Lenovo ThinkCentre A58e Hardware Maintenance Manual - Page 53

FRU/Action, BIOS APM failure

Page 53 highlights

Diagnostic error code 000-250-XXX BIOS APM failure 000-270-XXX BIOS ACPI failure 001-000-XXX System test passed 001-00X-XXX System error 001-01X-XXX System error 001-024-XXX System addressing test failure 001-025-XXX System checksum value error 001-026-XXX System FLASH data error 001-027-XXX System configuration/setup error 001-032-XXX System device controller failure 001-034-XXX System device buffer allocation failure 001-035-XXX System device reset condition detected 001-036-XXX System register error 001-038-XXX System extension failure 001-039-XXX System DMI data structure error 001-040-XXX System IRQ failure 001-041-XXX System DMA failure 001-195-XXX System test aborted by user 001-196-XXX System test halt, error threshold exceeded FRU/Action 1. Flash the system. See "Updating (flashing) BIOS from a disc" on page 99 2. System board 1. Flash the system. See "Updating (flashing) BIOS from a disc" on page 99 2. System board No action System board System board System board 1. Flash the system. See "Updating (flashing) BIOS from a disc" on page 99 2. System board 1. Flash the system. See "Updating (flashing) BIOS from a disc" on page 99 2. System board 1. Run Setup 2. Flash the system. See "Updating (flashing) BIOS from a disc" on page 99 3. System board System board 1. Reboot the system 2. Flash the system. See "Updating (flashing) BIOS from a disc" on page 99 3. Run memory test 4. System board System board System board 1. Adapter card 2. System board 1. Flash the system. See "Updating (flashing) BIOS from a disc" on page 99 2. System board 1. Power-off/on system and re-test 2. System board 1. Power-off/on system and re-test 2. System board Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file Chapter 7. Symptom-to-FRU index 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

Diagnostic error code
FRU/Action
000-250-XXX
BIOS APM failure
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
000-270-XXX
BIOS ACPI failure
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
001-000-XXX
System test passed
No action
001-00X-XXX
System error
System board
001-01X-XXX
System error
System board
001-024-XXX
System addressing test failure
System board
001-025-XXX
System checksum value error
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
001-026-XXX
System FLASH data error
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
001-027-XXX
System configuration/setup error
1. Run Setup
2. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
3. System board
001-032-XXX
System device controller failure
System board
001-034-XXX
System device buffer allocation failure
1. Reboot the system
2. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
3. Run memory test
4. System board
001-035-XXX
System device reset condition detected
System board
001-036-XXX
System register error
System board
001-038-XXX
System extension failure
1. Adapter card
2. System board
001-039-XXX
System DMI data structure error
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
001-040-XXX
System IRQ failure
1. Power-off/on system and re-test
2. System board
001-041-XXX
System DMA failure
1. Power-off/on system and re-test
2. System board
001-195-XXX
System test aborted by user
Information only Re-start the test, if necessary
001-196-XXX
System test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 7
.
Symptom-to-FRU index
47