Konica Minolta bizhub PRESS C71hc bizhub PRESS C1060/C1070/C1070P/PRO C1060L D - Page 85

On the [Calibration Manager] screen

Page 85 highlights

12 On the [Calibration Manager] screen, click [Accuracy Measurement] under [3. G7 Calibration]. bizhub PRESS C1070/C1070P/C1060 bizhub PRO C1060L 13 Click [Print]. Print the color chart that is to be measured using the instrument. 14 Click [Start]. 15 Measure the chart using the instrument. After you finish the chart measurement, click [OK]. NOTICE When the values of 'Ch and 'E* are not G7 standard as the result of the accuracy check, the dialogue is displayed. You can choose to recalculate and register the calibration table to fit in the target range or register as is in the dialogue. Conduct the recalculation. If you recalculate and the values of 'Ch and 'E* are still not G7 standard, check the following adjustment items. - Gamma automatic adjustment - Density balance adjustment - Maximum Density Adjustment - IC-602 Controller Calibration 3 3-53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117

3-53
bizhub PRO C1060L
bizhub PRESS C1070/C1070P/C1060
3
12
On the [Calibration Manager] screen,
click [Accuracy Measurement] under [3.
G7 Calibration].
13
Click [Print].
Print the color chart that is to be measured using
the instrument.
14
Click [Start].
15
Measure the chart using the instrument.
After you finish the chart measurement,
click [OK].
NOTICE
When the values of
'
Ch and
'
E* are not G7 standard as
the result of the accuracy check, the dialogue is
displayed. You can choose to recalculate and register the
calibration table to fit in the target range or register as is
in the dialogue. Conduct the recalculation.
If you recalculate and the values of
'
Ch and
'
E* are still
not G7 standard, check the following adjustment items.
- Gamma automatic adjustment
- Density balance adjustment
- Maximum Density Adjustment
- IC-602 Controller Calibration