Konica Minolta AccurioPress 6120 AccurioPress 6136/6136P/6120 Daily Maintenanc - Page 41

[Scan Meas.] Adjustment, How to Operate the Both Sides Adj. Item, Original Glass

Page 41 highlights

2.5 How to Operate the Both Sides Adj. Item 2 2.5.3 [Scan Meas.] Adjustment Adjust the magnification ratio and printing position of the back side with reference to the printing position of the front side. The magnification ratio and printing position of the back side are automatically adjusted by using the scanner of this machine to measure the gap amount in printing position of the back side to the front side. You do not need to measure the gap amount with a scale. The adjustment is available for paper of all sizes which can be used with this machine. Print out 1 to 20 sheets of the adjustment chart having both front and back sides printed, and scan them 4 times per sheet. The average value of gap amounts in printing position of the back side to the front side, which can be obtained by scanning up to 20 sheets of the adjustment chart, will be calculated in order to adjust the magnification ratio and printing position of the back side. Tips - The [Scan Meas.] adjustment for scanning adjustment charts is not available on a machine that is not equipped with the scanner (Original Glass). - The [Scan Meas.] adjustment provides the coordination based on the average value of gap amounts, taking into account the gap in printing position between the first and last sheets which can be produced when multiple sheets are output. - Performing the [Scan Meas.] adjustment may require readjustment of [Zoom]/[Image Shift] adjustment registered in a paper profile. - The [Scan Meas.] adjustment is a simple method to adjust only the magnification ratio and image position of the back side. To make adjustments including the front side, perform [AutoMeasure] adjustment, [Chart Adjustment], or [Zoom]/[Image Shift] adjustment. 1 Press [Both Sides] on the [MACHINE] screen. The [Scan Meas.] screen is displayed. If the [Scan Meas.] screen is not displayed, press the [Scan Meas.] tab on the screen. AccurioPress 6136/6136P/6120 2-16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

2.5
How to Operate the Both Sides Adj. Item
2
AccurioPress 6136/6136P/6120
2-16
2.5.3
[Scan Meas.] Adjustment
Adjust the magnification ratio and printing position of the back side with reference to the printing position of
the front side. The magnification ratio and printing position of the back side are automatically adjusted by
using the scanner of this machine to measure the gap amount in printing position of the back side to the front
side. You do not need to measure the gap amount with a scale. The adjustment is available for paper of all
sizes which can be used with this machine.
Print out 1 to 20 sheets of the adjustment chart having both front and back sides printed, and scan them
4 times per sheet. The average value of gap amounts in printing position of the back side to the front side,
which can be obtained by scanning up to 20 sheets of the adjustment chart, will be calculated in order to
adjust the magnification ratio and printing position of the back side.
Tips
-
The [Scan Meas.] adjustment for scanning adjustment charts is not available on a machine that is not
equipped with the scanner (
Original Glass
).
-
The [Scan Meas.] adjustment provides the coordination based on the average value of gap amounts,
taking into account the gap in printing position between the first and last sheets which can be produced
when multiple sheets are output.
-
Performing the [Scan Meas.] adjustment may require readjustment of [Zoom]/[Image Shift] adjustment
registered in a paper profile.
-
The [Scan Meas.] adjustment is a simple method to adjust only the magnification ratio and image posi-
tion of the back side. To make adjustments including the front side, perform [AutoMeasure] adjustment,
[Chart Adjustment], or [Zoom]/[Image Shift] adjustment.
1
Press [Both Sides] on the [MACHINE] screen.
The [Scan Meas.] screen is displayed. If the [Scan Meas.] screen is not displayed, press the [Scan
Meas.] tab on the screen.