Place the background sheet on the, then close the, Press [Start] on the [Scan Adjustment, Chart]

Page 53 highlights

bizhub PRO 1100 13 Place the background sheet on the original glass, then close the ADF. Place the black side of the background sheet facing down (facing the original glass), then set it flush with the vertical size guide and horizontal size guide as shown below. Exercise care to ensure the previously set adjustment chart is not misaligned. 14 Press [Start] on the [Scan Adjustment Chart] screen. The adjustment chart is scanned. When scanning is properly completed, the counter of [Number of Scanning] on the Scan Adjustment Chart screen is added by one, and the blue frame displayed in the illustration on the screen shifts to the next one on the right side. - If you move the adjustment chart before the blue frame shifts to the next, the measurement may not be performed properly. - If the ADF is open, scanning fails, and a message is displayed. Close the ADF, then press [Close] in the message dialog box. - If scanning fails, a message may be displayed. Follow the on-screen instructions to correctly place the adjustment chart and background sheet, then press [Close]. - If you press [Return] on the Scan Adjustment Chart screen during scan measurement, a message is displayed to confirm whether to interrupt the scan measurement. To discard the previous measurement result, press [Yes]. Retry the scanning process from the first scan measurement. When continuing scan measurement, press [No]. 2 2-27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

2-27
bizhub PRO 1100
2
13
Place the background sheet on the
original glass
, then close the
ADF
.
Place the black side of the background sheet facing down (facing the
original glass
), then set it flush
with the
vertical size guide
and
horizontal size guide
as shown below. Exercise care to ensure the
previously set adjustment chart is not misaligned.
14
Press [Start] on the [Scan Adjustment
Chart] screen.
The adjustment chart is scanned.
When scanning is properly completed, the
counter of [Number of Scanning] on the Scan
Adjustment Chart screen is added by one, and
the blue frame displayed in the illustration on
the screen shifts to the next one on the right
side.
-
If you move the adjustment chart before the
blue frame shifts to the next, the
measurement may not be performed
properly.
-
If the
ADF
is open, scanning fails, and a
message is displayed. Close the
ADF
, then
press [Close] in the message dialog box.
-
If scanning fails, a message may be
displayed. Follow the on-screen instructions
to correctly place the adjustment chart and
background sheet, then press [Close].
-
If you press [Return] on the Scan Adjustment
Chart screen during scan measurement, a
message is displayed to confirm whether to
interrupt the scan measurement. To discard
the previous measurement result, press [Yes].
Retry the scanning process from the first scan