LiftMaster EL2000 EL25-KEYPAD PROGRAMMING Manual - Page 47

Add or Edit a Full Function Transmitter: 91, Factory Settings, Full Access, Activate

Page 47 highlights

Add or Edit a Full Function Transmitter: 91 Add or edit a full function transmitter. When adding a Full Function transmitter, it will default as "active". To deactivate a transmitter, or to activate or deactivate on a specific time and date, see Activate or Deactivate Transmitter (page 48). Factory Settings: All Doors = 1 Full Access 1 Press Then 2 Enter Transmitter Number (1-65534). Then (#) 3 Enter Facility Code (0-255). Then (#) 4 Enter Sequence Code (0-2). Then (#) 5 Enter ID Number (0-26). Then (#) 6 Enter Button Number (1-4). Then (#) 7 Schedule for Door 1 (1-4). Then (#) 0=Full Restrictions 1=Full Access 8 Schedule for Door 2 (1-4). Then (#) 0=Full Restrictions 1=Full Access 9 Schedule for Door 3 (1-4). Then (#) 0=Full Restrictions 1=Full Access 10 Schedule for Door 4 (1-4). Then (#) 0=Full Restrictions 1=Full Access Add or Edit a Group of Full Function Transmitters: 94 Add a large number of transmitters at once to the system. The individual transmitters can be edited later. Factory Settings: Activate or Deactivate = 1 Activate; All Doors = 1 Full Access • Group transmitters must have the same Facility Code, Sequence Code, ID Number and Active Button. 1 Press Then 2 Enter Starting Transmitter Number (1-65534). Then (#) 3 Enter Ending Transmitter Number (1-65534). Then (#) 4 Enter Facility Code (0-2545). Then (#) 5 Enter Sequence Code (0-2). Then (#) 6 Enter ID Number (0-26). Then (#) 7 Enter Button Number (1-4). Then (#) 8 Activate (1) or Deactivate (0). Then (#) 9 Schedule for Door 1 (1-4). Then (#) 0=Full Restrictions 1=Full Access 10 Schedule for Door 2 (1-4). Then (#) 0=Full Restrictions 1=Full Access 11 Schedule for Door 3 (1-4). Then (#) 0=Full Restrictions 1=Full Access 12 Schedule for Door 4 (1-4). Then (#) 0=Full Restrictions 1=Full Access Transmitters Transmitters Page 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Page 46
Transmitters
Transmitters
Add or Edit a Full Function Transmitter:
1
Press
Then
2
Enter Transmitter Number (1-65534). Then (#)
3
Enter Facility Code (0-255). Then (#)
4
Enter Sequence Code (0-2). Then (#)
5
Enter ID Number (0-26). Then (#)
6
Enter Button Number (1-4). Then (#)
Add or edit a full function transmitter. When adding a
Full Function
transmitter, it will default
as
"
active
"
. To deactivate a transmitter, or to activate or deactivate on a specific time and
date, see
Activate or Deactivate Transmitter
(page 48).
Factory Settings:
All Doors =
1 Full Access
7
Schedule for Door 1 (1-4). Then (#)
0
=Full Restrictions
1
=Full Access
8
Schedule for Door 2 (1-4). Then (#)
0
=Full Restrictions
1
=Full Access
9
Schedule for Door 3 (1-4). Then (#)
0
=Full Restrictions
1
=Full Access
10
Schedule for Door 4 (1-4). Then (#)
0
=Full Restrictions
1
=Full Access
Add or Edit a Group of Full Function Transmitters:
1
Press
Then
2
Enter Starting Transmitter Number (1-65534).
Then (#)
3
Enter Ending Transmitter Number (1-65534).
Then (#)
4
Enter Facility Code (0-2545). Then (#)
5
Enter Sequence Code (0-2). Then (#)
6
Enter ID Number (0-26). Then (#)
7
Enter Button Number (1-4). Then (#)
Add a large number of transmitters at once to the system. The individual transmitters can be
edited later.
Factory Settings:
Activate or Deactivate =
1 Activate;
All Doors =
1 Full Access
Group transmitters must have the same Facility Code, Sequence Code, ID Number and
Active Button.
8
Activate (
1
) or Deactivate (
0
). Then (#)
9
Schedule for Door 1 (1-4). Then (#)
0
=Full Restrictions
1
=Full Access
10
Schedule for Door 2 (1-4). Then (#)
0
=Full Restrictions
1
=Full Access
11
Schedule for Door 3 (1-4). Then (#)
0
=Full Restrictions
1
=Full Access
12
Schedule for Door 4 (1-4). Then (#)
0
=Full Restrictions
1
=Full Access
94
91