Set when using a manual lens, using an auto-iris lens in MANUAL or no lens. * If the auto-iris lens cable is not connected to the [LENS] connector, the setting automatically becomes "MANUAL". Monitor adjustment The colour contrast and brightness are adjusted whilst, built-in test signals of the camera are being displayed on the PC monitor. [ANALOG OUT] [IEEE1394] ANALOG OUT IEEE1394 LENS DC IN POWER MD CONTROL REMOTE SEE INSTRUCTION MANUAL 1. Connect the [ANALOG OUT] connector or the [IEEE1394] connector to the PC. 2. Set the function setting switch NO.1 on the switch panel on the side of the KY-F1030 to "ON". ON OFF 1 23 4 3. Turn ON the KY-F1030, and then start the PC. * When connecting through the [IEEE1394] connector, power is supplied from the PC. Inside window UP/AW MENU SET DOWN 1 2 34 Default Setting Switch 4. Adjust the monitor. MEMO • For how to adjust, see the instructions for the employed monitor. • The peak level of the test signal is set to 0.7V from the fac- tory. To use 0.57V, change the setting by [TEST PATTERN] ➝ [LEVEL] on the [SYSTEM SETTING] screen. ੬ page E40 TEST PATTERN E21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

E21
Lens settings
3. Settings and adjustments for shooting
Set according to whether the used lens to be used is an auto-iris lens or a manual lens.
Set the [IRIS MODE] on the [EXPOSURE] screen.
(
±
page E33)
AUTO
: Setting when auto-iris lens is used in auto mode.
MANUAL : Set when using a manual lens, using an auto-iris
lens in MANUAL or no lens.
* If the auto-iris lens cable is not connected to
the [LENS] connector, the setting automatically
becomes “MANUAL”.
(Default setting: AUTO)
Monitor adjustment
ON
OFF
1
234
The colour contrast and brightness are adjusted whilst, built-in test signals of the camera are
being displayed on the PC monitor.
1.
Connect the [ANALOG OUT] connector or the
[IEEE1394] connector to the PC.
2.
Set the function setting switch NO.1 on the switch panel
on the side of the KY-F1030 to “ON”.
3.
Turn ON the KY-F1030, and then start the PC.
* When connecting through the [IEEE1394] connector,
power is supplied from the PC.
4.
Adjust the monitor.
MEMO
For how to adjust, see the instructions for the employed
monitor.
The peak level of the test signal is set to 0.7V from the fac-
tory. To use 0.57V, change the setting by [TEST PATTERN]
[LEVEL] on the [SYSTEM SETTING] screen.
±
page E40 TEST PATTERN
Set the used Lens
UP/AW
SET
MENU
DOWN
1 2 34
ANALOG OUT
IEEE1394
LENS
MD
CONTROL
REMOTE
DC IN
POWER
SEE INSTRUCTION MANUAL
[ANALOG OUT]
[IEEE1394]
Inside window
Default Setting Switch