Konica Minolta Kodak i620 User Guide - Page 59
Message listing, Operator Log Message, Description/Action
View all Konica Minolta Kodak i620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Message listing Following is an alphabetic list of messages and corrective actions you can take if one of the following messages is encountered. Operator Log Message Background accessory changed while powered up Calibration failed Calibration is suggested Calibration succeeded Calibration target is too narrow Call Service Check document preparation Check imaging guides and lamps Close pod and re-enable scanner Document too dark to deskew Document too long to rotate Elevator too full, feed module missing or broken ID# Description/Action 381 Background Accessory was changed while the scanner was powered on. • Turn the power off to the scanner, wait a few seconds and power the scanner back on. • If you get this message and you did not change the Background Accessory, clean and calibrate the scanner. 108 • Try to calibrate the scanner again. Be sure you are using the correct calibration target. See Chapter 3, "Calibrating the scanner". • Clean the imaging guides. See Chapter 5, Maintenance for procedures. • If the problem persists, call Service. 185, 585, • It is suggested that you calibrate the scanner when the current 985 batch of documents has completed. 107 Informational message. The scanner has been successfully calibrated. 331 The calibration target is too small. A 12- x 12-inch calibration target is required for Image calibration. • Calibrate the scanner again using the correct calibration target. Many ID numbers A condition was detected that may require repair. • Turn the power off to the scanner, wait a few seconds and power the scanner back on. • If the problem persists, call Service. 123 • Make sure the leading edges of the documents are aligned. See Chapter 3, "Document preparation" for more information. 149, 549, • Verify that the imaging guides are installed correctly. See 949 Chapter 5, Maintenance. • Clean both sides of the imaging guides. • If the pod is closed, and the message persists, call Service. 306 The pod may have been opened and not closed properly when scanning was attempted. • Be sure the pod is completely closed. 143, 543, Informational message. The scanner was unable to find the 943 document edges to determine the skew angle. • The document is too dark. • The image is too large. 46, 446, 846 The scanned document was too long to rotate. Scanning was stopped. • Locate this document and rescan it with a lower resolution or with Rotation turned off. 297 • There is too much paper in the elevator tray and it is holding the feed module up. The elevator tray capacity is 500 sheets. Remove some documents from the elevator tray. • The feed module is not installed properly. See Chapter 5, Maintenance, for correct installation procedures. • If the problem persists, call Service. 6-6 A-61500 April 2007