Lexmark Optra E Service Manual - Page 44
Low Voltage Power Supply Service Check, Dead Printer
View all Lexmark Optra E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
4026-0XX Low Voltage Power Supply Service Check Note: The controller board, HVPS and printhead assembly receive power from the LVPS through the engine board. If the machine is dead, be sure the controller board is correctly seated in the engine board connector. Check and reseat all cables. Dead Printer FRU Action 1 Line Voltage Check the AC line voltage. The voltages should be within the following limits: 100 V ac (90 V ac - 110 V ac) Japan 120 V ac (108 V ac - 132 V ac) U.S. 220/230 V ac (207 V ac - 253 V ac) W.T. 2 LVPS The voltage measures approximately +5 V dc between CN7-4 and ground on the engine board. If incorrect, disconnect CN7 on the engine board and measure the voltage between CN7-4 (+5 V dc) and CN7-3 (+5 V ground). The reading should measure approximately +5 V dc. If +5 V dc is not present, unplug the printer line cord and check fuse F1. If the fuse is open, replace the fuse. If the fuse is not open, replace the LVPS. 3 Engine Board If +5 V dc is present when CN7 is disconnected then disconnect CN2, CN4, CN5, CN9 and CN10 from the engine board. Also disconnect the controller board and remove the ROM SIMM and any optional memory SIMMs. Reconnect CN7 and check for +5 V dc. If incorrect, replace the engine board. 4 Controller Reinstall the controller board. Check for +5 V dc Board at CN7-4. If incorrect, replace the controller board. 2-22