Sony DCR-TRV10 Service Manual - Page 121
Mechanism Adjustment, How To Enter Record Mode Without, Cassette
View all Sony DCR-TRV10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
5-2. MECHANISM SECTION ADJUSTMENT On the mechanism section adjustment For details of mechanism section adjustments, checks, and replacement of mechanism parts, refer to the separate volume "DV MECHANICAL ADJUSTMENT MANUAL D Mechanism "and "MECHANICAL ADJUSTMENT MANUAL D200 Mechanism ". 2-1. HOW TO ENTER RECORD MODE WITHOUT CASSETTE 1) Connect the adjustment remote commander to the LANC jack. 2) Turn the HOLD switch of the adjustment remote commander to the ON position. 3) Close the cassette compartment without the cassette. 4) Select page: 3, address: 01, set data: 0C, and press the PAUSE button of the adjustment remote commander. (The mechanism enters the record mode automatically.) Note: The function buttons become inoperable. 5) To quit the record mode, select page: 3, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. (Whenever you want to quit the record mode, be sure to quit following this procedure.) 2-2. HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE 1) Connect the adjustment remote commander to the LANC jack. 2) Turn the HOLD switch of the adjustment remote commander to the ON position. 3) Close the cassette compartment without the cassette. 4) Select page: 3, address: 01, set data: 0B, and press the PAUSE button of the adjustment remote commander. (The mechanism enters the playback mode automatically.) Note: The function buttons become inoperable. 5) To quit the playback mode, select page: 3, address: 01, set data: 00, and press the PAUSE button of the adjustment remote commander. (Whenever you want to quit the playback mode, be sure to quit following this procedure.) 2-3. TAPE PATH ADJUSTMENT 1. Preparation for Adjustment 1) Clean the tape running side (tape guide, drum, capstan shaft, pinch roller, etc.). 2) Connect the adjustment remote commander to the LANC jack. 3) Turn the HOLD switch of the adjustment remote commander to the ON position. 4) Connect an oscilloscope to VC-217 board CN2904 via the CPC- 8 jig (J-6082-388-A). Channel 1: VC-217 board, CN2904 Pin @º (Note) External trigger: VC-217 board, CN2904 Pin !¶ Note: Connect a 75 Ω resistor between pins @º of CN2904 and !ª (GND). 75 Ω resistor (Parts code: 1-247-804-11) 5) Playback the alignment tape for tracking. (XH2-1) 6) Select page: 3, address: 33, and set data: 08. 7) Select page: 3, address: 26, and set data: 31. 8) Check that the oscilloscope RF waveform is flat at the entrance and exit. If not flat, adjust according to the separate volume "DV MECHANICAL ADJUSTMENT MANUAL D Mechanism " and "MECHANICAL ADJUSTMENT MANUAL D200 Mechanism ". CN2904 of VC-217 board Pin No. Signal Name 1 LACN SIG 3 EVF BL- 5 EVF VCO 7 PD VG 9 H START 11 PANEL COM 13 TCK 15 TDO 17 SWP 19 GND Pin No. 2 4 6 8 10 12 14 16 18 20 Signal Name EVF BL+ EVF VG GND PD VCO XHD/PSIG TMS TDI GND RF IN/LANC JACK IN RF MON 2. Procedure after operations 1) Connect the adjustment remote commander to the LANC jack and set the HOLD switch to the ON position. 2) Select page: 3, address: 26, and set data: 00. 3) Select page: 3, address: 33, and set data: 00. CH1 Must be flat CH2 (Trigger) 5-35 3.3msec Fig. 5-2-1.