Konica Minolta Kodak i620 User Guide - Page 46

Reinstall the upper and lower imaging guides. Handle the imaging, Close the pod.

Page 46 highlights

23. Carefully vacuum the areas between the lamps (both upper and lower), then use a Staticide wipe to thoroughly clean the glass dust plate between the lamps. 24. Clean the imaging guides thoroughly with a Staticide wipe. IMPORTANT: Staticide wipes contain isopropanol which can cause eye irritation and dry skin. Wash your hands with soap and water after performing maintenance procedures. Refer to the MSDS for more information. 25. Reinstall the upper and lower imaging guides. Handle the imaging guides carefully as to not put fingerprints on the guides. 26. Close the pod. 27. Reinstall the output tray. 5-10 28. Power on the scanner. A-61500 April 2007

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

5-10
A-61500
April 2007
23.Carefully vacuum the areas between the lamps (both upper and
lower), then use a Staticide wipe to thoroughly clean the glass dust
plate between the lamps.
24.Clean the imaging guides thoroughly with a Staticide wipe.
IMPORTANT: Staticide wipes contain isopropanol which can cause eye
irritation and dry skin. Wash your hands with soap and
water after performing maintenance procedures. Refer to
the MSDS for more information.
25.Reinstall the upper and lower imaging guides. Handle the imaging
guides carefully as to not put fingerprints on the guides.
26.Close the pod.
27.Reinstall the output tray.
28.Power on the scanner.