Konica Minolta AccurioPress 6120 AccurioPress 6136/6136P/6120 Daily Maintenanc - Page 73
Regular adjustment flow (High accuracy), 3.3.1 Adjustment Timing, 3.3.2 Adjustment Order
View all Konica Minolta AccurioPress 6120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
3.3 Regular adjustment flow (High accuracy) 3 3.3 Regular adjustment flow (High accuracy) 3.3.1 Adjustment Timing - Just before outputting a job based on the strict density standard - When the density stability is not desirable (you want to increase the accuracy of reproducibility) - When the paper type is different 3.3.2 Adjustment Order - When an RU optional unit (Relay Unit RU-518) is not mounted Adjustment order 1 2 Adjustment item [Gamma Automatic Adjustment] [Maximum Density Adjustment] Reference page 3-9 page 3-39 - When an RU optional unit (Relay Unit RU-518) is mounted Adjustment order 1 2 3 4 Adjustment item Color Density Control setting check [Gamma Automatic Adjustment] [Max. Density Auto Adj.] [Color density manual control] Reference page 3-41 page 3-9 page 3-39 page 3-43 Tips - If you use [Package Color Auto Adj.], this machine automatically makes the adjustments in step 2 below and after. To use [Package Color Auto Adj.], mount Intelligent Quality Optimizer IQ-501 on the machine. For details, refer to page 3-46. - For "Color Density Control setting check", check that [Default] or [Registered Adj. Data] is also selected for the tray in [Paper Setting] - [Color Density Control]. - To use general paper, select [Default Adj. Data]. To use special paper or increase the accuracy of the automatic adjustment, [Each Paper Type Color Adj.] is recommended. AccurioPress 6136/6136P/6120 3-4