Konica Minolta bizhub PRESS C71hc bizhub PRESS C1060/C1070/C1070P/PRO C1060L D - Page 88

Regular adjustment flow High accuracy, Adjustment flow when using a new type of paper

Page 88 highlights

Regular adjustment flow (High accuracy) )Adjustment timing For customers that require a high accuracy color reproduction, conduct the process 30 minutes after you activate the power every day. For other cases, conduct the process in the following cases. - Before you output a job that the color is important - When you are not satisfied with the color stability (want to improve the reproducibility) )Adjustment order Order 1 2 3 Adjustment item Gamma Automatic Adjustment Maximum Density Adjustment (for i1Pro/i1Pro2/ES-1000/ES-2000) IC-308/IC-415 Controller Calibration Required time Approximately 1 minute Approximately 15 minutes Approximately 5 minutes Reference P.3-60 P.3-72 P.3-81 Tips If you interrupted the operation during the adjustment flow, be sure to perform Gamma Automatic Adjustment before the rest of adjustment flow. Reference For details of each adjustment item, refer to "Contents of the image quality adjustment items" (Page 3-58). Adjustment flow when using a new type of paper )Adjustment timing - When you use a new type of paper - When the color is not reproduced even though regular adjustment flow (high accuracy) is performed )Adjustment order Order 1 2 3 Adjustment item Gamma Automatic Adjustment Density Balance Adjustment * (for i1Pro/i1Pro2/ES-1000/ES-2000) IC-308/IC-415 Controller Calibration Required time Approximately 1 minute Approximately 10 minutes Approximately 5 minutes * When the screen is [Stochastic], Density balance adjustment is not required. Reference P.3-60 P.3-61 P.3-81 Tips If you interrupted the operation during the adjustment flow, be sure to perform Gamma Automatic Adjustment before the rest of adjustment flow. Reference For details of each adjustment item, refer to "Contents of the image quality adjustment items" (Page 3-58). 3-56

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117

3-56
Regular adjustment flow (High accuracy)
)
Adjustment timing
For customers that require a high accuracy color reproduction, conduct the process 30 minutes after you activate the
power every day.
For other cases, conduct the process in the following cases.
-
Before you output a job that the color is important
-
When you are not satisfied with the color stability (want to improve the reproducibility)
)
Adjustment order
Tips
If you interrupted the operation during the adjustment flow, be sure to perform Gamma Automatic Adjustment before
the rest of adjustment flow.
Reference
For details of each adjustment item, refer to "Contents of the image quality adjustment items" (
Page 3-58
).
Adjustment flow when using a new type of paper
)
Adjustment timing
-
When you use a new type of paper
-
When the color is not reproduced even though regular adjustment flow (high accuracy) is performed
)
Adjustment order
* When the screen is [Stochastic], Density balance adjustment is not required.
Tips
If you interrupted the operation during the adjustment flow, be sure to perform Gamma Automatic Adjustment before
the rest of adjustment flow.
Reference
For details of each adjustment item, refer to "Contents of the image quality adjustment items" (
Page 3-58
).
Order
Adjustment item
Required time
Reference
1
Gamma Automatic Adjustment
Approximately
1 minute
P.3-60
2
Maximum Density Adjustment
(for i1Pro/i1Pro2/ES-1000/ES-2000)
Approximately
15 minutes
P.3-72
3
IC-308/IC-415 Controller Calibration
Approximately
5 minutes
P.3-81
Order
Adjustment item
Required time
Reference
1
Gamma Automatic Adjustment
Approximately
1 minute
P.3-60
2
Density Balance Adjustment *
(for i1Pro/i1Pro2/ES-1000/ES-2000)
Approximately
10 minutes
P.3-61
3
IC-308/IC-415 Controller Calibration
Approximately
5 minutes
P.3-81