Konica Minolta AccurioPress 6120 AccurioPress 6136/6136P/6120 Daily Maintenanc - Page 48

After pressing [Yes], output a sheet of the adjustment chart to confirm the result. If readjustment is

Page 48 highlights

2.5 How to Operate the Both Sides Adj. Item 2 Fourth time: Set the back side of the adjustment chart face up (turned away from the original glass), with its bottom edge positioned to the back side. % When four times of scanning are completed, a dialog is displayed to calculate the adjustment value. 9 Select whether to continue the scan measurement or to finish the scan measurement and calculate the adjustment value. To continue the scan measurement, press [No]. To finish the scan measurement and calculate the adjustment value, press [Yes]. % Pressing [No] returns to the [Scan Adjustment Chart] screen on which the counter of [Chart Sheets] is added by one. Repeat steps 6 to 8 for the number of adjustment charts. The measurement results will be added up. This operation can be repeated up to 20 times. % Pressing [Yes] automatically calculates the adjustment value from the added measurement results and reflects it on [Zoom] and [Image Shift] or [Rotate/Skew] to be specified for [Back]. [Rotate/Skew] may be reflected to both of [Front] and [Back]. After pressing [Yes], output a sheet of the adjustment chart to confirm the result. If readjustment is needed, repeat steps 4 to 9. % If the adjustment value calculated by pressing [Yes] exceeds the adjustment range, the following dialog is displayed. Press [Close] to discard the measurement results, and restart the scan measurement from the beginning. Possible causes to exceed the adjustment range may include that the chart used in the scan measurement is incorrect (a different chart has been used), the printing position of the front side has been AccurioPress 6136/6136P/6120 2-23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

AccurioPress 6136/6136P/6120
2-23
2.5
How to Operate the Both Sides Adj. Item
2
Fourth time: Set the back side of the adjustment chart face up (turned away from the
original glass
),
with its bottom edge positioned to the back side.
%
When four times of scanning are completed, a dialog is displayed to calculate the adjustment value.
9
Select whether to continue the scan measurement or to finish the scan measurement and calculate the
adjustment value.
To continue the scan measurement, press [No].
To finish the scan measurement and calculate the adjustment value, press [Yes].
%
Pressing [No] returns to the [Scan Adjustment Chart] screen on which the counter of [Chart Sheets]
is added by one. Repeat steps 6 to 8 for the number of adjustment charts. The measurement results
will be added up. This operation can be repeated up to 20 times.
%
Pressing [Yes] automatically calculates the adjustment value from the added measurement results
and reflects it on [Zoom] and [Image Shift] or [Rotate/Skew] to be specified for [Back].
[Rotate/Skew] may be reflected to both of [Front] and [Back].
After pressing [Yes], output a sheet of the adjustment chart to confirm the result. If readjustment is
needed, repeat steps 4 to 9.
%
If the adjustment value calculated by pressing [Yes] exceeds the adjustment range, the following
dialog is displayed. Press [Close] to discard the measurement results, and restart the scan meas-
urement from the beginning.
Possible causes to exceed the adjustment range may include that the chart used in the scan meas-
urement is incorrect (a different chart has been used), the printing position of the front side has been