Regular adjustment flow High accuracy
View all Konica Minolta bizhub PRESS C71hc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Regular adjustment flow (High accuracy) )Adjustment timing For customers that require a high accuracy color reproduction, conduct the process 30 minutes after you activate the power every day. For other cases, conduct the process in the following cases. - Before you output a job that the color is important - When you are not satisfied with the color stability (want to improve the reproducibility) )Adjustment order Order Adjustment item 1 Gamma Automatic Adjustment 2 Maximum Density Adjustment 3 IC-602 Controller Calibration Required time Approximately 1 minute Approximately 15 minutes Approximately 5 minute Reference P.3-7 P.3-27 (for i1Pro/i1Pro2/ES1000/ES-2000) P.3-36 (for FD-5BT) P.3-41 Tips If you interrupted the operation during the adjustment flow, be sure to perform Gamma Automatic Adjustment before the rest of adjustment flow. Reference For details of each adjustment item, refer to "Contents of the image quality adjustment items" (Page 3-5). 3-2