The calibration table is registered in the image
View all Konica Minolta bizhub PRESS C71hc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
12 Click [Next] and perform the rest of the measurement by following the instructions on the screen. Perform the rest of the measurement with the same procedures, in order of "2. The 1st enhancement of a correction table (FB1)", "3. The 2nd enhancement of a correction table (FB2)", "4. The 3rd enhancement of a correction table (FB3)", and "5. The accuracy measurement of FB3". 13 After the measurement of the "5. The accuracy measurement of FB3", click [OK] on [Operation steps] screen. bizhub PRESS C1070/C1070P/C1060 bizhub PRO C1060L 14 Change the measurement number on the right side of [Select] and check the ['E Ave], ['E Max] values, and the ['a] ['b] graph of the Gray displayed within the [Gray Step] frame. As for the Gray, check the information within the [Gray Step] frame and select the calibration data that has the smallest difference from the target. Then click [Register the selected result.] . Tips - When you put a priority on the gray reproducibility of the low density, check the left half of the ['a] ['b] graph that is displayed within the [Gray Step] frame. And select the calibration data that ['a] and ['b] values are close to "0". - When you put a priority on the gray reproducibility of the high density, check the right half of the ['a] ['b] graph that is displayed within the [Gray Step] frame. And select the calibration data that ['a] and ['b] values are close to "0". 15 Click [OK] on the [Information] screen. The calibration table is registered in the image controller. 3 3-49