Sony DCR-TRV10 Service Manual - Page 145
CAM MODE SW PS-4550 block S1, START/STOP SW PS-4550 block S2
View all Sony DCR-TRV10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
3. Bit value discrimination Bit values must be discriminated using the display data of the adjustment remote commander for following items. Use the table below to discriminate if the bit value is "1" or "0". Display on the adjustment remote commander Page Address bit3 to bit0 discrimination bit7 to bit4 discrimination Display on the Bit values adjustment bit3 bit2 bit1 bit0 remote or or or or commander bit7 bit6 bit5 bit4 0 0 0 0 0 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 4 0 1 0 0 5 0 1 0 1 6 0 1 1 0 7 A 8 0 1 1 1 1 0 0 0 9 1 0 0 1 A (A) 1 0 1 0 B (b) 1 0 1 1 C (c) 1 1 0 0 D (d) 1 1 0 1 B E (E) 1 1 1 0 F (F) 1 1 1 1 Example: If "8E" is displayed on the adjustment remote commander, the bit values for bit7 to bit4 are shown in the A column, and the bit values for bit3 to bit0 are shown in the B column. 4. Switch check (1) Page 2 Address 43 Bit Function 0 VTR MODE SW (PS-4550 block S1) 1 CAM MODE SW (PS-4550 block S1) 2 START/STOP SW (PS-4550 block S2) 3 EJECT SW (FP-85 flexbile S61) 4 CC DOWN SW (Mechanism chassis) 5 PHOTO FREEZE SW (FP-85 flexible S71) 6 PHOTO STBY SW (PS-4550 block S1) 7 When bit value=1 When bit value=0 OFF ON OFF ON OFF ON OFF ON OFF (UP) ON (DOWN) OFF ON OFF ON Using method: 1) Select page: 2, address: 43. 2) By discriminating the bit value of display data, the state of the switch can be discriminated. 5-59