Konica Minolta bizhub PRO 1100 bizhub PRO 1100 Daily Maintenance Guide - Page 58

Select [Gap], then press [Print Mode].

Page 58 highlights

4 Select [Gap], then press [Print Mode]. 5 When the [PRINT MODE] screen is displayed, press Start on the control panel. A test chart is printed out. 6 Press [Exit Print Mode]. 7 Measure the gap between the front and back sides at each point of [a] to [d] on the [back] side of the printed out chart. [a] - This figure shows an example to measure [a]. The scale resolution is 0.5 mm. back - In this figure, the black line indicates the front side, and the blue line indicates the back side. - The measurement value can be entered in - units of up to 0.1 mm. - For example, as shown in the figure, if the scale of [a] is misaligned 1.5 mm in the plus side compared with the front side, press [1] - [5] - [+/-] to enter "-1.5" as the adjustment value. Then, the blue line on the back side will be moved 1.5 mm toward the minus side. - Write down the measured values so that you do not forget them. 2-32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

2-32
4
Select [Gap], then press [Print Mode].
5
When the [PRINT MODE] screen is
displayed, press
Start
on the
control
panel
.
A test chart is printed out.
6
Press [Exit Print Mode].
7
Measure the gap between the front and
back sides at each point of [a] to [d] on
the [back] side of the printed out chart.
-
This figure shows an example to measure [a].
The scale resolution is 0.5 mm.
-
In this figure, the black line indicates the front
side, and the blue line indicates the back side.
-
The measurement value can be entered in
-
units of up to 0.1 mm.
-
For example, as shown in the figure, if the
scale of [a] is misaligned 1.5 mm in the plus
side compared with the front side, press [1] -
[5] - [+/-] to enter "-1.5" as the adjustment
value. Then, the blue line on the back side will
be moved 1.5 mm toward the minus side.
-
Write down the measured values so that you
do not forget them.
back
[a]