Konica Minolta AccurioPress 6120 AccurioPress 6136/6136P/6120 Daily Maintenanc - Page 29
Regular adjustment flow, 2.3.1 Adjustment Timing, 2.3.2 Adjustment Order
View all Konica Minolta AccurioPress 6120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
2.3 Regular adjustment flow 2 2.3 Regular adjustment flow 2.3.1 Adjustment Timing When you have changed paper (brand, weight, or size) in a tray Tips - If you do not change paper in a tray for one or more days, make adjustments before outputting a job (before the adjustment flow for each job). 2.3.2 Adjustment Order - With scanner (Original Glass) mounted Adjustment order 1 2 3 Adjustment item Finely adjust the side guide plates of the paper tray (for PF-710) [Front] Adjustment [Scan Meas.] Adjustment Reference page 2-7 page 2-11 page 2-16 - Without scanner (Original Glass) mounted Adjustment order 1 2 3-a 3-b Adjustment item Reference Finely adjust the side guide plates of the paper tray (for PF-710) [Front] Adjustment [Rotate/Skew] Adjustment: Prioritizes the accuracy of the image position. [Gap] Adjustment (Back side adjustment): Reduces adjustment items required to make simple adjustments. page 2-7 page 2-11 page 2-24 page 2-27 - With Intelligent Quality Optimizer IQ-501 mounted Adjustment order 1 2 Adjustment item Finely adjust the side guide plates of the paper tray (for PF-710) [AutoMeasure] Adjustment Reference page 2-7 page 2-32 AccurioPress 6136/6136P/6120 2-4