Konica Minolta AccurioPress 6120 AccurioPress 6136/6136P/6120 Daily Maintenanc - Page 49
[Rotate/Skew] Adjustment
View all Konica Minolta AccurioPress 6120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
2.5 How to Operate the Both Sides Adj. Item 2 poorly adjusted, or the adjustments of the reference positions are not completed. Confirm these points before restarting the scan measurement. 10 Press [Close]. 2.5.4 [Rotate/Skew] Adjustment If the entire image is rotated horizontally or skewed in the diagonal direction, adjust [Rotate/Skew]. This adjustment is available for the front side and back side. In [Rotate/Skew], the adjustment values are automatically entered when the following adjustment is performed. (The adjustment value is entered in both [Front] and [Back].) - [Rotate/Skew] - [Chart Adjustment] - [Back] - [Chart Adjustment] - [Scan Meas.] adjustment The adjustment values are reflected on the [Rotate/Skew] screen. If necessary, you can adjust them manually. To manually adjust [Rotate/Skew], follow the steps below. The adjustment values specified in [Rotate/Skew] are retained for each tray. If the paper size in the tray is changed, adjust [Rotate/Skew] again to fit the new paper size. Tips - If [UTILITY] - [User Setting] - [Common Setting] - [Both Sides Rotate/Skew] ([UTILITY] - [Administrator Setting] - [Common Setting] - [Both Sides Rotate/Skew]) is set to [Disable], the [Rotate/Skew] adjustment is not available. To perform the [Rotate/Skew] adjustment, set [Both Sides Rotate/Skew] to [Enable]. AccurioPress 6136/6136P/6120 2-24