Konica Minolta Kodak i620 User Guide - Page 61

Operator Log Message, Description/Action, Display only, Maintenance, Informational message.

Page 61 highlights

Operator Log Message Multi-feed detected Multi-feed detected Multi-feed length detected Multi-feed length detected No paper in elevator tray Page on demand complete Parameter settings conflicting Pod door closed Pod door opened Power on self-test completed ID# Description/Action 23 A multi-feed document condition has been detected and the scanner was set to the Display only mode. • Check the host monitor to see if there are any overlapped documents that may need to be rescanned. This condition may be caused by poor document separation. • Replace the separation roller tires and pre-separation pad. See Chapter 5, Maintenance for procedures. 334 A multi-feed has been detected, the transport has stopped and the job has ended. • Re-enable the scanner. Check the host monitor to see if there are any overlapped documents that may need to be rescanned. This condition may be caused by poor document separation. • Replace the separation roller tires and pre-separation pad. See Chapter 5, Maintenance for procedures. 247 A document was measured which exceeded the configured maximum allowable length in the Display only mode. This may be due to a document overlap. • Check the host monitor to see if there are any overlapped documents that may need to be rescanned. This condition may be caused by poor document separation. • Replace the separation roller tires and pre-separation pad. See Chapter 5, Maintenance for procedures. 248 A document was measured which exceeded the configured maximum allowable length and the transport has stopped. This may be due to a document overlap. • Re-enable the scanner. Check the host monitor to see if there are any overlapped documents that may need to be rescanned. This condition may be caused by poor document separation. • Replace the separation roller tires and pre-separation pad. See Chapter 5, Maintenance for procedures. 260 The scanner was started with an empty elevator tray. • Place the documents you want to scan in the elevator tray and try again. 337 Informational message. The scanner has completed scanning the requested number of documents. 4 The image processing values sent by the host are invalid. • Check the job settings for illegal combinations. Refer to the Image Processing Guide for valid parameter values. 213 Informational message. The pod was closed. 212 Informational message. The pod is not closed completely. 20 Informational message. The scanner has completed its self-tests after power-on. 6-8 A-61500 April 2007

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

6-8
A-61500
April 2007
Operator Log Message
ID#
Description/Action
Multi-feed detected
23
A multi-feed document condition has been detected and the
scanner was set to the
Display only
mode.
• Check the host monitor to see if there are any overlapped
documents that may need to be rescanned.
This condition may be caused by poor document separation.
• Replace the separation roller tires and pre-separation pad.
See Chapter 5,
Maintenance
for procedures.
Multi-feed detected
334
A multi-feed has been detected, the transport has stopped and
the job has ended.
• Re-enable the scanner. Check the host monitor to see if there
are any overlapped documents that may need to be
rescanned.
This condition may be caused by poor document separation.
• Replace the separation roller tires and pre-separation pad.
See Chapter 5,
Maintenance
for procedures.
Multi-feed length detected
247
A document was measured which exceeded the configured
maximum allowable length in the
Display only
mode. This may
be due to a document overlap.
• Check the host monitor to see if there are any overlapped
documents that may need to be rescanned.
This condition may be caused by poor document separation.
• Replace the separation roller tires and pre-separation pad.
See Chapter 5,
Maintenance
for procedures.
Multi-feed length detected
248
A document was measured which exceeded the configured
maximum allowable length and the transport has stopped. This
may be due to a document overlap.
• Re-enable the scanner. Check the host monitor to see if there
are any overlapped documents that may need to be
rescanned.
This condition may be caused by poor document separation.
• Replace the separation roller tires and pre-separation pad.
See Chapter 5,
Maintenance
for procedures.
No paper in elevator tray
260
The scanner was started with an empty elevator tray.
• Place the documents you want to scan in the elevator tray and
try again.
Page on demand complete
337
Informational message.
The scanner has completed scanning
the requested number of documents.
Parameter settings conflicting
4
The image processing values sent by the host are invalid.
• Check the job settings for illegal combinations. Refer to the
Image Processing Guide
for valid parameter values.
Pod door closed
213
Informational message.
The pod was closed.
Pod door opened
212
Informational message
. The pod is not closed completely.
Power on self-test completed
20
Informational message.
The scanner has completed its self-tests