Konica Minolta bizhub PRO 1100 bizhub PRO 1100 Daily Maintenance Guide - Page 40

Adjustment], and [FD-Mag. Adjustment]

Page 40 highlights

)FD-Mag. Adjustment (Side 2) Adjust the magnification in paper feed direction in the printer engine. This adjustment value will be the standard for Both Sides Adjust in Paper Setting. Objects of adjustment: Tray 1 to Tray 5, Bypass Tray 1 Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. 2 Press [Machine Adjustment], [Printer Adjustment], and [FD-Mag. Adjustment] in sequence. 3 Press [Side 2]. Press the tray with the target paper loaded. 4 Press [Print Mode]. 5 Load A3 w paper or 11 e 17 w paper into the tray to be adjusted, then select that tray. 6 Press Start on the control panel. A sample pattern will be output. 7 Measure the resultant magnification in the paper feed direction. Allowance: r 0.5% or less (full size) Within 205.7 mm r 1 mm 205.7 2-14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

2-14
)
FD-Mag. Adjustment (Side 2)
Adjust the magnification in paper feed direction in the printer engine. This adjustment value will be the standard for
Both Sides Adjust in Paper Setting.
Objects of adjustment: Tray 1 to Tray 5, Bypass Tray
1
Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu]
screen.
2
Press [Machine Adjustment], [Printer
Adjustment], and [FD-Mag. Adjustment]
in sequence.
3
Press [Side 2].
Press the tray with the target paper loaded.
4
Press [Print Mode].
5
Load A3
w
paper or 11
e
17
w
paper into the tray to be adjusted, then select that tray.
6
Press
Start
on the
control panel
.
A sample pattern will be output.
7
Measure the resultant magnification in
the paper feed direction.
Allowance:
r
0.5% or less (full size)
Within 205.7 mm
r
1 mm
205.7