Konica Minolta AccurioPress 6120 AccurioPress 6136/6136P/6120 Daily Maintenanc - Page 39
Press the number of each point, and use the touch panel keypad to enter the measured length.
View all Konica Minolta AccurioPress 6120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
2.5 How to Operate the Both Sides Adj. Item 2 11 Check the lengths at points [2], [4], [6], and [8] on the second and third output charts. Be sure to make note of the measurement lengths. When the lengths at points [2], [4], [6], and [8] are within the respective ranges shown below, press [Close], then press [OK] to finish the adjustment. When the lengths at points [2], [4], [6], and [8] are outside the respective ranges shown below, also measure the lengths at points [1], [3], [5], and [7], then proceed to step 12. [2]: 200 mm ^ 0.3 mm [4]: 200 mm ^ 0.3 mm [6]: 200 mm ^ 0.3 mm [8]: 200 mm ^ 0.3 mm 12 Press the number of each point, and use the touch panel keypad to enter the measured length. Press [Clear] to reset the value. AccurioPress 6136/6136P/6120 2-14