Sony DCR-TRV10 Service Manual - Page 109

Optical Axis Adjustment, Display phase, Correction data

Page 109 highlights

7. Optical Axis Adjustment Align the lens Optical Axis with the that of the CCD imager. If deviated, center of picture can lose focus when zoom is operated from the WIDE end to the TELE end. Subject Siemens star Measurement Point Check on the monitor TV Measuring Instrument Adjustment Page F Adjustment Address 43 Switch setting: 1) NIGHT SHOT OFF Preparations before adjustments: 1) Playback the monoscope segment of the system check tape (XH5-5 (NTSC), XH5-5P (PAL)). 2) Attach the optical axis frame chart (transparent) on the monitor TV screen. Center of monoscope image and that that of optical axis frame must be agree. 3) Set to the camera mode. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 6, address: 40, and set data: 02. 3) Select page: 6, address: 41, and set data: 01. 4) Select page: F, address: 43, set data: 00, and press the PAUSE button of the adjustment remote commander. 5) Place the Siemens star 2.0 m away from the front of the lens. 6) Shoot the Siemens star with the zoom TELE end. 7) Point the lens toward the Siemens star chart until center of the Siemens star is located in the center of the optical axis frame. 8) Shoot the Siemens star with the zoom WIDE end. 9) Measure on the monitor TV screen in which area of the optical axis frame the center of the Siemens star is located. Measure the amount of displacement (distance between the center of the Siemens star and the center of the optical axis frame.) The measurement value is named L1. 10) Read the correction data corresponding to the area from the following table. Area 1 2 3 4 5 6 7 8 Display phase 22.6° to 67.5° 67.6° to 112.5° 112.6° to 157.5° 157.6° to 202.5° 202.6° to 247.5° 247.6° to 292.5° 292.6° to 337.5° 337.6° to 22.5° Correction data 01 02 03 04 05 06 07 08 11) Set the correction data to page: F, address: 43 and press the PAUSE button. 12) Shoot the Siemens star with the zoom TELE end. 13) Point the lens toward the Siemens star chart until center of the Siemens star is located in the center of the optical axis frame. 14) Shoot the Siemens star with the zoom WIDE end. 15) Measure the amount of displacement (distance between the center of the Siemens star and the center of the optical axis frame.) The measurement value is named L2. 16) Compare the values L1 and L2, and confirm that L2 is smaller than L1. If L2 is lager than L1, select page F, address 43 and set data: 00, and press the PAUSE button. Processing after Completing Adjustments: 1) Select page: 0, address: 01, and set data: 00. 2) Select page: 6, address: 40, and set data: 00. 3) Select page: 6, address: 41, and set data: 00. 5-23 Fig. 5-1-7.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

5-23
7. Optical Axis Adjustment
Align the lens Optical Axis with the that of the CCD imager. If
deviated, center of picture can lose focus when zoom is operated
from the WIDE end to the TELE end.
Subject
Siemens star
Measurement Point
Check on the monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
43
Switch setting:
1)
NIGHT SHOT
..................................................................
OFF
Preparations before adjustments:
1)
Playback the monoscope segment of the system check tape
(XH5-5 (NTSC), XH5-5P (PAL)).
2)
Attach the optical axis frame chart (transparent) on the monitor
TV screen. Center of monoscope image and that that of optical
axis frame must be agree.
3)
Set to the camera mode.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 40, and set data: 02.
3)
Select page: 6, address: 41, and set data: 01.
4)
Select page: F, address: 43, set data: 00, and press the PAUSE
button of the adjustment remote commander.
5)
Place the Siemens star 2.0 m away from the front of the lens.
6)
Shoot the Siemens star with the zoom TELE end.
7)
Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
8)
Shoot the Siemens star with the zoom WIDE end.
9)
Measure on the monitor TV screen in which area of the optical
axis frame the center of the Siemens star is located. Measure
the amount of displacement (distance between the center of
the Siemens star and the center of the optical axis frame.) The
measurement value is named L1.
10)
Read the correction data corresponding to the area from the
following table.
11)
Set the correction data to page: F, address: 43 and press the
PAUSE button.
12)
Shoot the Siemens star with the zoom TELE end.
13)
Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
14)
Shoot the Siemens star with the zoom WIDE end.
15)
Measure the amount of displacement (distance between the
center of the Siemens star and the center of the optical axis
frame.) The measurement value is named L2.
16)
Compare the values L1 and L2, and confirm that L2 is smaller
than L1. If L2 is lager than L1, select page F, address 43 and
set data: 00, and press the PAUSE button.
Processing after Completing Adjustments:
1)
Select page: 0, address: 01, and set data: 00.
2)
Select page: 6, address: 40, and set data: 00.
3)
Select page: 6, address: 41, and set data: 00.
Fig. 5-1-7.
Area
1
2
3
4
5
6
7
8
Display phase
22.6
°
to 67.5
°
67.6
°
to 112.5
°
112.6
°
to 157.5
°
157.6
°
to 202.5
°
202.6
°
to 247.5
°
247.6
°
to 292.5
°
292.6
°
to 337.5
°
337.6
°
to 22.5
°
Correction data
01
02
03
04
05
06
07
08