LG ARUB115BT2 Installation Manual - Page 75

Self-Diagnosis Function

Page 75 highlights

ENGLISH Test Run Self-Diagnosis Function Error Indicator • This function indicates types of failure in self-diagnosis and occurrence of failure for air condition. • Error mark is displayed on display window of indoor units and wired remote controller, and 7-segment LED of outdoor unit control board as shown in the table. • If more than two troubles occur simultaneously, lower number of error code is first displayed. • After error occurrence, if error is released, error LED is also released simultaneously. Error Display 1st,2nd LED of 7-segment indicates error number, 3rd LED indicates unit number. Ex) 211 : No.21 error of master unit 213 : No.21 error of slave 011 ¡ 051 : No.105 error of master unit Indoor unit related error Display Title Cause of Error 0 1 - Air temperature sensor of indoor unit Air temperature sensor of indoor unit is open or short 0 2 - Inlet pipe temperature sensor of indoor unit Inlet pipe temperature sensor of indoor unit is open or short 0 3 - Communication error : wired remote controller ↔ indoor unit Failing to receive wired remote controller signal in indoor unit PCB 0 4 - Drain pump 0 5 - Communication error : outdoor unit ↔ indoor unit Malfunction of drain pump Failing to receive outdoor unit signal in indoor unit PCB 0 6 - Outlet pipe temperature sensor of indoor unit Outlet pipe temperature sensor of indoor unit is open or short 0 7 - Different operation mode Operation mode between indoor unit and outdoor unit is different 0 9 - Serial No. In case when the serial number marked on EEPROM of Indoor unit is 0 or FFFFFF 1 0 - Poor fan motor operation Disconnecting the fan motor connector/Failure of indoor fan motor lock 1 1 - Communication error: indoor unit When the addressing signal doesn't respond for 3mins. suddenly, ¡ main PCB of outdoor. while the indoor unit gets the calling signal from the outdoor unit, 1 Master Outdoor Unit Inverter 21 Compressor IPM Fault 2 slave Outdoor Unit Inverter Compressor IPM Fault Inverter Board Input Over 1 Current(RMS) of Master Outdoor 22 Unit Inverter Board Input Over 2 Current(RMS) of slave Outdoor Unit Master Outdoor Unit Inverter Compressor Drive IPM Fault slave Outdoor Unit Inverter Compressor Drive IPM Fault Master Outdoor Unit Inverter Board Input Current excess (RMS) slave Outdoor Unit Inverter Board Input Current excess (RMS) Outdoor unit related error 2 3 1 Master Outdoor Unit Inverter Compressor DC link Low Voltage DC charging is not performed at Master outdoor unit after starting relay turn on. 2 slave Outdoor Unit Inverter Compressor DC link Low Voltage DC charging is not performed at slave outdoor unit after starting relay turn on. 2 4 1 Master Outdoor Unit High Pressure Switch System is turned off by Master outdoor unit high pressure switch. 2 slave Outdoor Unit High Pressure Switch System is turned off by slave outdoor unit high pressure switch. Installation Manual 75

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83

Installation Manual
75
ENGLISH
Test Run
DC charging is not performed at Master outdoor unit
after starting relay turn on.
DC charging is not performed at slave outdoor unit
after starting relay turn on.
System is turned off by Master outdoor unit high pres-
sure switch.
System is turned off by slave outdoor unit high pres-
sure switch.
Master Outdoor Unit Inverter
Compressor DC link Low Voltage
slave Outdoor Unit Inverter
Compressor DC link Low Voltage
Master Outdoor Unit High
Pressure Switch
slave Outdoor Unit High Pressure
Switch
1
2
3
2
1
2
4
2
Self-Diagnosis Function
Error Indicator
This function indicates types of failure in self-diagnosis and occurrence of failure for air condition.
Error mark is displayed on display window of indoor units and wired remote controller, and 7-segment LED of
outdoor unit control board as shown in the table.
If more than two troubles occur simultaneously, lower number of error code is first displayed.
After error occurrence, if error is released, error LED is also released simultaneously.
Error Display
1st,2nd LED of 7-segment indicates error number, 3rd LED indicates unit number.
Ex) 211 : No.21 error of master unit
213 : No.21 error of slave
011
051 : No.105 error of master unit
Display
Title
Cause of Error
0
1
-
0
2
-
0
3
-
0
4
-
0
5
-
0
6
-
0
7
-
0
9
-
1
0
-
1
1
-
2
1
1
2
1
2
2
2
Air temperature sensor of indoor unit
Inlet pipe temperature sensor of indoor unit
Communication error : wired
remote controller
indoor unit
Drain pump
Communication error : outdoor
unit
indoor unit
Outlet pipe temperature sensor of
indoor unit
Different operation mode
Serial No.
Poor fan motor
operation
Communication
error: indoor unit
main PCB of outdoor.
Master Outdoor Unit Inverter
Compressor IPM Fault
slave Outdoor Unit Inverter
Compressor IPM Fault
Inverter Board Input Over
Current(RMS) of Master Outdoor
Unit
Inverter Board Input Over
Current(RMS) of slave Outdoor
Unit
Air temperature sensor of indoor unit is open or short
Inlet pipe temperature sensor of indoor unit is open or short
Failing to receive wired remote controller signal in
indoor unit PCB
Malfunction of drain pump
Failing to receive outdoor unit signal in indoor unit PCB
Outlet pipe temperature sensor of indoor unit is
open or short
Operation mode between indoor unit and outdoor unit
is different
In case when the serial number marked on
EEPROM of Indoor unit is 0 or FFFFFF
Disconnecting
the fan motor connector/Failure of indoor fan
motor lock
When the addressing signal doesn't respond for 3mins. suddenly,
while the indoor unit gets the calling signal from the outdoor unit,
Master Outdoor Unit Inverter Compressor Drive IPM Fault
slave Outdoor Unit Inverter Compressor Drive IPM Fault
Master Outdoor Unit Inverter Board Input Current
excess (RMS)
slave Outdoor Unit Inverter Board Input Current excess
(RMS)
Indoor unit related error
Outdoor unit related error